<?xml version="1.0" encoding="utf-8"?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1700.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<Product_Observational xmlns="http://pds.nasa.gov/pds4/pds/v1" 
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://pds.nasa.gov/pds4/pds/v1 https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1700.xsd">

  <Identification_Area>
    <logical_identifier>urn:nasa:pds:a17lsg_raw_arcsav:data:a17_lsg_1975155_l1_arcsav_tab</logical_identifier>
    <version_id>1.0</version_id>
    <title>Apollo 17 Lunar Seismic Gravimeter Raw Cleaned ASCII Science Data for 1975-155</title>
    <information_model_version>1.7.0.0</information_model_version>
    <product_class>Product_Observational</product_class>
  </Identification_Area>
  <Observation_Area>
    <Time_Coordinates>
      <start_date_time>1975-06-03T23:59:59.736Z</start_date_time>
      <stop_date_time>1975-06-04T23:59:59.459Z</stop_date_time>
    </Time_Coordinates>
    <Investigation_Area>
      <name>Apollo 17</name>
      <type>Mission</type>
      <Internal_Reference>
        <lid_reference>urn:nasa:pds:context:investigation:mission.apollo_17</lid_reference>
        <reference_type>data_to_investigation</reference_type>
      </Internal_Reference>
    </Investigation_Area>
    <Observing_System>
      <Observing_System_Component>
        <name>Apollo 17 ALSEP</name>
        <type>Spacecraft</type>
        <Internal_Reference>
          <lid_reference>urn:nasa:pds:context:instrument_host:spacecraft.a17a</lid_reference>
          <reference_type>is_instrument_host</reference_type>
        </Internal_Reference>
      </Observing_System_Component>
      <Observing_System_Component>
        <name>Apollo 17 Lunar Seismic Gravimeter</name>
        <type>Instrument</type>
        <Internal_Reference>
          <lid_reference>urn:nasa:pds:context:instrument:lsg.a17a</lid_reference>
          <reference_type>is_instrument</reference_type>
        </Internal_Reference>
      </Observing_System_Component>
    </Observing_System>
    <Target_Identification>
      <name>MOON</name>
      <type>Satellite</type>
      <Internal_Reference>
        <lid_reference>urn:nasa:pds:context:target:satellite.earth.moon</lid_reference>
        <reference_type>data_to_target</reference_type>
      </Internal_Reference>
    </Target_Identification>
  </Observation_Area>
  <File_Area_Observational>
    <File>
      <file_name>a17_lsg_1975155_l1_arcsav.tab</file_name>
      <file_size unit="byte">49112278</file_size>
      <records>141943</records>
    </File>
    <Header>
      <name>Header</name>
      <offset unit="byte">0</offset>
      <object_length unit="byte">346</object_length>
      <parsing_standard_id>7-Bit ASCII Text</parsing_standard_id>
    </Header>
    <Table_Character>
      <name>TimeOffsets</name>
      <offset unit="byte">346</offset>
      <records>1</records> 
      <description>This table provides derived sampling-rate-adjusted delay time as an offset in
      milliseconds for computing the time for each data measurement in each RawData Table record.
