/* Format of the FIPS HK Ground Calibration Data files */ OBJECT = FIELD NAME = "Time" FIELD_NUMBER = 1 BYTES = 6 DATA_TYPE = ASCII_INTEGER UNIT = "HHMMSS" DESCRIPTION = "Time Stamp (HHMMSS)" END_OBJECT = FIELD OBJECT = FIELD NAME = "Wedge" FIELD_NUMBER = 2 BYTES = 7 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "Wedge Value (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "Strip" FIELD_NUMBER = 3 BYTES = 7 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "Strip Value (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "Zigzag" FIELD_NUMBER = 4 BYTES = 7 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "Zigzag Value (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "15V_Monitor" FIELD_NUMBER = 5 BYTES = 5 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "+15V Monitor (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "M15V_Monitor" FIELD_NUMBER = 6 BYTES = 6 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "-15V Monitor (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "5V_Monitor" FIELD_NUMBER = 7 BYTES = 5 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "+5V Monitor (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "M5V_Monitor" FIELD_NUMBER = 8 BYTES = 6 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "-5V Monitor (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "3_5V_Monitor" FIELD_NUMBER = 9 BYTES = 5 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "+3.5V Monitor (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "2_5V_Monitor" FIELD_NUMBER = 10 BYTES = 5 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "+2.5V Monitor (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "Ref_Temperature" FIELD_NUMBER = 11 BYTES = 5 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "Reference Temperature (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "Temp_1" FIELD_NUMBER = 12 BYTES = 5 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "Temperature 1 (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "Temp_2" FIELD_NUMBER = 13 BYTES = 5 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "Temperature 2 (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "15kv_Board_Temp" FIELD_NUMBER = 14 BYTES = 5 DATA_TYPE = ASCII_REAL UNIT = "DN" DESCRIPTION = "+15KV Board Temperature (channel)" END_OBJECT = FIELD OBJECT = FIELD NAME = "MCP_Voltage" FIELD_NUMBER = 15 BYTES = 6 DATA_TYPE = ASCII_REAL UNIT = "VOLT" DESCRIPTION = "MCP Voltage (V)" END_OBJECT = FIELD OBJECT = FIELD NAME = "Post_Accel_Voltage" FIELD_NUMBER = 16 BYTES = 6 DATA_TYPE = ASCII_REAL UNIT = "VOLT" DESCRIPTION = "Post-acceleration Voltage (V)" END_OBJECT = FIELD OBJECT = FIELD NAME = "Deflection_System_Voltage" FIELD_NUMBER = 17 BYTES = 6 DATA_TYPE = ASCII_REAL UNIT = "VOLT" DESCRIPTION = "Deflection System Voltage (V)" END_OBJECT = FIELD