<?xml version="1.0" encoding="UTF-8" standalone="no"?>

<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1A10.sch"
  schematypens="http://purl.oclc.org/dsdl/schematron"?>
<?xml-model href="https://pds.nasa.gov/pds4/mission/mess/v1/PDS4_MESS_1B00_1020.sch"
  schematypens="http://purl.oclc.org/dsdl/schematron"?>

<Product_Observational xmlns="http://pds.nasa.gov/pds4/pds/v1" 
    xmlns:mess="http://pds.nasa.gov/pds4/mission/mess/v1" 
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" 
    xsi:schemaLocation="http://pds.nasa.gov/pds4/pds/v1 https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1A10.xsd   http://pds.nasa.gov/pds4/mission/mess/v1 https://pds.nasa.gov/pds4/mission/mess/v1/PDS4_MESS_1B00_1020.xsd">
  <Identification_Area>
    <logical_identifier>urn:nasa:pds:mess_grs_raw:data_edr:grs_sta2013144zzz_tab</logical_identifier>
    <version_id>1.0</version_id>
    <title>MESSENGER GRS Telemetry Status product: grs_sta2013144zzz_tab</title>
    <information_model_version>1.10.1.0</information_model_version>
    <product_class>Product_Observational</product_class>
    <Modification_History>
      <Modification_Detail>
        <modification_date>2018-06-08</modification_date>
        <version_id>1.0</version_id>
        <description>PDS4 migrated product</description>
      </Modification_Detail>
    </Modification_History>
  </Identification_Area>
  <Observation_Area>
    <Time_Coordinates>
      <start_date_time>2013-05-24T00:00:26.000Z</start_date_time>
      <stop_date_time>2013-05-24T23:59:26.000Z</stop_date_time>
    </Time_Coordinates>
    <Investigation_Area>
      <name>MESSENGER</name>
      <type>Mission</type>
      <Internal_Reference>
        <lid_reference>urn:nasa:pds:context:investigation:mission.messenger</lid_reference>
        <reference_type>data_to_investigation</reference_type>
      </Internal_Reference>
    </Investigation_Area>
    <Observing_System>
      <Observing_System_Component>
        <name>MESSENGER</name>
        <type>Spacecraft</type>
        <Internal_Reference>
          <lid_reference>urn:nasa:pds:context:instrument_host:spacecraft.mess</lid_reference>
          <reference_type>is_instrument_host</reference_type>
        </Internal_Reference>
      </Observing_System_Component>
      <Observing_System_Component>
        <name>Gamma Ray Spectrometer</name>
        <type>Instrument</type>
        <Internal_Reference>
          <lid_reference>urn:nasa:pds:context:instrument:grs.mess</lid_reference>
          <reference_type>is_instrument</reference_type>
        </Internal_Reference>
      </Observing_System_Component>
    </Observing_System>
    <Target_Identification>
      <name>Mercury</name>
      <type>Planet</type>
      <Internal_Reference>
        <lid_reference>urn:nasa:pds:context:target:planet.mercury</lid_reference>
        <reference_type>data_to_target</reference_type>
      </Internal_Reference>
    </Target_Identification>
    <Mission_Area>
      <mess:MESSENGER>
        <mess:mission_phase_name>Mercury Orbit Year 3</mess:mission_phase_name>
        <mess:spacecraft_clock_start_count>2/011677626</mess:spacecraft_clock_start_count>
        <mess:spacecraft_clock_stop_count>2/011763966</mess:spacecraft_clock_stop_count>
        <mess:standard_data_product_id>grs_status</mess:standard_data_product_id>
        <mess:software_name>pipe-grs2edr</mess:software_name>
        <mess:software_version_id>1.0</mess:software_version_id>
      </mess:MESSENGER>
    </Mission_Area>
  </Observation_Area>
  <File_Area_Observational>
    <File>
      <file_name>grs_sta2013144zzz.tab</file_name>
      <creation_date_time>2013-05-28T23:20:49Z</creation_date_time>
    </File>
    <Table_Character>
      <offset unit="byte">0</offset>
      <records>1440</records>
      <description>
        This table contains one set of status telemetry information gathered by
        the MESSENGER Gamma-Ray Spectrometer (GRS). A set is defined as all data
        with MET timestamps corresponding to a given Earth day. Additional details are
        contained in the EDR SIS document
      </description>
      <record_delimiter>Carriage-Return Line-Feed</record_delimiter>
      <Record_Character>
        <fields>167</fields>
        <groups>0</groups>
        <record_length unit="byte">1127</record_length>
        <Field_Character>
          <name>met</name>
          <field_number>1</field_number>
          <field_location unit="byte">1</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">12</field_length>
          <description>Mission Elapsed Time in seconds.</description>
        </Field_Character>
        <Field_Character>
          <name>orbit_number</name>
          <field_number>2</field_number>
          <field_location unit="byte">15</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            Orbit number is a unique identifier for a given orbit of
            the MESSENGER spacecraft around Mercury. Orbit number is defined as
            starting at apoherm and is calculated using the MET value and the
            appropriate SPICE kernels. Orbit numbering does not start until MESSENGER
            performs the Mercury orbit insertion. Until that time the value for orbit
            number is 0.
