<?xml version="1.0" encoding="utf-8"?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1700.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<Product_Observational xmlns="http://pds.nasa.gov/pds4/pds/v1"
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://pds.nasa.gov/pds4/pds/v1 https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1700.xsd">

  <Identification_Area>
    <logical_identifier>urn:nasa:pds:a17leam_raw_arcsav:data:a17_leam_1975155_l1_arcsav_tab</logical_identifier>
    <version_id>1.0</version_id>
    <title>Apollo 17 Lunar Ejecta And Meteorites Experiment Raw Cleaned ASCII Science Data for
    1975-155</title>
    <information_model_version>1.7.0.0</information_model_version>
    <product_class>Product_Observational</product_class>
  </Identification_Area>
  <Observation_Area>
    <Time_Coordinates>
      <start_date_time>1975-06-03T23:59:59.736Z</start_date_time>
      <stop_date_time>1975-06-04T23:59:58.252Z</stop_date_time>
    </Time_Coordinates>
    <Investigation_Area>
      <name>Apollo 17</name>
      <type>Mission</type>
      <Internal_Reference>
        <lid_reference>urn:nasa:pds:context:investigation:mission.apollo_17</lid_reference>
        <reference_type>data_to_investigation</reference_type>
      </Internal_Reference>
    </Investigation_Area>
    <Observing_System>
      <Observing_System_Component>
        <name>Apollo 17 ALSEP</name>
        <type>Spacecraft</type>
        <Internal_Reference>
          <lid_reference>urn:nasa:pds:context:instrument_host:spacecraft.a17a</lid_reference>
          <reference_type>is_instrument_host</reference_type>
        </Internal_Reference>
      </Observing_System_Component>
      <Observing_System_Component>
        <name>Apollo 17 Lunar Seismic Gravimeter</name>
        <type>Instrument</type>
        <Internal_Reference>
          <lid_reference>urn:nasa:pds:context:instrument:leam.a17a</lid_reference>
          <reference_type>is_instrument</reference_type>
        </Internal_Reference>
      </Observing_System_Component>
    </Observing_System>
    <Target_Identification>
      <name>MOON</name>
      <type>Satellite</type>
      <Internal_Reference>
        <lid_reference>urn:nasa:pds:context:target:satellite.earth.moon</lid_reference>
        <reference_type>data_to_target</reference_type>
      </Internal_Reference>
    </Target_Identification>
    <Target_Identification>
      <name>Dust</name>
      <type>Dust</type>
      <Internal_Reference>
        <lid_reference>urn:nasa:pds:context:target:dust.dust</lid_reference>
        <reference_type>data_to_target</reference_type>
      </Internal_Reference>
    </Target_Identification>
  </Observation_Area>
  <File_Area_Observational>
    <File>
      <file_name>a17_leam_1975155_l1_arcsav.tab</file_name>
      <file_size unit="byte">7497600</file_size>
      <records>28400</records>
    </File>
    <Header>
      <name>Header</name>
      <offset unit="byte">0</offset>
      <object_length unit="byte">264</object_length>
      <parsing_standard_id>7-Bit ASCII Text</parsing_standard_id>
    </Header>
    <Table_Character>
      <name>TimeOffsets</name>
      <offset unit="byte">264</offset>
      <records>1</records>
      <description>This table provides derived sampling-rate-adjusted delay time as an offset in
      milliseconds for computing the time for each data measurement in each RawData Table record.