      The recorded time stamp provided in the first column of each RawData record is the reference
      earth-received time for the sequence of data measurements within that record. To compute the
      time for a specific data measurement, add the milliseconds time offset, found in this
      single-record table TimeOffsets for the data measurement column of interest, to the recorded
      time stamp in the first column of the RawData record containing the data measurement of
      interest.</description>
      <record_delimiter>Carriage-Return Line-Feed</record_delimiter>
      <Record_Character>
        <fields>12</fields>
        <groups>1</groups>
        <record_length unit="byte">346</record_length>
        <Group_Field_Character>
          <name>DG-1_TimeOffsetGroup</name>
          <repetitions>31</repetitions>
          <fields>1</fields>
          <groups>0</groups>
          <group_location unit="byte">34</group_location>
          <group_length unit="byte">217</group_length>
          <Field_Character>
            <name>DG-1_TimeOffset</name>
            <field_number>1</field_number>
            <field_location unit="byte">1</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">4</field_length>
            <field_format>%4d</field_format>
            <unit>ms</unit>
            <description>Timing offset for Measurement Number DG-1. Add this value to the time stamp
            in the first column of a RawData Table record to derive the time for the corresponding
            DG-1 data value in that record.</description>
          </Field_Character>
        </Group_Field_Character>
        <Field_Character>
          <name>DG-2_TimeOffset</name>
          <field_number>1</field_number>
          <field_location unit="byte">252</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-2. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-2 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-3_TimeOffset</name>
          <field_number>2</field_number>
          <field_location unit="byte">258</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-3. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-3 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-4_TimeOffset</name>
          <field_number>3</field_number>
          <field_location unit="byte">265</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-4. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-4 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-11_TimeOffset</name>
          <field_number>4</field_number>
          <field_location unit="byte">274</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-11. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-11 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-12_TimeOffset</name>
          <field_number>5</field_number>
          <field_location unit="byte">282</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-12. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-12 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-13_TimeOffset</name>
          <field_number>6</field_number>
          <field_location unit="byte">290</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-13. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-13 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-14_TimeOffset</name>
          <field_number>7</field_number>
          <field_location unit="byte">298</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-14. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-14 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-15_TimeOffset</name>
          <field_number>8</field_number>
          <field_location unit="byte">306</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-15. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-15 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-16_TimeOffset</name>
          <field_number>9</field_number>
          <field_location unit="byte">314</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-16. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-16 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-17_TimeOffset</name>
          <field_number>10</field_number>
          <field_location unit="byte">322</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-17. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-17 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-18_TimeOffset</name>
          <field_number>11</field_number>
          <field_location unit="byte">330</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-18. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-18 data value in that record.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-19_TimeOffset</name>
          <field_number>12</field_number>
          <field_location unit="byte">339</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>ms</unit>
          <description>Timing offset for Measurement Number DG-19. Add this value to the time stamp
          in the first column of a RawData Table record to derive the time for the corresponding
          DG-19 data value in that record.</description>
        </Field_Character>
      </Record_Character>
    </Table_Character>
    <Table_Character>
      <name>RawData</name>
      <offset unit="byte">692</offset>
      <records>141941</records>
      <description>This table contains raw scientific measurements from LSG sensors (seismic, tide,
      free mode, and temperature) and experiment operational and command status extracted from one
      daily ALSEP ARCSAV tape. Each record begins with the reference earth-received time for the set
      of data in that record followed by 34 raw scientific measurements identified by their LSG
      Measurement Number, DG-N: 31 seismic (DG-1); 1 tidal (DG-2); 1 free mode (DG-3); and 1
      temperature (DG-4); and 9 experiment status and calibration fields (DG-11 through DG-19 from
      two ALSEP Words). The earth-received time column and each data measurement column are followed
      by a quality flag. Records are ordered by the earth-received time.</description>
      <record_delimiter>Carriage-Return Line-Feed</record_delimiter>
      <Record_Character>
        <fields>28</fields>
        <groups>1</groups>
        <record_length unit="byte">346</record_length>
        <Field_Character>
          <name>EarthReceivedTime</name>
          <field_number>1</field_number>
          <field_location unit="byte">1</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">21</field_length>
          <field_format>%-21s</field_format>
          <description>Day of year and time (Universal Time, formatted as yyyy-dddThh:mm:ss.sss)
          when the first word of the ALSEP frame containing the sequence of data measurements within
          this record was received at a ground tracking and receiving station on earth. Each data
          measurement has time offset (delta t) from this earth-received time. These timing offsets
          are contained in the single-record, TimeOffsets Table.</description>
        </Field_Character>
        <Field_Character>
          <name>EarthReceivedTime_Flag</name>
          <field_number>2</field_number>
          <field_location unit="byte">23</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format> 
          <description>This field is set one of two values: An asterisk (*) indicates this
          EarthReceivedTime value is from ground software clock; has a suspected transmission, data
          synchronization or tape read error in the value; or is clearly outside the expected range
          for this restoration effort. A negative sign (-) indicates this value is the
          earth-received time, and the value does not have a suspected read or transmission error or
          that it is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>stat</name>
          <field_number>3</field_number>
          <field_location unit="byte">25</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4s</field_format> 
          <description>This field contains four 1-byte flags as copied from the ARCSAV tapes. The
          four flags from left to right are: 1) unedited time sync status; 2) unedited data sync
          status; 3) edited time sync status; 4) edited data sync status. Values range from 0 to 7.