          </description>
        </Field_Character>
        <Field_Character>
          <name>lvps_plus5v</name>
          <field_number>3</field_number>
          <field_location unit="byte">23</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>LVPS +5 volt monitor.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_neg5v</name>
          <field_number>4</field_number>
          <field_location unit="byte">31</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>LVPS -5 volt monitor.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_plus12v</name>
          <field_number>5</field_number>
          <field_location unit="byte">39</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>LVPS +12 volt monitor.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_neg12v</name>
          <field_number>6</field_number>
          <field_location unit="byte">47</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>LVPS -12 volt monitor.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_ext_c1</name>
          <field_number>7</field_number>
          <field_location unit="byte">55</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Unused.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_ext_c2</name>
          <field_number>8</field_number>
          <field_location unit="byte">63</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Unused.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_ext_c3</name>
          <field_number>9</field_number>
          <field_location unit="byte">71</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Unused.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_ext_c4</name>
          <field_number>10</field_number>
          <field_location unit="byte">79</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Unused.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_ext_c5</name>
          <field_number>11</field_number>
          <field_location unit="byte">87</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Unused.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_plus5v_i</name>
          <field_number>12</field_number>
          <field_location unit="byte">95</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>LVPS +5V current.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_neg5v_i</name>
          <field_number>13</field_number>
          <field_location unit="byte">103</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>LVPS -5V current.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_plus12v_i</name>
          <field_number>14</field_number>
          <field_location unit="byte">111</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>LVPS +12V current.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_neg12v_i</name>
          <field_number>15</field_number>
          <field_location unit="byte">119</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>LVPS -12V current.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_temp</name>
          <field_number>16</field_number>
          <field_location unit="byte">127</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>LVPS Temperature.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_pri_i</name>
          <field_number>17</field_number>
          <field_location unit="byte">135</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>LVPS Primary Current.</description>
        </Field_Character>
        <Field_Character>
          <name>op_heater_current</name>
          <field_number>18</field_number>
          <field_location unit="byte">143</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Op-heater current.</description>
        </Field_Character>
        <Field_Character>
          <name>hvps_temp</name>
          <field_number>19</field_number>
          <field_location unit="byte">151</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HVPS Temperature.</description>
        </Field_Character>
        <Field_Character>
          <name>hvps_volt</name>
          <field_number>20</field_number>
          <field_location unit="byte">159</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HVPS Voltage.</description>
        </Field_Character>
        <Field_Character>
          <name>hvps_ref_volt</name>
          <field_number>21</field_number>
          <field_location unit="byte">167</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HVPS Reference Voltage.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_temp_1</name>
          <field_number>22</field_number>
          <field_location unit="byte">175</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel 0, HPGE Detector Temperature 1.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_temp_2</name>
          <field_number>23</field_number>
          <field_location unit="byte">183</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel 1, HPGE Detector Temperature 2.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_det_leak</name>
          <field_number>24</field_number>
          <field_location unit="byte">191</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel 2, HPGE Detector Leakage current.</description>
        </Field_Character>
        <Field_Character>
          <name>hvps_temp_2</name>
          <field_number>25</field_number>
          <field_location unit="byte">199</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel 3, HVPS Temperature.</description>
        </Field_Character>
        <Field_Character>
          <name>preamp_temp</name>
          <field_number>26</field_number>
          <field_location unit="byte">207</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel 4, Pre Amp Temperature.</description>
        </Field_Character>
        <Field_Character>
          <name>shaper_temp</name>
          <field_number>27</field_number>
          <field_location unit="byte">215</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel 5, Shaper Temperature.</description>
        </Field_Character>
        <Field_Character>
          <name>ad_temp</name>
          <field_number>28</field_number>
          <field_location unit="byte">223</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel 6, AD Temperature.</description>