      The recorded time stamp provided in the first column of each RawData record is the reference
      earth-received time for the sequence of data measurements within that record. To compute the
      time for a specific data measurement, add the milliseconds time offset, found in this
      single-record table TimeOffsets for the data measurement column of interest, to the recorded
      time stamp in the first column of the RawData record containing the data measurement of
      interest.</description>
      <record_delimiter>Carriage-Return Line-Feed</record_delimiter>
      <Record_Character>
        <fields>31</fields>
        <groups>0</groups>
        <record_length unit="byte">264</record_length>
        <Field_Character>
          <name>DJ-1_TimeOffset</name>
          <field_number>1</field_number>
          <field_location unit="byte">25</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-1. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-1 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-2_TimeOffset</name>
          <field_number>2</field_number>
          <field_location unit="byte">32</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-2. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-2 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-3_TimeOffset</name>
          <field_number>3</field_number>
          <field_location unit="byte">39</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-3. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-3 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-4_TimeOffset</name>
          <field_number>4</field_number>
          <field_location unit="byte">46</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-4. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-4 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-5_TimeOffset</name>
          <field_number>5</field_number>
          <field_location unit="byte">53</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-5. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-5 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-6_TimeOffset</name>
          <field_number>6</field_number>
          <field_location unit="byte">60</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-6. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-6 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-7_TimeOffset</name>
          <field_number>7</field_number>
          <field_location unit="byte">67</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-7. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-7 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-8_TimeOffset</name>
          <field_number>8</field_number>
          <field_location unit="byte">74</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-8. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-8 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-9_TimeOffset</name>
          <field_number>9</field_number>
          <field_location unit="byte">81</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-9. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-9 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-10_TimeOffset</name>
          <field_number>10</field_number>
          <field_location unit="byte">89</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-10. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-10 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-11_TimeOffset</name>
          <field_number>11</field_number>
          <field_location unit="byte">97</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-11. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-11 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-12_TimeOffset</name>
          <field_number>12</field_number>
          <field_location unit="byte">105</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-12. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-12 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-13_TimeOffset</name>
          <field_number>13</field_number>
          <field_location unit="byte">113</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-13. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-13 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-14_TimeOffset</name>
          <field_number>14</field_number>
          <field_location unit="byte">121</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-14. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-14 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-15_TimeOffset</name>
          <field_number>15</field_number>
          <field_location unit="byte">129</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-15. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-15 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-16_TimeOffset</name>
          <field_number>16</field_number>
          <field_location unit="byte">137</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-16. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-16 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-17_TimeOffset</name>
          <field_number>17</field_number>
          <field_location unit="byte">145</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-17. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-17 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-18_TimeOffset</name>
          <field_number>18</field_number>
          <field_location unit="byte">153</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-18. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-18 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-19_TimeOffset</name>
          <field_number>19</field_number>
          <field_location unit="byte">161</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-19. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-19 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-20_TimeOffset</name>
          <field_number>20</field_number>
          <field_location unit="byte">169</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-20. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-20 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-21_TimeOffset</name>
          <field_number>21</field_number>
          <field_location unit="byte">177</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-21. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-21 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-22_TimeOffset</name>
          <field_number>22</field_number>
          <field_location unit="byte">185</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-22. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-22 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-23_TimeOffset</name>
          <field_number>23</field_number>
          <field_location unit="byte">193</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-23. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-23 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-24_TimeOffset</name>
          <field_number>24</field_number>
          <field_location unit="byte">201</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-24. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-24 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-25_TimeOffset</name>
          <field_number>25</field_number>
          <field_location unit="byte">209</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-25. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-25 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-26_TimeOffset</name>
          <field_number>26</field_number>
          <field_location unit="byte">217</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-26. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-26 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-27_TimeOffset</name>
          <field_number>27</field_number>
          <field_location unit="byte">225</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-27. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-27 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-28_TimeOffset</name>
          <field_number>28</field_number>
          <field_location unit="byte">233</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-28. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-28 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-29_TimeOffset</name>
          <field_number>29</field_number>
