<?xml version="1.0" encoding="utf-8"?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1700.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<Product_Observational xmlns="http://pds.nasa.gov/pds4/pds/v1" 
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://pds.nasa.gov/pds4/pds/v1 https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1700.xsd">

  <Identification_Area>
    <logical_identifier>urn:nasa:pds:a12sws_raw_arcsav:data:a12_sws_1975106_l1_arcsav_w_tab</logical_identifier>
    <version_id>1.0</version_id>
    <title>Apollo 12 Solar Wind Spectrometer Raw Cleaned ASCII Calibration and Engineering Data for
    1975-106</title>
    <information_model_version>1.7.0.0</information_model_version>
    <product_class>Product_Observational</product_class>
  </Identification_Area>
  <Observation_Area>
    <Time_Coordinates>
      <start_date_time>1975-04-15T23:58:47.397Z</start_date_time>
      <stop_date_time>1975-04-16T23:56:11.371Z</stop_date_time>
    </Time_Coordinates>
    <Investigation_Area>
      <name>Apollo 12</name>
      <type>Mission</type>
      <Internal_Reference>
        <lid_reference>urn:nasa:pds:context:investigation:mission.apollo_12</lid_reference>
        <reference_type>data_to_investigation</reference_type>
      </Internal_Reference>
    </Investigation_Area>
    <Observing_System>
      <Observing_System_Component>
        <name>Apollo 12 ALSEP</name>
        <type>Spacecraft</type>
        <Internal_Reference>
          <lid_reference>urn:nasa:pds:context:instrument_host:spacecraft.a12a</lid_reference>
          <reference_type>is_instrument_host</reference_type>
        </Internal_Reference>
      </Observing_System_Component>
      <Observing_System_Component>
        <name>Apollo 12 Solar Wind Spectrometer</name>
        <type>Instrument</type>
        <Internal_Reference>
          <lid_reference>urn:nasa:pds:context:instrument:sws.a12a</lid_reference>
          <reference_type>is_instrument</reference_type>
        </Internal_Reference>
      </Observing_System_Component>
    </Observing_System>
    <Target_Identification>
      <name>MOON</name>
      <type>Satellite</type>
      <Internal_Reference>
        <lid_reference>urn:nasa:pds:context:target:satellite.earth.moon</lid_reference>
        <reference_type>data_to_target</reference_type>
      </Internal_Reference>
    </Target_Identification>
  </Observation_Area>
  <File_Area_Observational>
    <File>
      <file_name>a12_sws_1975106_l1_arcsav_w.tab</file_name>
      <file_size unit="byte">526322</file_size>
      <records>194</records>
    </File>
    <Header>
      <name>Header</name>
      <offset unit="byte">0</offset>
      <object_length unit="byte">2713</object_length>
      <parsing_standard_id>7-Bit ASCII Text</parsing_standard_id>
    </Header>
    <Table_Character>
      <name>TimeOffsets</name>
      <offset unit="byte">2713</offset>
      <records>1</records>
      <description>This table provides derived sampling-rate-adjusted delay time as an offset in
      milliseconds for computing the time for each data measurement in each RawData Table record.