          </description>
        </Field_Character>
        <Field_Character>
          <name>tsd</name>
          <field_number>4</field_number>
          <field_location unit="byte">30</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">3</field_length>
          <field_format>%3s</field_format> 
          <description>This field contains three 1-byte flags set during reading and processing of
          the ARCSAV tapes. The left-most byte is set to 1 if a read or transmission error is
          indicated for the earth-received time. The middle byte is set to 1 if a read or
          transmission error is indicated for the data sync value. The right-most byte is set to 1
          if a read or transmission error is indicated for any of the data values.</description>
        </Field_Character>
        <Group_Field_Character>
          <name>DG-1_Group</name>
          <repetitions>31</repetitions>
          <fields>2</fields>
          <groups>0</groups>
          <group_location unit="byte">34</group_location>
          <group_length unit="byte">217</group_length>
          <Field_Character>
            <name>DG-1</name>
            <field_number>1</field_number>
            <field_location unit="byte">1</field_location>
            <data_type>ASCII_Integer</data_type>
            <field_length unit="byte">4</field_length>
            <field_format>%4d</field_format>
            <unit>DN</unit>
            <description>Measurement Number DG-1. Thirty-one Seismic scientific measurements from
            LSG ALSEP Words #4, 6 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38,
            40, 42, 44, 46, 48, 50, 52, 54, 56, 58, 60, 62, and 64. Values range from -512 to +511.
            The sampling rate was essentially constant for all 31 measurements.</description>
          </Field_Character>
          <Field_Character>
            <name>DG-1_Flag</name>
            <field_number>2</field_number>
            <field_location unit="byte">6</field_location>
            <data_type>ASCII_String</data_type>
            <field_length unit="byte">1</field_length>
            <field_format>%1s</field_format>
            <description>This field is set one of two values: An asterisk (*) indicates this data
            measurement has a suspected read or transmission error; A negative sign (-) indicates
            this data measurement does not have a suspected read or transmission error or that it
            is unknown if there was an error.</description>
          </Field_Character>
        </Group_Field_Character>
        <Field_Character>
          <name>DG-2</name>
          <field_number>5</field_number>
          <field_location unit="byte">251</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-2. One Tide scientific measurement from LSG ALSEP Word
          #25. Values range from -512 to +511.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-2_Flag</name>
          <field_number>6</field_number>
          <field_location unit="byte">256</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-3</name>
          <field_number>7</field_number>
          <field_location unit="byte">258</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-3. One Free Mode scientific measurement from LSG ALSEP
          Word #27. Values range from -512 to +511.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-3_Flag</name>
          <field_number>8</field_number>
          <field_location unit="byte">263</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-4</name>
          <field_number>9</field_number>
          <field_location unit="byte">265</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-4. One Sensor Temperature scientific measurement from
          LSG ALSEP Word #29. Values range from -512 to +511.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-4_Flag</name>
          <field_number>19</field_number>
          <field_location unit="byte">270</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-11</name>
          <field_number>11</field_number>
          <field_location unit="byte">272</field_location>
          <data_type>ASCII_Numeric_Base2</data_type>
          <field_length unit="byte">6</field_length>
          <field_format>%6d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-11. Temperature Relays Status from LSG ALSEP Word #35,
          bits 1-6. One bit for each of the six Temperature Replays numbered 1-6, where the
          most-significant (left-most) bit is Temperature Relay #1. Values are: 0 = Relay not
          selected; 1 = Relay selected.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-11_Flag</name>
          <field_number>12</field_number>
          <field_location unit="byte">279</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-12</name>
          <field_number>13</field_number>
          <field_location unit="byte">282</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-12. Mass Change Motor Status from LSG ALSEP Word #35,