          <field_location unit="byte">241</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-29. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-29 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-30_TimeOffset</name>
          <field_number>30</field_number>
          <field_location unit="byte">249</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-30. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-30 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-31_TimeOffset</name>
          <field_number>31</field_number>
          <field_location unit="byte">257</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DJ-31. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DJ-31 data value in that record.</description>
        </Field_Character>
      </Record_Character>
    </Table_Character>
    <Table_Character>
      <name>RawData</name>
      <offset unit="byte">528</offset>
      <records>28398</records>
      <description>This table contains raw scientific measurements from the Up, East and West LEAM
      sensors extracted from one daily ALSEP ARCSAV tape. Each record begins with the reference
      earth-received time for the set of data in that record followed by 31 raw data numbers
      identified by their LEAM Measurement Number, DJ-N: 11 measurements for the Up dual sensor
      assembly (DJ-1 to DJ-11); 11 measurements for the East dual sensor assembly (DJ-12 to DJ-22);
      7 measurements for the West single sensor assembly (DJ-23 to DJ-27, DJ-30, and DJ-31); and 2
      engineering fields (DJ-28 and DG-29). The earth-received time column and each data measurement
      column are followed by a quality flag. Records are ordered by the earth-received
      time.</description>
      <record_delimiter>Carriage-Return Line-Feed</record_delimiter>
      <Record_Character>
        <fields>64</fields>
        <groups>0</groups>
        <record_length unit="byte">264</record_length>
        <Field_Character>
          <name>EarthReceivedTime</name>
          <field_number>1</field_number>
          <field_location unit="byte">1</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">21</field_length>
          <field_format>%-21s</field_format>
          <description>Day of year and time (Universal Time, formatted as yyyy-dddThh:mm:ss.sss)
          when the first word of the ALSEP frame containing the DJ-1 measurement within this record
          was received at a ground tracking and receiving station on earth. Each data measurement
          has time offset (delta t) from this earth-received time. These timing offsets are
          contained in the single-record, TimeOffsets Table.</description>
        </Field_Character>
        <Field_Character>
          <name>EarthReceivedTime_Flag</name>
          <field_number>2</field_number>
          <field_location unit="byte">23</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this
          EarthReceivedTime value is from ground software clock; has a suspected transmission, data
          synchronization or tape read error in the value; or is clearly outside the expected range
          for this restoration effort. A negative sign (-) indicates this value is the
          earth-received time, and the value does not have a suspected read or transmission error
          or that it is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-1</name>
          <field_number>3</field_number>
          <field_location unit="byte">26</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-1. Front Film ID for Up dual sensor assembly from
          ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-1_Flag</name>
          <field_number>4</field_number>
          <field_location unit="byte">30</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-2</name>
          <field_number>5</field_number>
          <field_location unit="byte">33</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-2. Front Film Pulse Height Analyzer for Up dual sensor
          assembly from ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-2_Flag</name>
          <field_number>6</field_number>
          <field_location unit="byte">37</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-3</name>
          <field_number>7</field_number>
          <field_location unit="byte">40</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-3. Front Film Accumulator for Up dual sensor assembly
          from ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-3_Flag</name>
          <field_number>8</field_number>
          <field_location unit="byte">44</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-4</name>
          <field_number>9</field_number>
          <field_location unit="byte">47</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-4. Rear Film ID for Up dual sensor assembly from ALSEP
          Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-4_Flag</name>
          <field_number>10</field_number>
          <field_location unit="byte">51</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-5</name>
          <field_number>11</field_number>
          <field_location unit="byte">54</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-5. Rear Film Pulse Height Analyzer for Up dual sensor
          assembly from ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-5_Flag</name>
          <field_number>12</field_number>
          <field_location unit="byte">58</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-6</name>
          <field_number>13</field_number>
          <field_location unit="byte">61</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-6. Rear Film Accumulator for Up dual sensor assembly
          from ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-6_Flag</name>
          <field_number>14</field_number>
          <field_location unit="byte">65</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-7</name>
          <field_number>15</field_number>
          <field_location unit="byte">68</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-7. Front Collector ID for Up dual sensor assembly from
          ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-7_Flag</name>
          <field_number>16</field_number>
          <field_location unit="byte">72</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-8</name>
          <field_number>17</field_number>
          <field_location unit="byte">75</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-8. Microphone Pulse Height Analyzer for Up dual
          sensor assembly from ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-8_Flag</name>
          <field_number>18</field_number>
          <field_location unit="byte">79</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-9</name>
          <field_number>19</field_number>
          <field_location unit="byte">82</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-9. Microphone Accumulator for Up dual sensor assembly
          from ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-9_Flag</name>
          <field_number>20</field_number>
          <field_location unit="byte">86</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-10</name>
          <field_number>21</field_number>
          <field_location unit="byte">90</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-10. Rear Collector ID for Up dual sensor assembly from
          ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-10_Flag</name>
          <field_number>22</field_number>
          <field_location unit="byte">94</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-11</name>
          <field_number>23</field_number>
          <field_location unit="byte">98</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-11. Elapsed Time of Flight between front and rear film
          for Up dual sensor assembly from ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-11_Flag</name>
          <field_number>24</field_number>
          <field_location unit="byte">102</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-12</name>
          <field_number>25</field_number>
          <field_location unit="byte">106</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-12. Front Film ID for East dual sensor assembly from
          ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-12_Flag</name>
          <field_number>26</field_number>
          <field_location unit="byte">110</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-13</name>