      The recorded time stamp provided in the first column of each RawData record is the
      earth-received time for the sequence of data measurements within that record. To compute the
      time for a specific data measurement, add the milliseconds time offset, found in this
      single-record table TimeOffsets for the data measurement column of interest, to the recorded
      time stamp in the first column of the RawData record containing the data measurement of
      interest. These sampling-rate-adjusted delay times or offsets were calculated using the mean
      ALSEP frame duration for this day of year.</description>
      <record_delimiter>Carriage-Return Line-Feed</record_delimiter>
      <Record_Character>
        <fields>0</fields>
        <groups>49</groups>
        <record_length unit="byte">2713</record_length>
        <Group_Field_Character>
          <name>DW-3_TimeOffsetGroup</name>
          <repetitions>16</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">30</group_location>
          <group_length unit="byte">144</group_length>
          <Field_Character>
            <name>DW-3_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-3. Add this value to the time stamp
            in the first column of a RawData Table record to derive the time for the corresponding
            DW-3 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-4_TimeOffsetGroup</name>
          <repetitions>8</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">174</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-4_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-4. Add this value to the time stamp
            in the first column of a RawData Table record to derive the time for the corresponding
            DW-4 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-5_TimeOffsetGroup</name>
          <repetitions>16</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">246</group_location>
          <group_length unit="byte">144</group_length>
          <Field_Character>
            <name>DW-5_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-5. Add this value to the time stamp
            in the first column of a RawData Table record to derive the time for the corresponding
            DW-5 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-6_TimeOffsetGroup</name>
          <repetitions>8</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">390</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-6_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-6. Add this value to the time stamp
            in the first column of a RawData Table record to derive the time for the corresponding
            DW-6 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-7_TimeOffsetGroup</name>
          <repetitions>16</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">462</group_location>
          <group_length unit="byte">144</group_length>
          <Field_Character>
            <name>DW-7_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-7. Add this value to the time stamp
            in the first column of a RawData Table record to derive the time for the corresponding
            DW-7 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-11_TimeOffsetGroup</name>
          <repetitions>8</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">606</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-11_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-11. Add this value to the time stamp
            in the first column of a RawData Table record to derive the time for the corresponding
            DW-11 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-12_TimeOffsetGroup</name>
          <repetitions>8</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">678</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-12_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-12. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-12 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-13_TimeOffsetGroup</name>
          <repetitions>8</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">750</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-13_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-13. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-13 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-14_TimeOffsetGroup</name>
          <repetitions>8</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">822</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-14_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-14. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-14 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-15_TimeOffsetGroup</name>
          <repetitions>8</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">894</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-15_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-15. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-15 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-16_TimeOffsetGroup</name>
          <repetitions>8</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">966</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-16_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-16. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-16 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-17_TimeOffsetGroup</name>
          <repetitions>8</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1038</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-17_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-17. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-17 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-18_TimeOffsetGroup</name>
          <repetitions>8</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1110</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-18_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-18. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-18 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-19_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1182</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-19_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-19. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-19 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-20_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1218</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-20_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-20. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-20 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-21_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1254</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-21_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-21. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-21 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-22_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1290</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-22_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-22. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-22 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-23_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1326</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-23_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-23. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-23 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-24_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1362</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-24_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-24. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-24 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-25_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1398</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-25_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-25. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-25 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-26_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1434</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-26_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-26. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-26 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-27_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1470</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-27_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-27. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-27 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-28_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1506</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-28_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-28. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-28 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-29_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1542</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-29_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-29. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-29 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-30_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1578</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-30_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-30. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-30 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-31_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1614</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-31_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-31. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-31 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-32_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1650</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-32_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-32. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-32 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-33_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1686</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-33_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-33. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-33 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-34_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1722</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-34_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-34. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-34 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-35_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1758</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-35_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-35. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-35 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-36_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1794</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-36_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-36. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-36 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-37_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1830</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-37_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-37. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-37 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-38_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1866</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-38_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-38. