PDS_VERSION_ID = "PDS3" RECORD_TYPE = STREAM FILE_RECORDS = 8185 PRODUCT_ID = "SMCRAT_SPECTRA" PRODUCT_VERSION_ID = "V1" PRODUCT_CREATION_TIME = 2014-10-29 INSTRUMENT_HOST_NAME = "KAGUYA" INSTRUMENT_NAME = "SPECTRAL PROFILER" DATA_SET_ID = "KAGUYA-L-SP-5-SPECTRA-V1.0" START_TIME = "2007-11-02T16:52:39" STOP_TIME = "2009-06-10T18:24:40" TARGET_NAME = "MOON" SPACECRAFT_CLOCK_START_COUNT = "UNK" SPACECRAFT_CLOCK_STOP_COUNT = "UNK" ^HEADER = ("SMCRAT_SPECTRA.CSV",1) ^SPREADSHEET = ("SMCRAT_SPECTRA.CSV",2517 ) OBJECT = HEADER HEADER_TYPE = TEXT BYTES = 2516 DESCRIPTION = "The header lists the column names for the table that follows. Columns 13-166 list the wavelengths at which each spectrum is measured." END_OBJECT = HEADER OBJECT = SPREADSHEET FIELD_DELIMITER = "COMMA" FIELDS = 13 ROW_BYTES = 2312 ROWS = 8184 DESCRIPTION = " This file contains the spectra and analytical products presented in LUCEYETAL2014. The spectra are derived from the SELENE Spectral Profiler and represent 8183 spectra of small immature craters. The data file (smcrat_spectra.csv) has 166 columns and 8184 rows. The first 12 columns are descriptive data and the 13th through 166th column are the photometrically corrected Spectral Profiler spectra of the small craters. At the time of the production of the LUCEYETAL2014 paper, the valid data range was 0.5 and 1.6 microns, though the data contained in the archive include data beyond 1.6 microns. The first row of the file contains the column descriptors. The first 3 columns are the latitude, longitude, and SELENE revolution number from which each spectrum was derived. The fourth column is a flag that indicates a single spectrum for a crater (0) or is one of several sequential spectra of a crater (1). The fifth column is the FeO content determined from the spectrum using the algorithm of LAWRENCEETAL2002. The sixth column is the optical maturity parameter OMAT from LUCEYETAL2000. Columns 7 through 12 are the result of fitting each spectrum with a radiative transfer model described in LUCEYETAL2014. The columns are: 7) Olivine (wt. %) 8) Low calcium pyroxene (wt. %) 9) High calcium pyroxene (wt. %) 10) Plagioclase (wt. %) 11) Submicroscopic iron (1 micron diameter) 12) Submicroscopic iron (< 300 nm diameter) Columns 13-166 are the wavelengths of the spectral channels used in the analysis (13 columns of descriptive data and 153 columns of spectral data values). Invalid spectral data values are assigned the value -99.0000." OBJECT = FIELD NAME = "LATITUDE" FIELD_NUMBER = 1 DATA_TYPE = ASCII_REAL BYTES = 13 UNIT = "DEGREE" DESCRIPTION = "Latitude in degrees as derived from JAXA database." END_OBJECT = FIELD OBJECT = FIELD NAME = "LONGITUDE" FIELD_NUMBER = 2 DATA_TYPE = ASCII_REAL BYTES = 13 UNIT = "DEGREE" DESCRIPTION = "Longitude in degrees as derived from JAXA database." END_OBJECT = FIELD OBJECT = FIELD NAME = "REVOLUTION_NUMBER" FIELD_NUMBER = 3 DATA_TYPE = ASCII_REAL BYTES = 13 DESCRIPTION = "Revolution number (orbit number) of the spectrum." END_OBJECT = FIELD OBJECT = FIELD NAME = "MULTIPLE_SPECTRA_FLAG" FIELD_NUMBER = 4 DATA_TYPE = ASCII_REAL BYTES = 13 DESCRIPTION = "Flag indicating a single spectrum of a crater (0) or one of several sequential spectra of a crater (1)." END_OBJECT = FIELD OBJECT = FIELD NAME = "FeO" FIELD_NUMBER = 5 DATA_TYPE = ASCII_REAL BYTES = 13 INVALID_CONSTANT = -99.0000 DESCRIPTION = "FeO content of the location derived from the spectrum using the algorithm of LAWRENCEETAL2002." END_OBJECT = FIELD OBJECT = FIELD NAME = "OMAT" FIELD_NUMBER = 6 DATA_TYPE = ASCII_REAL BYTES = 13 DESCRIPTION = "Optical maturity parameter OMAT derived from the spectrum using the algorithm of LUCEYETAL2000." END_OBJECT = FIELD OBJECT = FIELD NAME = "OLIVINE_WT%" FIELD_NUMBER = 7 DATA_TYPE = ASCII_REAL BYTES = 13 DESCRIPTION = "Weight percent olivine derived from radiative transfer modeling of the spectrum." END_OBJECT = FIELD OBJECT = FIELD NAME = "ORTHOPYROXENE_WT.%" FIELD_NUMBER = 8 DATA_TYPE = ASCII_REAL BYTES = 13 DESCRIPTION = "Weight percent orthopyroxene derived from radiative transfer modeling of the spectrum." END_OBJECT = FIELD OBJECT = FIELD NAME = "CLINOPYROXENE_WT.%" FIELD_NUMBER = 9 DATA_TYPE = ASCII_REAL BYTES = 13 DESCRIPTION = "Weight percent clinopyroxene derived from radiative transfer modeling of the spectrum." END_OBJECT = FIELD OBJECT = FIELD NAME = "PLAGIOCLASE_WT.%" FIELD_NUMBER = 10 DATA_TYPE = ASCII_REAL BYTES = 13 DESCRIPTION = "Weight percent plagioclase derived from radiative transfer modeling of the spectrum." END_OBJECT = FIELD OBJECT = FIELD NAME = "SUBMICROSCOPIC_IRON_1UM" FIELD_NUMBER = 11 DATA_TYPE = ASCII_REAL BYTES = 13 DESCRIPTION = "Weight fraction 1 micrometer iron. Values are derived from a quantized lookup table with increments of 0.0005 weight fraction." END_OBJECT = FIELD OBJECT = FIELD NAME = "SUBMICROSCOPIC_IRON_LT_300NM" FIELD_NUMBER = 12 DATA_TYPE = ASCII_REAL BYTES = 13 DESCRIPTION = "Abundance of <300 nm iron in mg/g. Values are derived from a quantized lookup table with increments of 1 mg/g." END_OBJECT = FIELD OBJECT = FIELD NAME = "SPECTRUM" FIELD_NUMBER = 13 DATA_TYPE = ASCII_REAL INVALID_CONSTANT = -99.0000 BYTES = 2142 ITEMS = 153 ITEM_BYTES = 13 DESCRIPTION = "Spectral reflectance values." END_OBJECT = FIELD END_OBJECT = SPREADSHEET END