          <field_number>27</field_number>
          <field_location unit="byte">114</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-13. Front Film Pulse Height Analyzer for East dual
          sensor assembly from ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-13_Flag</name>
          <field_number>28</field_number>
          <field_location unit="byte">118</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-14</name>
          <field_number>29</field_number>
          <field_location unit="byte">122</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-14. Front Film Accumulator for East dual sensor
          assembly from ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-14_Flag</name>
          <field_number>30</field_number>
          <field_location unit="byte">126</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-15</name>
          <field_number>31</field_number>
          <field_location unit="byte">130</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-15. Rear Film ID for East dual sensor assembly from
          ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-15_Flag</name>
          <field_number>32</field_number>
          <field_location unit="byte">134</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-16</name>
          <field_number>33</field_number>
          <field_location unit="byte">138</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-16. Rear Film Pulse Height Analyzer for East dual
          sensor assembly from ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-16_Flag</name>
          <field_number>34</field_number>
          <field_location unit="byte">142</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-17</name>
          <field_number>35</field_number>
          <field_location unit="byte">146</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-17. Rear Film Accumulator for East dual sensor
          assembly from ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-17_Flag</name>
          <field_number>36</field_number>
          <field_location unit="byte">150</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-18</name>
          <field_number>37</field_number>
          <field_location unit="byte">154</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-18. Front Collector ID for East dual sensor assembly
          from ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-18_Flag</name>
          <field_number>38</field_number>
          <field_location unit="byte">158</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-19</name>
          <field_number>39</field_number>
          <field_location unit="byte">162</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-19. Microphone Pulse Height Analyzer for East dual
          sensor assembly from ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-19_Flag</name>
          <field_number>40</field_number>
          <field_location unit="byte">166</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-20</name>
          <field_number>41</field_number>
          <field_location unit="byte">170</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-20. Microphone Accumulator for East dual sensor
          assembly from ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-20_Flag</name>
          <field_number>42</field_number>
          <field_location unit="byte">174</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-21</name>
          <field_number>43</field_number>
          <field_location unit="byte">178</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-21. Rear Collector ID for East dual sensor assembly
          from ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-21_Flag</name>
          <field_number>44</field_number>
          <field_location unit="byte">182</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-22</name>
          <field_number>45</field_number>
          <field_location unit="byte">186</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-22. Elapsed Time of Flight between front and rear film
          for East dual sensor assembly from ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-22_Flag</name>
          <field_number>46</field_number>
          <field_location unit="byte">190</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-23</name>
          <field_number>47</field_number>
          <field_location unit="byte">194</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-23. Film ID for West single sensor assembly from ALSEP
          Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-23_Flag</name>
          <field_number>48</field_number>
          <field_location unit="byte">198</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-24</name>
          <field_number>49</field_number>
          <field_location unit="byte">202</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-24. Collector ID for West single sensor assembly from
          ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-24_Flag</name>
          <field_number>50</field_number>
          <field_location unit="byte">206</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-25</name>
          <field_number>51</field_number>
          <field_location unit="byte">210</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-25. Film Pulse Height Analyzer for West single sensor
          assembly from ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-25_Flag</name>
          <field_number>52</field_number>
          <field_location unit="byte">214</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-26</name>
          <field_number>53</field_number>
          <field_location unit="byte">218</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-26. Film Accumulator for West single sensor assembly
          from ALSEP Word 31.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-26_Flag</name>
          <field_number>54</field_number>
          <field_location unit="byte">222</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-27</name>
          <field_number>55</field_number>
          <field_location unit="byte">226</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-27. Secondary Microfilm Accumulator for West single
          sensor assembly from ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-27_Flag</name>
          <field_number>56</field_number>
          <field_location unit="byte">230</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-28</name>
          <field_number>57</field_number>
          <field_location unit="byte">234</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-28. Analog Data Synchronization ID Bit from ALSEP Word
          39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-28_Flag</name>
          <field_number>58</field_number>
          <field_location unit="byte">238</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-29</name>
          <field_number>59</field_number>
          <field_location unit="byte">242</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-29. Heater Status from ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-29_Flag</name>
          <field_number>60</field_number>
          <field_location unit="byte">246</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-30</name>
          <field_number>61</field_number>
          <field_location unit="byte">250</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-30. West Main Microphone Pulse Height Analyzer from
          ALSEP Word 39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-30_Flag</name>
          <field_number>62</field_number>
          <field_location unit="byte">254</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DJ-31</name>
          <field_number>63</field_number>
          <field_location unit="byte">258</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DJ-31. West Main Microphone Accumulator from ALSEP Word
          39.</description>
          <Special_Constants>
            <missing_constant>-9</missing_constant>
          </Special_Constants>
        </Field_Character>
        <Field_Character>
          <name>DJ-31_Flag</name>
          <field_number>64</field_number>
          <field_location unit="byte">262</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it is
          unknown if there was an error.</description>
        </Field_Character>
      </Record_Character>
    </Table_Character>
  </File_Area_Observational>