          bit 7. Values are: 0 = Off; 1 = On.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-12_Flag</name>
          <field_number>14</field_number>
          <field_location unit="byte">287</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-13</name>
          <field_number>15</field_number>
          <field_location unit="byte">290</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-13. Course/Fine Screw Servo Motor Status and Slewing
          Status from LSG ALSEP Word #35, bits 8 and 9, provided as an ASCII integer. Values are: 0
          or 1 indicate Course/Fine Screw Servo Motor is Off and Slewing Status in indeterminate, 2
          = Course/Fine Screw Servo Motor is On and Slewing is Off; 3 = Course/Fine Screw Servo
          Motor is On and Slewing is On.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-13_Flag</name>
          <field_number>16</field_number>
          <field_location unit="byte">295</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-14</name>
          <field_number>17</field_number>
          <field_location unit="byte">298</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-14. Tilt Servo Motor Status from LSG ALSEP Word #35,
          bit 10. Values are: 0 = Off; 1 = On.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-14_Flag</name>
          <field_number>18</field_number>
          <field_location unit="byte">303</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-15</name>
          <field_number>19</field_number>
          <field_location unit="byte">306</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-15. Command Decoder Power Status from LSG ALSEP Word
          #37, bit 1. Values are: 0 = Off; 1 = On.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-15_Flag</name>
          <field_number>20</field_number>
          <field_location unit="byte">311</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-16</name>
          <field_number>21</field_number>
          <field_location unit="byte">314</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-16. Instrument Housing Heating Power Status from LSG
          ALSEP Word #37, bit 2. Values are: 0 = Off; 1 = On.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-16_Flag</name>
          <field_number>22</field_number>
          <field_location unit="byte">319</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-17</name>
          <field_number>23</field_number>
          <field_location unit="byte">322</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-17. Pressure Transducer Monitor Status from LSG ALSEP
          Word #37, bit 3. Values are: 0 = Off; 1 = On.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-17_Flag</name>
          <field_number>24</field_number>
          <field_location unit="byte">327</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-18</name>
          <field_number>25</field_number>
          <field_location unit="byte">330</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">4</field_length>
          <field_format>%4d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-18. Seismic Gain Mode from LSG ALSEP Word #37, bit 4.
          Values are: 0 = High; 1 = Low.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-18_Flag</name>
          <field_number>26</field_number>
          <field_location unit="byte">335</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
        <Field_Character>
          <name>DG-19</name>
          <field_number>27</field_number>
          <field_location unit="byte">337</field_location>
          <data_type>ASCII_Numeric_Base2</data_type>
          <field_length unit="byte">6</field_length>
          <field_format>%6d</field_format>
          <unit>DN</unit>
          <description>Measurement Number DG-19. Command Counter Status from LSG ALSEP Word #37,
          bits 5-10. The most-significant (left-most) bit is not used (spare) and is always set to
          1. The other five bits contain the LSG encoded command. When the LSG Command Decoder is
          powered Off (DG-15 = 0), all file bits of the LSG encoded command are indeterminate (but
          probably set to all 1's). When converted to octal, the 6-bit Base2 value ranges from 40
          to 77 (decimal 32 to 63).</description>
        </Field_Character>
        <Field_Character>
          <name>DG-19_Flag</name>
          <field_number>28</field_number>
          <field_location unit="byte">344</field_location>
          <data_type>ASCII_String</data_type>
          <field_length unit="byte">1</field_length>
          <field_format>%1s</field_format>
          <description>This field is set one of two values: An asterisk (*) indicates this data
          measurement has a suspected read or transmission error; A negative sign (-) indicates
          this data measurement does not have a suspected read or transmission error or that it
          is unknown if there was an error.</description>
        </Field_Character>
      </Record_Character>
    </Table_Character>
  </File_Area_Observational>
</Product_Observational>