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-38 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-39_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1902</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-39_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-39. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-39 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-40_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1938</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-40_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-40. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-40 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-41_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">1974</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-41_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-41. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-41 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-42_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2010</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-42_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-42. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-42 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-43_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2046</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-43_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-43. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-43 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-44_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2082</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-44_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-44. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-44 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-45_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2118</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-45_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-45. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-45 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-46_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2154</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-46_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-46. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-46 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-47_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2190</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-47_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-47. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-47 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-48_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2226</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-48_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-48. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-48 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-49_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2262</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-49_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-49. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-49 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-50_TimeOffsetGroup</name>
          <repetitions>4</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2298</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-50_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DW-50. Add this value to the time
            stamp in the first column of a RawData Table record to derive the time for the
            corresponding DW-50 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-51_to_DW-64_DC_HV_Cal_Lev_1-14_Prot_TimeOffsetGroup</name>
          <repetitions>14</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2334</group_location>
          <group_length unit="byte">126</group_length>
          <Field_Character>
            <name>DW-51_to_DW-64_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Numbers DW-50 through DW-64. Add this value
            to the time stamp in the first column of a RawData Table record to derive the time for
            the corresponding DW-50 through DW-64 data values in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-65_to_DW-71_DC_HV_Cal_Lev_1-7_Elec_TimeOffsetGroup</name>
          <repetitions>7</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2460</group_location>
          <group_length unit="byte">63</group_length>
          <Field_Character>
            <name>DW-65_to_DW-71_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Numbers DW-65 through DW-71. Add this value
            to the time stamp in the first column of a RawData Table record to derive the time for
            the corresponding DW-65 through DW-71 data values in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-72_to_DW-85_AC_HV_Cal_Lev_1-14_Prot_TimeOffsetGroup</name>
          <repetitions>14</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2523</group_location>
          <group_length unit="byte">126</group_length>
          <Field_Character>
            <name>DW-72_to_DW-85_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Numbers DW-72 through DW-85. Add this value
            to the time stamp in the first column of a RawData Table record to derive the time for
            the corresponding DW-72 through DW-85 data values in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-86_to_DW-92_AC_HV_Cal_Lev_1-7_Elec_TimeOffsetGroup</name>
          <repetitions>7</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">2649</group_location>
          <group_length unit="byte">63</group_length>
          <Field_Character>
            <name>DW-86_to_DW-92_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">2</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">6</field_length>
            <field_format>%6d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Numbers DW-86 through DW-92. Add this value
            to the time stamp in the first column of a RawData Table record to derive the time for
            the corresponding DW-86 through DW-92 data values in that record.</description>
          </Field_Character>
        </Group_Field_Character>
      </Record_Character>
    </Table_Character>
    <Table_Character>
      <name>RawData</name>
      <offset unit="byte">5426</offset>
      <records>192</records>
      <description>This table contains the raw SWS calibration, engineering, and voltage level data
      measurements (DW-n) extracted from one daily ALSEP ARCSAV tape. Each record contains all 92 DW
      measurements for the given SWS cycle. Each record begins with the earth-received reference
      time for the set of data in that record, followed by the cycle number, then measurements DW-1
      to DW-92. The earth-received time column and each data measurement column are followed by a
      quality flag. Records are time-ordered by the earth-received time. </description>
      <record_delimiter>Carriage-Return Line-Feed</record_delimiter>
      <Record_Character>
        <fields>3</fields>
        <groups>49</groups>
        <record_length unit="byte">2713</record_length>
        <Field_Character>
          <name>EarthReceivedTime</name>
          <field_number>1</field_number>
          <field_location unit="byte">1</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">21</field_length>
          <field_format>%-21s</field_format>
          <description>Day of year and time (Universal Time, formatted as yyyy-dddThh:mm:ss.sss)
          when the first word of the ALSEP frame containing the sequence of data measurements within
          this record was received at a ground tracking and receiving station on earth. Each data
          measurement has time offset (delta t) from this earth received time. These timing offsets
          are contained in the single-record, TimeOffsets Table.</description>
        </Field_Character>
        <Field_Character>
          <name>EarthReceivedTime_Flag</name>
          <field_number>2</field_number>
          <field_location unit="byte">23</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format> 
          <description>This field is set one of two values: An asterisk (*) indicates this
          EarthReceivedTime value is from ground software clock; has a suspected transmission, data
          synchronization or tape read error in the value; or is clearly outside the expected range
          for this restoration effort. A negative sign (-) indicates this value is the
          earth-received time, and the value does not have a suspected read or transmission error or
          that it is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>Cycle_Number</name>
          <field_number>3</field_number>
          <field_location unit="byte">26</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>SWS data cycle number.</description>
        </Field_Character>
        <Group_Field_Character>
          <name>DW-3_Group</name>
          <repetitions>16</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">30</group_location>
          <group_length unit="byte">144</group_length>
          <Field_Character>
            <name>DW-3</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-3. Analog-to-digital (A/D) converter calibration
            measurements from SWS data words 112 and 117, respectively, for even SWS sequences.
            Values range from 0 to +255.</description>
          </Field_Character>
          <Field_Character>
            <name>DW-3_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-4_Group</name>
          <repetitions>8</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">174</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-4</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-4. Analog-to-digital (A/D) converter calibration
            data. Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-4_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-5_Group</name>
          <repetitions>16</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">246</group_location>
          <group_length unit="byte">144</group_length>
          <Field_Character>
            <name>DW-5</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-5. Analog-to-digital (A/D) converter calibration
            measurements from SWS data words 114 and 118, respectively, for even SWS sequences.
            Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-5_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-6_Group</name>
          <repetitions>8</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">390</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-6</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-6. Analog-to-digital (A/D) converter calibration
            data. Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-6_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-7_Group</name>
          <repetitions>16</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">462</group_location>
          <group_length unit="byte">144</group_length>
          <Field_Character>
            <name>DW-7</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-7. Analog-to-digital (A/D) converter calibration
            measurements from SWS data words 116 and 119, respectively, for even SWS sequences.
            Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-7_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-11_Group</name>
          <repetitions>8</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">606</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-11</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-11. Engineering data: Temperature sensor mod 100.
            Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-11_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-12_Group</name>
          <repetitions>8</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">678</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-12</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-12. Engineering data: Temperature sensor mod 200.
            Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-12_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-13_Group</name>
          <repetitions>8</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">750</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-13</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-13. Engineering data: Temperature sensor mod 300.
            Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-13_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-14_Group</name>
          <repetitions>8</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">822</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-14</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-14. Engineering data: Temperature sensor cup
            assembly. Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-14_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-15_Group</name>
          <repetitions>8</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">894</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-15</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-15. Engineering data: Sun angle sensor. Values range
            from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-15_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-16_Group</name>
          <repetitions>8</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">966</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-16</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-16. Engineering data: Programmer voltage. Values
            range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-16_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-17_Group</name>
          <repetitions>8</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1038</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-17</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-17. Engineering data: Step gen voltage. Values range
            from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-17_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-18_Group</name>
          <repetitions>8</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1110</group_location>
          <group_length unit="byte">72</group_length>
          <Field_Character>
            <name>DW-18</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-18. Engineering data: Modulation monitor. Values
            range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-18_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-19_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1182</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-19</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-19. Current calibration measurement from SWS data
            word number 120 in SWS sequences 0, 4, 8, and 12, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-19_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-20_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1218</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-20</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-20. Current calibration measurement from SWS data
            word number 121 in SWS sequences 0, 4, 8, and 12, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-20_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-21_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1254</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-21</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-21. Current calibration measurement from SWS data
            word number 122 in SWS sequences 0, 4, 8, and 12, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-21_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-22_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1290</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-22</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-22. Current calibration measurement from SWS data
            word number 123 in SWS sequences 0, 4, 8, and 12, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-22_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-23_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1326</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-23</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-23. Current calibration measurement from SWS data
            word number 124 in SWS sequences 0, 4, 8, and 12, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-22_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-24_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1362</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-24</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-24. Current calibration measurement from SWS data
            word number 125 in SWS sequences 0, 4, 8, and 12, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-22_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-25_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1398</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-25</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-25. Current calibration measurement from SWS data
            word number 126 in SWS sequences 0, 4, 8, and 12, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-25_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-26_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1434</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-26</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-26. Current calibration measurement from SWS data
            word number 127 in SWS sequences 0, 4, 8, and 12, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-26_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-27_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1470</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-27</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-27. Current calibration measurement from SWS data
            word number 120 in SWS sequences 1, 5, 9, and 13, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-27_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-28_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1506</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-28</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-28. Current calibration measurement from SWS data
            word number 121 in SWS sequences 1, 5, 9, and 13, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-28_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-29_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1542</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-29</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-29. Current calibration measurement from SWS data
            word number 122 in SWS sequences 1, 5, 9, and 13, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-29_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-30_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1578</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-30</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-30. Current calibration measurement from SWS data
            word number 123 in SWS sequences 1, 5, 9, and 13, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-30_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-31_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1614</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-31</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-31. Current calibration measurement from SWS data
            word number 124 in SWS sequences 1, 5, 9, and 13, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-30_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-32_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1650</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-32</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-32. Current calibration measurement from SWS data
            word number 125 in SWS sequences 1, 5, 9, and 13, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-30_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-33_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1686</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-33</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-33. Current calibration measurement from SWS data
            word number 126 in SWS sequences 1, 5, 9, and 13, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-33_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-34_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1722</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-34</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-34. Current calibration measurement from SWS data