        </Field_Character>
        <Field_Character>
          <name>hv_monitor</name>
          <field_number>29</field_number>
          <field_location unit="byte">231</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel 7, HV Monitor.</description>
        </Field_Character>
        <Field_Character>
          <name>ref_2_5v</name>
          <field_number>30</field_number>
          <field_location unit="byte">239</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel 8, 2.5V reference.</description>
        </Field_Character>
        <Field_Character>
          <name>ref_2_5v_div2</name>
          <field_number>31</field_number>
          <field_location unit="byte">247</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel 9, 2.5V reference divided by 2.</description>
        </Field_Character>
        <Field_Character>
          <name>ref_2_5v_div3</name>
          <field_number>32</field_number>
          <field_location unit="byte">255</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel A, 2.5V reference divided by 3.</description>
        </Field_Character>
        <Field_Character>
          <name>control_board_temp</name>
          <field_number>33</field_number>
          <field_location unit="byte">263</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC0 Channel B, Controller Board temperature.</description>
        </Field_Character>
        <Field_Character>
          <name>anneal_pri_volt</name>
          <field_number>34</field_number>
          <field_location unit="byte">271</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC1 Channel 0, Anneal primary voltage.</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_pri_volt</name>
          <field_number>35</field_number>
          <field_location unit="byte">279</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC1 Channel 1, Cooler primary voltage.</description>
        </Field_Character>
        <Field_Character>
          <name>anneal_sec_i</name>
          <field_number>36</field_number>
          <field_location unit="byte">287</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC1 Channel 2, Anneal secondary current.</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_sec_i</name>
          <field_number>37</field_number>
          <field_location unit="byte">295</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC1 Channel 3, Cooler secondary current.</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_pri_i</name>
          <field_number>38</field_number>
          <field_location unit="byte">303</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC1 Channel 4, Cooler primary current.</description>
        </Field_Character>
        <Field_Character>
          <name>anneal_pri_i</name>
          <field_number>39</field_number>
          <field_location unit="byte">311</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC1 Channel 5, Anneal primary current.</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_power_board_temp</name>
          <field_number>40</field_number>
          <field_location unit="byte">319</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC1 Channel 6, Cooler power board temperature.</description>
        </Field_Character>
        <Field_Character>
          <name>stator_temp</name>
          <field_number>41</field_number>
          <field_location unit="byte">327</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>ADC1 Channel 7, Stator temperature.</description>
        </Field_Character>
        <Field_Character>
          <name>hvac_heater</name>
          <field_number>42</field_number>
          <field_location unit="byte">335</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            Heater bit register. Bits that define states of anneal heaters.
          </description>
        </Field_Character>
        <Field_Character>
          <name>hvac_relay</name>
          <field_number>43</field_number>
          <field_location unit="byte">343</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            Relay bit register. Bits that define states of anneal
            heater relay circuits.
          </description>
        </Field_Character>
        <Field_Character>
          <name>hvac_heater_power_level</name>
          <field_number>44</field_number>
          <field_location unit="byte">351</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Heater power level.</description>
        </Field_Character>
        <Field_Character>
          <name>anneal_max_valid_temp</name>
          <field_number>45</field_number>
          <field_location unit="byte">359</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Anneal max valid temp reading limit.</description>
        </Field_Character>
        <Field_Character>
          <name>anneal_upper_temp</name>
          <field_number>46</field_number>
          <field_location unit="byte">367</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Anneal upper temp limit.</description>
        </Field_Character>
        <Field_Character>
          <name>anneal_lower_temp</name>
          <field_number>47</field_number>
          <field_location unit="byte">375</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Anneal lower temp limit.</description>
        </Field_Character>
        <Field_Character>
          <name>anneal_min_valid_temp</name>
          <field_number>48</field_number>
          <field_location unit="byte">383</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Anneal min valid temp reading limit.</description>
        </Field_Character>
        <Field_Character>
          <name>hvac_cooler_pwr</name>
          <field_number>49</field_number>
          <field_location unit="byte">391</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>DAC0 Cooler set point.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_hvps_cmd</name>
          <field_number>50</field_number>
          <field_location unit="byte">399</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            DAC1: HPGe HVPS high voltage value commanded (not actual value).
