OBJECT = COLUMN NAME = MET COLUMN_NUMBER = 1 BYTES = 12 DATA_TYPE = ASCII_INTEGER START_BYTE = 1 DESCRIPTION = "Mission Elapsed Time in seconds." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ORBIT_NUMBER COLUMN_NUMBER = 2 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 15 DESCRIPTION = "Orbit number is a unique identifier for a given orbit of the MESSENGER spacecraft around Mercury. Orbit number is defined as starting at apoherm and is calculated using the MET value and the appropriate SPICE kernels. Orbit numbering does not start until MESSENGER performs the Mercury orbit insertion. Until that time the value for orbit number is 0." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_PLUS5V COLUMN_NUMBER = 3 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 23 DESCRIPTION = "LVPS +5 volt monitor." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_NEG5V COLUMN_NUMBER = 4 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 31 DESCRIPTION = "LVPS -5 volt monitor." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_PLUS12V COLUMN_NUMBER = 5 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 39 DESCRIPTION = "LVPS +12 volt monitor." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_NEG12V COLUMN_NUMBER = 6 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 47 DESCRIPTION = "LVPS -12 volt monitor." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_EXT_C1 COLUMN_NUMBER = 7 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 55 DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_EXT_C2 COLUMN_NUMBER = 8 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 63 DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_EXT_C3 COLUMN_NUMBER = 9 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 71 DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_EXT_C4 COLUMN_NUMBER = 10 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 79 DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_EXT_C5 COLUMN_NUMBER = 11 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 87 DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_PLUS5V_I COLUMN_NUMBER = 12 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 95 DESCRIPTION = "LVPS +5V current." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_NEG5V_I COLUMN_NUMBER = 13 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 103 DESCRIPTION = "LVPS -5V current." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_PLUS12V_I COLUMN_NUMBER = 14 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 111 DESCRIPTION = "LVPS +12V current." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_NEG12V_I COLUMN_NUMBER = 15 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 119 DESCRIPTION = "LVPS -12V current." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_TEMP COLUMN_NUMBER = 16 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 127 DESCRIPTION = "LVPS Temperature." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_PRI_I COLUMN_NUMBER = 17 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 135 DESCRIPTION = "LVPS Primary Current." END_OBJECT = COLUMN OBJECT = COLUMN NAME = OP_HEATER_CURRENT COLUMN_NUMBER = 18 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 143 DESCRIPTION = "Op-heater current." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVPS_TEMP COLUMN_NUMBER = 19 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 151 DESCRIPTION = "HVPS Temperature." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVPS_VOLT COLUMN_NUMBER = 20 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 159 DESCRIPTION = "HVPS Voltage." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVPS_REF_VOLT COLUMN_NUMBER = 21 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 167 DESCRIPTION = "HVPS Reference Voltage." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_TEMP_1 COLUMN_NUMBER = 22 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 175 DESCRIPTION = "ADC0 Channel 0, HPGE Detector Temperature 1." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_TEMP_2 COLUMN_NUMBER = 23 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 183 DESCRIPTION = "ADC0 Channel 1, HPGE Detector Temperature 2." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_DET_LEAK COLUMN_NUMBER = 24 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 191 DESCRIPTION = "ADC0 Channel 2, HPGE Detector Leakage current." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVPS_TEMP_2 COLUMN_NUMBER = 25 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 199 DESCRIPTION = "ADC0 Channel 3, HVPS Temperature." END_OBJECT = COLUMN OBJECT = COLUMN NAME = PREAMP_TEMP COLUMN_NUMBER = 26 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 207 DESCRIPTION = "ADC0 Channel 4, Pre Amp Temperature." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SHAPER_TEMP COLUMN_NUMBER = 27 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 215 DESCRIPTION = "ADC0 Channel 5, Shaper Temperature." END_OBJECT = COLUMN OBJECT = COLUMN NAME = AD_TEMP COLUMN_NUMBER = 28 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 223 DESCRIPTION = "ADC0 Channel 6, AD Temperature." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HV_MONITOR COLUMN_NUMBER = 29 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 231 DESCRIPTION = "ADC0 Channel 7, HV Monitor." END_OBJECT = COLUMN OBJECT = COLUMN NAME = REF_2_5V COLUMN_NUMBER = 30 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 239 DESCRIPTION = "ADC0 Channel 8, 2.5V reference." END_OBJECT = COLUMN OBJECT = COLUMN NAME = REF_2_5V_DIV2 COLUMN_NUMBER = 31 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 247 DESCRIPTION = "ADC0 Channel 9, 2.5V reference divided by 2." END_OBJECT = COLUMN OBJECT = COLUMN NAME = REF_2_5V_DIV3 COLUMN_NUMBER = 32 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 255 DESCRIPTION = "ADC0 Channel A, 2.5V reference divided by 3." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CONTROL_BOARD_TEMP COLUMN_NUMBER = 33 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 263 DESCRIPTION = "ADC0 Channel B, Controller Board temperature." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ANNEAL_PRI_VOLT COLUMN_NUMBER = 34 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 271 DESCRIPTION = "ADC1 Channel 0, Anneal primary voltage." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_PRI_VOLT COLUMN_NUMBER = 35 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 279 DESCRIPTION = "ADC1 Channel 1, Cooler primary voltage." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ANNEAL_SEC_I COLUMN_NUMBER = 36 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 287 DESCRIPTION = "ADC1 Channel 2, Anneal secondary current." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_SEC_I COLUMN_NUMBER = 37 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 295 DESCRIPTION = "ADC1 Channel 3, Cooler secondary current." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_PRI_I COLUMN_NUMBER = 38 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 303 DESCRIPTION = "ADC1 Channel 4, Cooler primary current." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ANNEAL_PRI_I COLUMN_NUMBER = 39 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 311 DESCRIPTION = "ADC1 Channel 5, Anneal primary current." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_POWER_BOARD_TEMP COLUMN_NUMBER = 40 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 319 DESCRIPTION = "ADC1 Channel 6, Cooler power board temperature." END_OBJECT = COLUMN OBJECT = COLUMN NAME = STATOR_TEMP COLUMN_NUMBER = 41 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 327 DESCRIPTION = "ADC1 Channel 7, Stator temperature." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVAC_HEATER COLUMN_NUMBER = 42 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 335 DESCRIPTION = "Heater bit register. Bits that define states of anneal heaters." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVAC_RELAY COLUMN_NUMBER = 43 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 343 DESCRIPTION = "Relay bit register. Bits that define states of anneal heater relay circuits." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVAC_HEATER_POWER_LEVEL COLUMN_NUMBER = 44 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 351 DESCRIPTION = "Heater power level." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ANNEAL_MAX_VALID_TEMP COLUMN_NUMBER = 45 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 359 DESCRIPTION = "Anneal max valid temp reading limit." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ANNEAL_UPPER_TEMP COLUMN_NUMBER = 46 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 367 DESCRIPTION = "Anneal upper temp limit." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ANNEAL_LOWER_TEMP COLUMN_NUMBER = 47 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 375 DESCRIPTION = "Anneal lower temp limit." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ANNEAL_MIN_VALID_TEMP COLUMN_NUMBER = 48 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 383 DESCRIPTION = "Anneal min valid temp reading limit." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVAC_COOLER_PWR COLUMN_NUMBER = 49 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 391 DESCRIPTION = "DAC0 Cooler set point." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_HVPS_CMD COLUMN_NUMBER = 50 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 399 DESCRIPTION = "DAC1: HPGe HVPS high voltage value commanded (not actual value)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_HPGE_HV_ENABLE COLUMN_NUMBER = 51 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 407 DESCRIPTION = "Commanded HPGe HV enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_SHIELD_HV_ENABLE COLUMN_NUMBER = 52 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 410 DESCRIPTION = "Commanded Shield HV enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_HEATER_STATE COLUMN_NUMBER = 53 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 413 DESCRIPTION = "Cooler Op-heater state." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_THERMOSTAT COLUMN_NUMBER = 54 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 416 DESCRIPTION = "Cooler thermostat enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_HV_TEMP_OK COLUMN_NUMBER = 55 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 419 DESCRIPTION = "HPGe temp in range for HV." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_TEMP1_ENABLE COLUMN_NUMBER = 56 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 422 DESCRIPTION = "HPGe Temp1 sensor enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_TEMP2_ENABLE COLUMN_NUMBER = 57 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 425 DESCRIPTION = "HPGe Temp2 sensor enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_PILEUP_REJ_ENABLE COLUMN_NUMBER = 58 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 428 DESCRIPTION = "Pileup rejection enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_SCIENCE_MODE COLUMN_NUMBER = 59 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 431 DESCRIPTION = "Commanded to event classification." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_ENABLE COLUMN_NUMBER = 60 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 434 DESCRIPTION = "Cooler enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_PI_ENABLE COLUMN_NUMBER = 61 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 437 DESCRIPTION = "Cooler PI (Proportional Integral) loop control enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_TEMP_OK COLUMN_NUMBER = 62 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 440 DESCRIPTION = "Cooler temperature in range for operation." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_HTR_COOLER_OVERIDE COLUMN_NUMBER = 63 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 443 DESCRIPTION = "Allow anneal heater and cooler." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_HTR_WATCHDOG COLUMN_NUMBER = 64 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 446 DESCRIPTION = "Anneal heater watchdog enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = PULSER_SPECTRUM_ENABLE COLUMN_NUMBER = 65 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 449 DESCRIPTION = "Include pulser events in spectrum." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_SCIENCE_PURGE COLUMN_NUMBER = 66 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 452 DESCRIPTION = "Purge science at end of accumulation." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_UPDATE_MODE COLUMN_NUMBER = 67 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 455 DESCRIPTION = "Mode for immediate update of periods after command sent to change accumulation period (rather than delayed until end of period)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = IN_SCIENCE_MODE COLUMN_NUMBER = 68 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 458 DESCRIPTION = "In an accumulation/reporting cycle." END_OBJECT = COLUMN OBJECT = COLUMN NAME = PREPARE_SCIENCE_DATA COLUMN_NUMBER = 69 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 461 DESCRIPTION = "Prepare to ship latest accumulation." END_OBJECT = COLUMN OBJECT = COLUMN NAME = WATCHDOG_STARTED COLUMN_NUMBER = 70 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 464 DESCRIPTION = "Main watchdog enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = MINOR_SW_VERSION COLUMN_NUMBER = 71 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 467 DESCRIPTION = "Minor software version." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_TEMP_DELTA_MAX COLUMN_NUMBER = 72 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 472 DESCRIPTION = "Maximum diode sensor temperature difference allowed (before safe mode enabled)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_TEMP_LOW_ON COLUMN_NUMBER = 73 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 480 DESCRIPTION = "Maximum temperature to turn on HPGe HV." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_TEMP_HIGH_OFF COLUMN_NUMBER = 74 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 488 DESCRIPTION = "Temperature to turn off HPGe HV." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_HV_BIAS_THRESH COLUMN_NUMBER = 75 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 496 DESCRIPTION = "HPGe bias current safing threshold." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_HV_BIAS_CHECK COLUMN_NUMBER = 76 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 504 DESCRIPTION = "Min HPGe HV to check bias." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_CRITICAL_BIAS COLUMN_NUMBER = 77 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 512 DESCRIPTION = "HPGe critical bias condition." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_CRIT_BIAS_MAX_HV COLUMN_NUMBER = 78 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 520 DESCRIPTION = "HPGe critical bias max HV." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_LVL1_SAF_RETRIES COLUMN_NUMBER = 79 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 528 DESCRIPTION = "HPGe level 1 safing retries." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_LVL1_WAIT_TIME COLUMN_NUMBER = 80 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 536 DESCRIPTION = "HPGe level 1 wait time (minutes)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SHIELD_HV_RATE_THRESH COLUMN_NUMBER = 81 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 544 DESCRIPTION = "Shield event rate safing threshold." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SHIELD_LVL1_SAF_RETRIES COLUMN_NUMBER = 82 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 552 DESCRIPTION = "Shield level 1 safing retries." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SHIELD_LVL1_WAIT_TIME COLUMN_NUMBER = 83 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 560 DESCRIPTION = "Shield level 1 wait time (minutes)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_OP_HEATER_LOW_LIMIT COLUMN_NUMBER = 84 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 568 DESCRIPTION = "Cooler op heater lower limit." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_OP_HEATER_HIGH_LIMIT COLUMN_NUMBER = 85 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 576 DESCRIPTION = "Cooler op heater upper limit." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_PILEUP_OFFSET COLUMN_NUMBER = 86 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 584 DESCRIPTION = "Offset for pileup rejection window." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_PILEUP_HALF_WIDTH COLUMN_NUMBER = 87 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 592 DESCRIPTION = "Time half-width (before or after pulse zero crossing) for pulse pileup rejection." END_OBJECT = COLUMN OBJECT = COLUMN NAME = EVENT_COIN_OFFSET COLUMN_NUMBER = 88 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 600 DESCRIPTION = "Offset for event coincidence window." END_OBJECT = COLUMN OBJECT = COLUMN NAME = EVENT_COIN_HALF_WIDTH COLUMN_NUMBER = 89 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 608 DESCRIPTION = "Time half-width (before or after pulse zero crossing) for coincidence." END_OBJECT = COLUMN OBJECT = COLUMN NAME = NEUTRON_CH0_MIN_E COLUMN_NUMBER = 90 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 616 DESCRIPTION = "Neutron event Channel 0 minimum energy." END_OBJECT = COLUMN OBJECT = COLUMN NAME = NEUTRON_CH0_MAX_E COLUMN_NUMBER = 91 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 624 DESCRIPTION = "Neutron event Channel 0 maximum energy." END_OBJECT = COLUMN OBJECT = COLUMN NAME = NEUTRON_CH1_MIN_E COLUMN_NUMBER = 92 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 632 DESCRIPTION = "Neutron event Channel 1 minimum energy." END_OBJECT = COLUMN OBJECT = COLUMN NAME = NEUTRON_CH1_MAX_E COLUMN_NUMBER = 93 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 640 DESCRIPTION = "Neutron event Channel 1 maximum energy." END_OBJECT = COLUMN OBJECT = COLUMN NAME = PULSER_CH0_MIN_VALID COLUMN_NUMBER = 94 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 648 DESCRIPTION = "Valid pulser minimum energy." END_OBJECT = COLUMN OBJECT = COLUMN NAME = PULSER_CH0_MAX_VALID COLUMN_NUMBER = 95 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 656 DESCRIPTION = "Valid pulser maximum energy." END_OBJECT = COLUMN OBJECT = COLUMN NAME = PULSER_OFFSET COLUMN_NUMBER = 96 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 664 DESCRIPTION = "Pulse height offset for computing pulser height-variation statistics." END_OBJECT = COLUMN OBJECT = COLUMN NAME = PULSER_SHIFT COLUMN_NUMBER = 97 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 672 DESCRIPTION = "Shift pulser energy for spectrum." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CONFIG_CHANGED COLUMN_NUMBER = 98 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 680 DESCRIPTION = "Configuration changed during accumulation." END_OBJECT = COLUMN OBJECT = COLUMN NAME = DIAG_PACKETS_DROPPED COLUMN_NUMBER = 99 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 685 DESCRIPTION = "Number of diagnostic packets dropped." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_I2C_12V COLUMN_NUMBER = 100 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 690 DESCRIPTION = "LVPS 12V enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_I2C_EXT_PR_1 COLUMN_NUMBER = 101 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 693 DESCRIPTION = "LVPS External Primary 1 enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LVPS_I2C_EXT_PR_2 COLUMN_NUMBER = 102 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 696 DESCRIPTION = "LVPS External Primary 2 enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVPS_I2C_HV1_ENABLE COLUMN_NUMBER = 103 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 699 DESCRIPTION = "HVPS (Shield) HV enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVPS_I2C_HV2_ENABLE COLUMN_NUMBER = 104 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 702 DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVPS_I2C_MUX_ENABLE COLUMN_NUMBER = 105 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 705 DESCRIPTION = "Enables/disables ADC MUX on HVPS board to provide HVPS housekeeping data." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVPS_I2C_REF_ENABLE COLUMN_NUMBER = 106 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 708 DESCRIPTION = "Enables/disables use of reference HV on HVPS board to set/regulate HPGe HV." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HVPS_I2C_HV_CMD COLUMN_NUMBER = 107 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 711 DESCRIPTION = "HVPS I2C (Shield) HV Command." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HW_CH0_1SEC COLUMN_NUMBER = 108 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 719 DESCRIPTION = "Hardware channel 0 1-second event total." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HW_CH1_1SEC COLUMN_NUMBER = 109 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 727 DESCRIPTION = "Hardware channel 1 1-second event total." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HW_DEAD_TIME_1SEC COLUMN_NUMBER = 110 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 735 DESCRIPTION = "Hardware dead time 1-second event total." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_CHRG_RSET_1SEC COLUMN_NUMBER = 111 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 743 DESCRIPTION = "Hardware HPGe charge reset 1-second total." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SHLD_CHRG_RSET_1SEC COLUMN_NUMBER = 112 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 751 DESCRIPTION = "Hardware Shield charge reset 1-second total." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CH0_LATCHES_DETECTED COLUMN_NUMBER = 113 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 759 DESCRIPTION = "Number of Channel 0 latches detected (reset at boot time only)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CH1_LATCHES_DETECTED COLUMN_NUMBER = 114 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 764 DESCRIPTION = "Number of Channel 1 latches detected (reset at boot time only)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_HPGE_MAX_HV COLUMN_NUMBER = 115 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 769 DESCRIPTION = "Commanded HPGe max HV level." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_SHIELD_MAX_HV COLUMN_NUMBER = 116 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 777 DESCRIPTION = "Commanded Shield max HV level." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_HPGE_HV COLUMN_NUMBER = 117 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 785 DESCRIPTION = "Commanded HPGe HV level." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_SHIELD_HV COLUMN_NUMBER = 118 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 793 DESCRIPTION = "Commanded Shield HV level." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CALIB_AVG_DET_TEMP COLUMN_NUMBER = 119 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 801 DESCRIPTION = "Calibrated, averaged detector temperature." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_GOAL_HV_ENABLED COLUMN_NUMBER = 120 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 809 DESCRIPTION = "HPGe goal HV if HV enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_GOAL_TEMP_SAFE COLUMN_NUMBER = 121 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 817 DESCRIPTION = "HPGe goal HV if temperature safe." END_OBJECT = COLUMN OBJECT = COLUMN NAME = RAMP_2_HPGE_HV_B COLUMN_NUMBER = 122 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 825 DESCRIPTION = "Implements ramp to HPGE_HV_B value." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_HV_A_BIAS_SAFE COLUMN_NUMBER = 123 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 833 DESCRIPTION = "HPGE_HV_A HV if bias current safe." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_HV_TEMP_CYCLE COLUMN_NUMBER = 124 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 841 DESCRIPTION = "Transitions to or from safe temperature." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_HV_SAFING_LVL COLUMN_NUMBER = 125 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 849 DESCRIPTION = "Current safing level." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_HV_SAFING_CYC COLUMN_NUMBER = 126 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 854 DESCRIPTION = "Times increased safing levels." END_OBJECT = COLUMN OBJECT = COLUMN NAME = HPGE_HV_UNCHANGED_TICKS COLUMN_NUMBER = 127 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 859 DESCRIPTION = "Seconds at current HPGe HV." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SHLD_GOAL_HV_ENABLED COLUMN_NUMBER = 128 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 867 DESCRIPTION = "Shield goal HV if HV enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SHLD_GOAL_EVENT_SAFE COLUMN_NUMBER = 129 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 875 DESCRIPTION = "Shield goal HV if event rate safe." END_OBJECT = COLUMN OBJECT = COLUMN NAME = RAMP_2_SHLD_HV_B COLUMN_NUMBER = 130 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 883 DESCRIPTION = "Implements ramp to SHIELD_HV_B value." END_OBJECT = COLUMN OBJECT = COLUMN NAME = OUTPUT_HVPS_EVENT_SAFE COLUMN_NUMBER = 131 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 891 DESCRIPTION = "Output to HVPS if event rate safe." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SHLD_HV_STATE COLUMN_NUMBER = 132 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 899 DESCRIPTION = "Not used." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SHLD_HV_SAFING_LVL COLUMN_NUMBER = 133 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 904 DESCRIPTION = "Current safing level." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SHLD_HV_SAFING_CYC COLUMN_NUMBER = 134 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 909 DESCRIPTION = "Number of times safing level was increased." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LAST_OPCODE COLUMN_NUMBER = 135 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 914 DESCRIPTION = "Last command opcode received." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SHLD_HV_UNCHANGED_TICKS COLUMN_NUMBER = 136 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 919 DESCRIPTION = "Seconds at current HPGe HV." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_TEMP_SETPOINT COLUMN_NUMBER = 137 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 927 DESCRIPTION = "Cooler temperature set point." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_POWER COLUMN_NUMBER = 138 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 935 DESCRIPTION = "Cooler power (manual or PI loop control)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_PI_PROP COLUMN_NUMBER = 139 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 943 DESCRIPTION = "Cooler PI (Proportional Integral) loop proportional gain (*256)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_PI_INTEGRAL COLUMN_NUMBER = 140 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 951 DESCRIPTION = "Cooler PI (Proportional Integral) loop integral gain (*256)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_PI_OFFSET COLUMN_NUMBER = 141 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 959 DESCRIPTION = "Cooler PI (Proportional Integral) loop offset for output." END_OBJECT = COLUMN OBJECT = COLUMN NAME = COOLER_PI_MAX_ERR COLUMN_NUMBER = 142 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 967 DESCRIPTION = "PI loop max error to enable integration." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ACCUM_TIME_LEFT COLUMN_NUMBER = 143 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 975 DESCRIPTION = "Time left in current accumulation." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_REPORT_PERIOD COLUMN_NUMBER = 144 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 983 DESCRIPTION = "Commanded reporting period." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_ACCUM_TIME COLUMN_NUMBER = 145 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 991 DESCRIPTION = "Commanded accumulation time." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_SHIP_MODE COLUMN_NUMBER = 146 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 999 DESCRIPTION = "Commanded science ship mode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = A2D_SHIP_MODE COLUMN_NUMBER = 147 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 1007 DESCRIPTION = "Microphonics shipmode (compressed)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SCIENCE_PRIORITY COLUMN_NUMBER = 148 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 1015 DESCRIPTION = "Base value for science ApIDs." END_OBJECT = COLUMN OBJECT = COLUMN NAME = STATUS_INTERVAL COLUMN_NUMBER = 149 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 1023 DESCRIPTION = "Status interval (seconds). Defines interval at which status is reported. Not an accumulation interval. All status fields are stationary values." END_OBJECT = COLUMN OBJECT = COLUMN NAME = MACRO_FREE_BLOCKS COLUMN_NUMBER = 150 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 1031 DESCRIPTION = "Free blocks for macros." END_OBJECT = COLUMN OBJECT = COLUMN NAME = TLM_VOLUME COLUMN_NUMBER = 151 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 1039 DESCRIPTION = "Telemetry volume (kB)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = WATCH_ADDR COLUMN_NUMBER = 152 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 1047 DESCRIPTION = "Debug watch address." END_OBJECT = COLUMN OBJECT = COLUMN NAME = WATCH_MEM COLUMN_NUMBER = 153 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 1055 DESCRIPTION = "Debug watch page." END_OBJECT = COLUMN OBJECT = COLUMN NAME = WATCH_BYTE1 COLUMN_NUMBER = 154 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 1063 DESCRIPTION = "Debug watch byte 1." END_OBJECT = COLUMN OBJECT = COLUMN NAME = WATCH_BYTE2 COLUMN_NUMBER = 155 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 1068 DESCRIPTION = "Debug watch byte 2." END_OBJECT = COLUMN OBJECT = COLUMN NAME = SW_VERSION COLUMN_NUMBER = 156 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 1073 DESCRIPTION = "Major software version." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ALARM_ID COLUMN_NUMBER = 157 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 1078 DESCRIPTION = "Last alarm ID." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ALARM_COUNT COLUMN_NUMBER = 158 BYTES = 6 DATA_TYPE = ASCII_INTEGER START_BYTE = 1083 DESCRIPTION = "Total alarm count (can be reset by command)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = ALARM_TYPE COLUMN_NUMBER = 159 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 1091 DESCRIPTION = "Last alarm type." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_EXECUTED COLUMN_NUMBER = 160 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 1094 DESCRIPTION = "Number of commands executed (can be reset by command)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CMD_REJECTED COLUMN_NUMBER = 161 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 1099 DESCRIPTION = "Number of commands rejected (can be reset by command)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = MACRO_CMD_EXEC COLUMN_NUMBER = 162 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 1104 DESCRIPTION = "Macro commands executed (can be reset by command)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = MACRO_CMD_REJECT COLUMN_NUMBER = 163 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 1109 DESCRIPTION = "Macro commands rejected (can be reset by command)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = MACRO_ID COLUMN_NUMBER = 164 BYTES = 3 DATA_TYPE = ASCII_INTEGER START_BYTE = 1114 DESCRIPTION = "Last macro ID." END_OBJECT = COLUMN OBJECT = COLUMN NAME = MACRO_LEARN COLUMN_NUMBER = 165 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 1119 DESCRIPTION = "Macro learning mode." END_OBJECT = COLUMN OBJECT = COLUMN NAME = MEM_WRITE_ENABLE COLUMN_NUMBER = 166 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 1122 DESCRIPTION = "Memory writing enabled." END_OBJECT = COLUMN OBJECT = COLUMN NAME = MON_RESPONSE COLUMN_NUMBER = 167 BYTES = 1 DATA_TYPE = ASCII_INTEGER START_BYTE = 1125 DESCRIPTION = "Monitor response." END_OBJECT = COLUMN