1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 == = ====== ========== ======= ======== ===== ===== ===== ======= ===== === ====== ===== ===== ===== ===== ==================================================================================== 1 1 LM xxxxxxx-0y Thermal -9999 -99.0 -99.0 -9999 -99 -99.00 -9.00 20.18 30.82 -9999 Thermal monitor reading 2 1 LM 6700031-01 1:17:32 On LRV -141 4.6 -1.4 6700031 0 15 -99.00 0.49 20.18 30.82 4510 3 1 LM 6700172-01 1:40:32 Off LRV 0 0.0 0.0 6700172 0 20 -99.00 0.65 20.18 30.82 4510 Reading adopted as DN (data number) base 4 1 LM 3374540-01 1:44:29 Inverted -9999 -99.0 -99.0 6700172 -9999 -99 -99.00 -9.00 20.18 30.82 -9999 Inverted position 5 1 ALSEP 6700026-01 2:15:16 On LRV -146 4.7 -1.3 6700172 -146 20 4.74 0.65 20.18 30.81 4510 6 1 Sta.1 6700129-01 5:08:03 On LRV -43 1.4 -4.6 6700172 -43 20 1.4 0.65 20.14 30.83 4510 7 1 SEP 6700101-01 5:56:03 On LRV -71 2.3 -3.7 6700172 -71 20 2.3 0.65 20.18 30.82 4510 8 1 LM 0001332-01 6:39:44 Off LRV -9999 -99.0 -99.0 6700172 -9999 -99 -99.00 -9.00 20.18 30.82 -9999 Instrument disturbed during measurement, data unreliable 9 1 LM 6700215-01 6:55:42 Off LRV 43 -1.4 -1.4 6700200 15 25 -0.49 0.81 20.18 30.82 4510 10 2 LM xxxxxxx-0y N/A Thermal -9999 -99.0 -99.0 6700200 -9999 -99 -99.00 -9.00 20.18 30.82 -9999 11 2 LM 6700177-01 0:17:46 Off LRV 5 -0.2 -0.2 6700200 -23 25 0.75 0.81 20.18 30.82 4510 12 2 Sta.2 6701552-01 2:18:05 On LRV 1380 -44.8 -50.8 6700200 1352 25 -43.88 0.81 20.08 30.58 4625 13 2 Sta.2a 6701235-01 3:21:09 On LRV 1063 -34.5 -40.5 6700200 1035 25 -33.59 0.81 20.09 30.60 4605 Requested by Principal Investigator, between Stations 2 and 3 14 2 Sta.3 6700497-01 4:02:40 On LRV 325 -10.5 -16.5 6700200 297 25 -9.64 0.81 20.16 30.61 4565 15 2 Sta.4 6700125-01 4:56:12 On LRV -47 1.5 -4.5 6700200 -75 25 2.43 0.81 20.20 30.67 4543 16 2 Sta.5 6700314-01 6:00:11 On LRV 142 -4.6 -10.6 6700200 114 25 -3.7 0.81 20.17 30.77 4525 17 2 LM 6700235-01 N/A Off LRV 63 -2.0 -2.0 6700250 -15 30 0.49 0.97 20.18 30.82 4510 18 3 LM xxxxxxx-0y N/A Thermal -9999 -99.0 -99.0 6700250 -9999 -99 -99.00 -9.00 20.18 30.82 -9999 19 3 LM 6700270-01 0:17:20 Off LRV 98 -3.2 -3.2 6700250 20 30 -0.65 0.97 20.18 30.82 4510 20 3 Sta.6 6701098-01 1:29:00 On LRV 926 -30.0 -36.0 6700250 848 30 27.52 0.97 20.28 30.84 4575 21 3 Sta.8 6700960-01 3:20:XX On LRV 788 -25.6 -31.6 6700250 710 30 -23.04 0.97 20.26 30.92 4575 22 3 Sta.8 6701173-01 3:45:39 Off LRV 1001 -32.5 -32.5 6700425 748 50 -24.28 1.62 20.26 30.92 4575 23 3 Sta.9 6700378-01 4:30:46 On LRV 206 -6.7 -12.7 6700425 -47 50 1.53 1.62 20.22 30.88 4515 24 3 Sta.9 6700571-01 N/A Off LRV 399 -12.9 -12.9 6700600 -29 75 0.94 2.43 20.22 30.88 4515 25 3 LM 6700107-01 5:55:58 Off LRV -65 2.1 2.1 N/A -9999 -99 -99.00 -9.00 20.18 30.82 4510 After reading 24, the gravimeter may have been damaged, reading 25 may be unreliable 26 3 LM 3374171-01 6:03:00 Inverted -9999 -99.0 -99.0 N/A -9999 -99 -99.00 -9.00 20.18 30.82 -9999 After reading 24, the gravimeter may have been damaged, reading 26 may be unreliable