          </description>
        </Field_Character>
        <Field_Character>
          <name>cmd_hpge_hv_enable</name>
          <field_number>51</field_number>
          <field_location unit="byte">407</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Commanded HPGe HV enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_shield_hv_enable</name>
          <field_number>52</field_number>
          <field_location unit="byte">410</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Commanded HPGe HV enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_heater_state</name>
          <field_number>53</field_number>
          <field_location unit="byte">413</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Cooler Op-heater state.</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_thermostat</name>
          <field_number>54</field_number>
          <field_location unit="byte">416</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Cooler Op-heater state.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_hv_temp_ok</name>
          <field_number>55</field_number>
          <field_location unit="byte">419</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>HPGe temp in range for HV.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_temp1_enable</name>
          <field_number>56</field_number>
          <field_location unit="byte">422</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>HPGe Temp1 sensor enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_temp2_enable</name>
          <field_number>57</field_number>
          <field_location unit="byte">425</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>HPGe Temp1 sensor enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_pileup_rej_enable</name>
          <field_number>58</field_number>
          <field_location unit="byte">428</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>HPGe Temp1 sensor enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_science_mode</name>
          <field_number>59</field_number>
          <field_location unit="byte">431</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Commanded to event classification.</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_enable</name>
          <field_number>60</field_number>
          <field_location unit="byte">434</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Cooler enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_pi_enable</name>
          <field_number>61</field_number>
          <field_location unit="byte">437</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>
            Cooler PI (Proportional Integral) loop control enabled.
          </description>
        </Field_Character>
        <Field_Character>
          <name>cooler_temp_ok</name>
          <field_number>62</field_number>
          <field_location unit="byte">440</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Cooler temperature in range for operation.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_htr_cooler_overide</name>
          <field_number>63</field_number>
          <field_location unit="byte">443</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Allow anneal heater and cooler.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_htr_watchdog</name>
          <field_number>64</field_number>
          <field_location unit="byte">446</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Anneal heater watchdog enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>pulser_spectrum_enable</name>
          <field_number>65</field_number>
          <field_location unit="byte">449</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Include pulser events in spectrum.</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_science_purge</name>
          <field_number>66</field_number>
          <field_location unit="byte">452</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Purge science at end of accumulation.</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_update_mode</name>
          <field_number>67</field_number>
          <field_location unit="byte">455</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>
            Mode for immediate update of periods after command sent to
            change accumulation period (rather than delayed until end of period).
          </description>
        </Field_Character>
        <Field_Character>
          <name>in_science_mode</name>
          <field_number>68</field_number>
          <field_location unit="byte">458</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>In an accumulation/reporting cycle.</description>
        </Field_Character>
        <Field_Character>
          <name>prepare_science_data</name>
          <field_number>69</field_number>
          <field_location unit="byte">461</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Prepare to ship latest accumulation.</description>
        </Field_Character>
        <Field_Character>
          <name>watchdog_started</name>
          <field_number>70</field_number>
          <field_location unit="byte">464</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Main watchdog enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>minor_sw_version</name>
          <field_number>71</field_number>
          <field_location unit="byte">467</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Minor software version.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_temp_delta_max</name>
          <field_number>72</field_number>
          <field_location unit="byte">472</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            Maximum diode sensor temperature difference allowed
            (before safe mode enabled).