            word number 127 in SWS sequences 1, 5, 9, and 13, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-34_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-35_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1758</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-35</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-35. Current calibration measurement from SWS data
            word number 120 in SWS sequences 2, 6, 10, and 14, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-35_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-36_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1794</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-36</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-36. Current calibration measurement from SWS data
            word number 121 in SWS sequences 2, 6, 10, and 14, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-36_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-37_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1830</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-37</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-37. Current calibration measurement from SWS data
            word number 122 in SWS sequences 2, 6, 10, and 14, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-37_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-38_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1866</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-38</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-38. Current calibration measurement from SWS data
            word number 123 in SWS sequences 2, 6, 10, and 14, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-38_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-39_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1902</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-39</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-39. Current calibration measurement from SWS data
            word number 124 in SWS sequences 2, 6, 10, and 14, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-38_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-40_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1938</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-40</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-40. Current calibration measurement from SWS data
            word number 125 in SWS sequences 2, 6, 10, and 14, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-38_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-41_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">1974</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-41</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-41. Current calibration measurement from SWS data
            word number 126 in SWS sequences 2, 6, 10, and 14, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-41_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-42_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2010</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-42</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-42. Current calibration measurement from SWS data
            word number 127 in SWS sequences 2, 6, 10, and 14, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-42_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-43_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2046</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-43</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-43. Current calibration measurement from SWS data
            word number 120 in SWS sequences 3, 7, 11, and 15, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-43_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-44_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2082</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-44</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-44. Current calibration measurement from SWS data
            word number 121 in SWS sequences 3, 7, 11, and 15, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-44_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-45_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2118</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-45</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-45. Current calibration measurement from SWS data
            word number 122 in SWS sequences 3, 7, 11, and 15, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-45_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-46_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2154</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-46</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-46. Current calibration measurement from SWS data
            word number 123 in SWS sequences 3, 7, 11, and 15, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-46_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-47_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2190</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-47</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-47. Current calibration measurement from SWS data
            word number 124 in SWS sequences 3, 7, 11, and 15, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-46_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-48_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2226</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-48</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-48. Current calibration measurement from SWS data
            word number 125 in SWS sequences 3, 7, 11, and 15, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-46_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-49_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2262</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-49</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-49. Current calibration measurement from SWS data
            word number 126 in SWS sequences 3, 7, 11, and 15, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-49_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-50_Group</name>
          <repetitions>4</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2298</group_location>
          <group_length unit="byte">36</group_length>
          <Field_Character>
            <name>DW-50</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DW-50. Current calibration measurement from SWS data
            word number 127 in SWS sequences 3, 7, 11, and 15, respectively. Values range from 0 
            to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-50_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-51_to_DW-64_DC_HV_Cal_Lev_1-14_Prot_Group</name>
          <repetitions>14</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2334</group_location>
          <group_length unit="byte">126</group_length>
          <Field_Character>
            <name>DW-51_to_DW-64</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Numbers DW-50 through DW-64. There is one DC HV calibration
            measurement for each instrument voltage level from 1 through 14, respectively, for
            proton flux. Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-51_to_DW-64_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-65_to_DW-71_DC_HV_Cal_Lev_1-7_Elec_Group</name>
          <repetitions>7</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2460</group_location>
          <group_length unit="byte">63</group_length>
          <Field_Character>
            <name>DW-65_to_DW-71</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Numbers DW-65 through DW-71. There is one DC HV calibration
            measurement for each instrument voltage level from 1 through 7, respectively, for
            electron flux. Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-65_to_DW-71_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-72_to_DW-85_AC_HV_Cal_Lev_1-14_Prot_Group</name>
          <repetitions>14</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2523</group_location>
          <group_length unit="byte">126</group_length>
          <Field_Character>
            <name>DW-72_to_DW-85</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Numbers DW-72 through DW-85. There is one AC HV calibration
            measurement for each instrument voltage level from 1 through 14, respectively, for
            proton flux. Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-72_to_DW-85_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Group_Field_Character>
          <name>DW-86_to_DW-92_AC_HV_Cal_Lev_1-7_Elec_Group</name>
          <repetitions>7</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">2649</group_location>
          <group_length unit="byte">63</group_length>
          <Field_Character>
            <name>DW-86_to_DW-92</name>
            <field_number>1</field_number>
            <field_location unit="byte">5</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">3</field_length>
            <field_format>%3d</field_format>
            <unit>DN</unit>
            <description>Measurement Numbers DW-86 through DW-92. There is one AC HV calibration
            measurement for each instrument voltage level from 1 through 7, respectively, for
            electron flux. Values range from 0 to +255.</description>
            <Special_Constants>
              <missing_constant>-9</missing_constant>
            </Special_Constants>
          </Field_Character>
          <Field_Character>
            <name>DW-86_to_DW-92_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">9</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
      </Record_Character>
    </Table_Character>
  </File_Area_Observational>
</Product_Observational>