          </description>
        </Field_Character>
        <Field_Character>
          <name>hpge_temp_low_on</name>
          <field_number>73</field_number>
          <field_location unit="byte">480</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Maximum temperature to turn on HPGe HV.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_temp_high_off</name>
          <field_number>74</field_number>
          <field_location unit="byte">488</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Temperature to turn off HPGe HV.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_hv_bias_thresh</name>
          <field_number>75</field_number>
          <field_location unit="byte">496</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HPGe bias current safing threshold.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_hv_bias_check</name>
          <field_number>76</field_number>
          <field_location unit="byte">504</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Min HPGe HV to check bias.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_critical_bias</name>
          <field_number>77</field_number>
          <field_location unit="byte">512</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HPGe critical bias condition.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_crit_bias_max_hv</name>
          <field_number>78</field_number>
          <field_location unit="byte">520</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HPGe critical bias max HV.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_lvl1_saf_retries</name>
          <field_number>79</field_number>
          <field_location unit="byte">528</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HPGe level 1 safing retries.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_lvl1_wait_time</name>
          <field_number>80</field_number>
          <field_location unit="byte">536</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HPGe level 1 wait time (minutes).</description>
        </Field_Character>
        <Field_Character>
          <name>shield_hv_rate_thresh</name>
          <field_number>81</field_number>
          <field_location unit="byte">544</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Shield event rate safing threshold.</description>
        </Field_Character>
        <Field_Character>
          <name>shield_lvl1_saf_retries</name>
          <field_number>82</field_number>
          <field_location unit="byte">552</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Shield level 1 safing retries.</description>
        </Field_Character>
        <Field_Character>
          <name>shield_lvl1_wait_time</name>
          <field_number>83</field_number>
          <field_location unit="byte">560</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Shield level 1 wait time (minutes).</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_op_heater_low_limit</name>
          <field_number>84</field_number>
          <field_location unit="byte">568</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Cooler op heater lower limit.</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_op_heater_high_limit</name>
          <field_number>85</field_number>
          <field_location unit="byte">576</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Cooler op heater upper limit.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_pileup_offset</name>
          <field_number>86</field_number>
          <field_location unit="byte">584</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Offset for pileup rejection window.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_pileup_half_width</name>
          <field_number>87</field_number>
          <field_location unit="byte">592</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            Time half-width (before or after pulse zero crossing)
            for pulse pileup rejection.
          </description>
        </Field_Character>
        <Field_Character>
          <name>event_coin_offset</name>
          <field_number>88</field_number>
          <field_location unit="byte">600</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Offset for event coincidence window.</description>
        </Field_Character>
        <Field_Character>
          <name>event_coin_half_width</name>
          <field_number>89</field_number>
          <field_location unit="byte">608</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            Time half-width (before or after pulse zero crossing)
            for coincidence.
          </description>
        </Field_Character>
        <Field_Character>
          <name>neutron_ch0_min_e</name>
          <field_number>90</field_number>
          <field_location unit="byte">616</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Neutron event Channel 0 minimum energy.</description>
        </Field_Character>
        <Field_Character>
          <name>neutron_ch0_max_e</name>
          <field_number>91</field_number>
          <field_location unit="byte">624</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Neutron event Channel 0 maximum energy.</description>
        </Field_Character>
        <Field_Character>
          <name>neutron_ch1_min_e</name>
          <field_number>92</field_number>
          <field_location unit="byte">632</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Neutron event Channel 1 minimum energy.</description>
        </Field_Character>
        <Field_Character>
          <name>neutron_ch1_max_e</name>
          <field_number>93</field_number>
          <field_location unit="byte">640</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Neutron event Channel 1 maximum energy.</description>
        </Field_Character>
        <Field_Character>
          <name>pulser_ch0_min_valid</name>
          <field_number>94</field_number>
          <field_location unit="byte">648</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Valid pulser minimum energy.</description>
        </Field_Character>
        <Field_Character>
          <name>pulser_ch0_max_valid</name>
          <field_number>95</field_number>
          <field_location unit="byte">656</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Valid pulser maximum energy.</description>
        </Field_Character>
        <Field_Character>
          <name>pulser_offset</name>
          <field_number>96</field_number>
          <field_location unit="byte">664</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            Pulse height offset for computing pulser
            height-variation statistics.
          </description>
        </Field_Character>
        <Field_Character>
          <name>pulser_shift</name>
          <field_number>97</field_number>
          <field_location unit="byte">672</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Shift pulser energy for spectrum.</description>
        </Field_Character>
        <Field_Character>
          <name>config_changed</name>
          <field_number>98</field_number>
          <field_location unit="byte">680</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Configuration changed during accumulation.</description>
        </Field_Character>
        <Field_Character>
          <name>diag_packets_dropped</name>
          <field_number>99</field_number>
          <field_location unit="byte">685</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Number of diagnostic packets dropped.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_i2c_12v</name>
          <field_number>100</field_number>
          <field_location unit="byte">690</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>LVPS 12V enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_i2c_ext_pr_1</name>
          <field_number>101</field_number>
          <field_location unit="byte">693</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>LVPS External Primary 1 enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>lvps_i2c_ext_pr_2</name>
          <field_number>102</field_number>
          <field_location unit="byte">696</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>LVPS External Primary 2 enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>hvps_i2c_hv1_enable</name>
          <field_number>103</field_number>
          <field_location unit="byte">699</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>HVPS (Shield) HV enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>hvps_i2c_hv2_enable</name>
          <field_number>104</field_number>
          <field_location unit="byte">702</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Unused.</description>
        </Field_Character>
        <Field_Character>
          <name>hvps_i2c_mux_enable</name>
          <field_number>105</field_number>
          <field_location unit="byte">705</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>
            Enables/disables ADC MUX on HVPS board to provide HVPS
            housekeeping data.
          </description>
        </Field_Character>
        <Field_Character>
          <name>hvps_i2c_ref_enable</name>
          <field_number>106</field_number>
          <field_location unit="byte">708</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>
            Enables/disables use of reference HV on HVPS board to
            set/regulate HPGe HV.
          </description>
        </Field_Character>
        <Field_Character>
          <name>hvps_i2c_hv_cmd</name>
          <field_number>107</field_number>
          <field_location unit="byte">711</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HVPS I2C (Shield) HV Command.</description>
        </Field_Character>
        <Field_Character>
          <name>hw_ch0_1sec</name>
          <field_number>108</field_number>
          <field_location unit="byte">719</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Hardware channel 0 1-second event total.</description>
        </Field_Character>
        <Field_Character>
          <name>hw_ch1_1sec</name>
          <field_number>109</field_number>
          <field_location unit="byte">727</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Hardware channel 1 1-second event total.</description>
        </Field_Character>
        <Field_Character>
          <name>hw_dead_time_1sec</name>
          <field_number>110</field_number>
          <field_location unit="byte">735</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Hardware dead time 1-second event total.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_chrg_rset_1sec</name>
          <field_number>111</field_number>
          <field_location unit="byte">743</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Hardware HPGe charge reset 1-second total.</description>
        </Field_Character>
        <Field_Character>
          <name>shld_chrg_rset_1sec</name>
          <field_number>112</field_number>
          <field_location unit="byte">751</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Hardware Shield charge reset 1-second total.</description>
        </Field_Character>
        <Field_Character>
          <name>ch0_latches_detected</name>
          <field_number>113</field_number>
          <field_location unit="byte">759</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>
            Number of Channel 0 latches detected (reset at boot 
            time only).
          </description>
        </Field_Character>
        <Field_Character>
          <name>ch1_latches_detected</name>
          <field_number>114</field_number>
          <field_location unit="byte">764</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>
            Number of Channel 1 latches detected (reset at boot
            time only).
          </description>
        </Field_Character>
        <Field_Character>
          <name>cmd_hpge_max_hv</name>
          <field_number>115</field_number>
          <field_location unit="byte">769</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Commanded HPGe max HV level.</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_shield_max_hv</name>
          <field_number>116</field_number>
          <field_location unit="byte">777</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Commanded Shield max HV level.</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_hpge_hv</name>
          <field_number>117</field_number>
          <field_location unit="byte">785</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Commanded HPGe HV level.</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_shield_hv</name>
          <field_number>118</field_number>
          <field_location unit="byte">793</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Commanded Shield HV level.</description>
        </Field_Character>
        <Field_Character>
          <name>calib_avg_det_temp</name>
          <field_number>119</field_number>
          <field_location unit="byte">801</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Calibrated, averaged detector temperature.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_goal_hv_enabled</name>
          <field_number>120</field_number>
          <field_location unit="byte">809</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HPGe goal HV if HV enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_goal_temp_safe</name>
          <field_number>121</field_number>
          <field_location unit="byte">817</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HPGe goal HV if temperature safe.</description>
        </Field_Character>
        <Field_Character>
          <name>ramp_2_hpge_hv_b</name>
          <field_number>122</field_number>
          <field_location unit="byte">825</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Implements ramp to HPGE_HV_B value.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_hv_a_bias_safe</name>
          <field_number>123</field_number>
          <field_location unit="byte">833</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>HPGE_HV_A HV if bias current safe.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_hv_temp_cycle</name>
          <field_number>124</field_number>
          <field_location unit="byte">841</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Transitions to or from safe temperature.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_hv_safing_lvl</name>
          <field_number>125</field_number>
          <field_location unit="byte">849</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Current safing level.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_hv_safing_cyc</name>
          <field_number>126</field_number>
          <field_location unit="byte">854</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Times increased safing levels.</description>
        </Field_Character>
        <Field_Character>
          <name>hpge_hv_unchanged_ticks</name>
          <field_number>127</field_number>
          <field_location unit="byte">859</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Seconds at current HPGe HV.</description>
        </Field_Character>
        <Field_Character>
          <name>shld_goal_hv_enabled</name>
          <field_number>128</field_number>
          <field_location unit="byte">867</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Shield goal HV if HV enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>shld_goal_event_safe</name>
          <field_number>129</field_number>
          <field_location unit="byte">875</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Shield goal HV if event rate safe.</description>
        </Field_Character>
        <Field_Character>
          <name>ramp_2_shld_hv_b</name>
          <field_number>130</field_number>
          <field_location unit="byte">883</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Implements ramp to SHIELD_HV_B value.</description>
        </Field_Character>
        <Field_Character>
          <name>output_hvps_event_safe</name>
          <field_number>131</field_number>
          <field_location unit="byte">891</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Output to HVPS if event rate safe.</description>
        </Field_Character>
        <Field_Character>
          <name>shld_hv_state</name>
          <field_number>132</field_number>
          <field_location unit="byte">899</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Unused.</description>
        </Field_Character>
        <Field_Character>
          <name>shld_hv_safing_lvl</name>
          <field_number>133</field_number>
          <field_location unit="byte">904</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Current safing level.</description>
        </Field_Character>
        <Field_Character>
          <name>shld_hv_safing_cyc</name>
          <field_number>134</field_number>
          <field_location unit="byte">909</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Number of times safing level was increased.</description>
        </Field_Character>
        <Field_Character>
          <name>last_opcode</name>
          <field_number>135</field_number>
          <field_location unit="byte">914</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Last command opcode received.</description>
        </Field_Character>
        <Field_Character>
          <name>shld_hv_unchanged_ticks</name>
          <field_number>136</field_number>
          <field_location unit="byte">919</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Seconds at current HPGe HV.</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_temp_setpoint</name>
          <field_number>137</field_number>
          <field_location unit="byte">927</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Cooler temperature set point.</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_power</name>
          <field_number>138</field_number>
          <field_location unit="byte">935</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Cooler power (manual or PI loop control).</description>
        </Field_Character>
        <Field_Character>
          <name>cooler_pi_prop</name>
          <field_number>139</field_number>
          <field_location unit="byte">943</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            Cooler PI (Proportional Integral) loop proportional gain (*256).
          </description>
        </Field_Character>
        <Field_Character>
          <name>cooler_pi_integral</name>
          <field_number>140</field_number>
          <field_location unit="byte">951</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            Cooler PI (Proportional Integral) loop integral gain (*256).
          </description>
        </Field_Character>
        <Field_Character>
          <name>cooler_pi_offset</name>
          <field_number>141</field_number>
          <field_location unit="byte">959</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            Cooler PI (Proportional Integral) loop offset for output.
          </description>
        </Field_Character>
        <Field_Character>
          <name>cooler_pi_max_err</name>
          <field_number>142</field_number>
          <field_location unit="byte">967</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>PI loop max error to enable integration.</description>
        </Field_Character>
        <Field_Character>
          <name>accum_time_left</name>
          <field_number>143</field_number>
          <field_location unit="byte">975</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Time left in current accumulation.</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_report_period</name>
          <field_number>144</field_number>
          <field_location unit="byte">983</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Commanded reporting period.</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_accum_time</name>
          <field_number>145</field_number>
          <field_location unit="byte">991</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Commanded accumulation time.</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_ship_mode</name>
          <field_number>146</field_number>
          <field_location unit="byte">999</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Commanded science ship mode.</description>
        </Field_Character>
        <Field_Character>
          <name>a2d_ship_mode</name>
          <field_number>147</field_number>
          <field_location unit="byte">1007</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Microphonics ship mode (compressed).</description>
        </Field_Character>
        <Field_Character>
          <name>science_priority</name>
          <field_number>148</field_number>
          <field_location unit="byte">1015</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Base value for science ApIDs.</description>
        </Field_Character>
        <Field_Character>
          <name>status_interval</name>
          <field_number>149</field_number>
          <field_location unit="byte">1023</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>
            Status interval (seconds). Defines interval at which
            status is reported. Not an accumulation interval. All status fields are
            stationary values.
          </description>
        </Field_Character>
        <Field_Character>
          <name>macro_free_blocks</name>
          <field_number>150</field_number>
          <field_location unit="byte">1031</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Free blocks for macros.</description>
        </Field_Character>
        <Field_Character>
          <name>tlm_volume</name>
          <field_number>151</field_number>
          <field_location unit="byte">1039</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Telemetry volume (kB).</description>
        </Field_Character>
        <Field_Character>
          <name>watch_addr</name>
          <field_number>152</field_number>
          <field_location unit="byte">1047</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Debug watch address.</description>
        </Field_Character>
        <Field_Character>
          <name>watch_mem</name>
          <field_number>153</field_number>
          <field_location unit="byte">1055</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Debug watch page.</description>
        </Field_Character>
        <Field_Character>
          <name>watch_byte1</name>
          <field_number>154</field_number>
          <field_location unit="byte">1063</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Debug watch byte 1.</description>
        </Field_Character>
        <Field_Character>
          <name>watch_byte2</name>
          <field_number>155</field_number>
          <field_location unit="byte">1068</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Debug watch byte 2.</description>
        </Field_Character>
        <Field_Character>
          <name>sw_version</name>
          <field_number>156</field_number>
          <field_location unit="byte">1073</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Major software version.</description>
        </Field_Character>
        <Field_Character>
          <name>alarm_id</name>
          <field_number>157</field_number>
          <field_location unit="byte">1078</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Last alarm ID.</description>
        </Field_Character>
        <Field_Character>
          <name>alarm_count</name>
          <field_number>158</field_number>
          <field_location unit="byte">1083</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">6</field_length>
          <description>Total alarm count (can be reset by command).</description>
        </Field_Character>
        <Field_Character>
          <name>alarm_type</name>
          <field_number>159</field_number>
          <field_location unit="byte">1091</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Last alarm type.</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_executed</name>
          <field_number>160</field_number>
          <field_location unit="byte">1094</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Number of commands executed (can be reset by command).</description>
        </Field_Character>
        <Field_Character>
          <name>cmd_rejected</name>
          <field_number>161</field_number>
          <field_location unit="byte">1099</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Number of commands rejected (can be reset by command).</description>
        </Field_Character>
        <Field_Character>
          <name>macro_cmd_exec</name>
          <field_number>162</field_number>
          <field_location unit="byte">1104</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Macro commands executed (can be reset by command).</description>
        </Field_Character>
        <Field_Character>
          <name>macro_cmd_reject</name>
          <field_number>163</field_number>
          <field_location unit="byte">1109</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Macro commands rejected (can be reset by command).</description>
        </Field_Character>
        <Field_Character>
          <name>macro_id</name>
          <field_number>164</field_number>
          <field_location unit="byte">1114</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">3</field_length>
          <description>Last macro ID.</description>
        </Field_Character>
        <Field_Character>
          <name>macro_learn</name>
          <field_number>165</field_number>
          <field_location unit="byte">1119</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Macro learning mode.</description>
        </Field_Character>
        <Field_Character>
          <name>mem_write_enable</name>
          <field_number>166</field_number>
          <field_location unit="byte">1122</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Memory writing enabled.</description>
        </Field_Character>
        <Field_Character>
          <name>mon_response</name>
          <field_number>167</field_number>
          <field_location unit="byte">1125</field_location>
          <data_type>ASCII_Integer</data_type>
          <field_length unit="byte">1</field_length>
          <description>Monitor response.</description>
        </Field_Character>
      </Record_Character>
    </Table_Character>
  </File_Area_Observational>
  <File_Area_Observational_Supplemental>
    <File>
      <file_name>grs_sta2013144zzz.lbl</file_name>
    </File>
    <Stream_Text>
      <offset unit="byte">0</offset>
      <parsing_standard_id>PDS3</parsing_standard_id>
      <description>Original PDS3 label</description>
      <record_delimiter>Carriage-Return Line-Feed</record_delimiter>
    </Stream_Text>
  </File_Area_Observational_Supplemental>
</Product_Observational>