<?xml version="1.0" encoding="UTF-8"?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1D00.sch"
   schematypens="http://purl.oclc.org/dsdl/schematron"?>
<Product_Observational
   xmlns="http://pds.nasa.gov/pds4/pds/v1"
   xmlns:pds="http://pds.nasa.gov/pds4/pds/v1"
   xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
   xsi:schemaLocation="
      http://pds.nasa.gov/pds4/pds/v1
      https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1D00.xsd
">

       <Identification_Area>
             <logical_identifier>urn:nasa:pds:mess-rs-raw:data-tnf:071551935sc236dss14_tnf</logical_identifier>
             <version_id>1.0</version_id>
             <title>MESSENGER  Radio Science Tracking and Navigation File (TNF)
                    From: 2007-06-04T18:07:51Z To 2007-06-05T05:20:53Z
                    DSN: 14
             </title>
             <information_model_version>1.13.0.0</information_model_version>
             <product_class>Product_Observational</product_class>
             <Citation_Information>
                   <author_list>Verma, A. K.; Perry, M. E.; Lemoine, F. G.; Smith, D. E.; Ensor, S.; Reid, M. R.</author_list>
                   <publication_year>2020</publication_year>
                   <description>MESSENGER Radio Science Tracking and Navigation File (TNF)</description>
             </Citation_Information>
             <Modification_History>
                   <Modification_Detail>
                         <modification_date>2020-10-12</modification_date>
                         <version_id>1.0</version_id>
                         <description>
                                This data file has been migrated from PDS3 PRODUCT_ID 071551935SC236DSS14_234
                                in data set MESS-V/H-RSS-1-EDR-RAWDATA-V1.0 to PDS4. The data file has been sorted according
                                to data type and a new PDS4 label was created as part of the migration process.
                         </description>
                  </Modification_Detail>
             </Modification_History>
       </Identification_Area>
       <Observation_Area>
             <Time_Coordinates>
                   <start_date_time>2007-06-04T18:07:51Z</start_date_time>
                   <stop_date_time>2007-06-05T05:20:53Z</stop_date_time>
             </Time_Coordinates>
             <Primary_Result_Summary>
                   <purpose>Science</purpose>
                   <processing_level>Raw</processing_level>
                   <description>MESSENGER raw radio tracking data</description>
                   <Science_Facets>
                           <discipline_name>Radio Science</discipline_name>
                   </Science_Facets>
             </Primary_Result_Summary>
             <Investigation_Area>
                   <name>MErcury Surface, Space ENvironment, GEochemistry, and Ranging Mission</name>
                   <type>Mission</type>
                   <Internal_Reference>
                         <lid_reference>urn:nasa:pds:context:investigation:mission.messenger</lid_reference>
                         <reference_type>data_to_investigation</reference_type>
                   </Internal_Reference>
             </Investigation_Area>
             <Observing_System>
                   <Observing_System_Component>
                         <name>MESSENGER</name>
                         <type>Spacecraft</type>
                         <Internal_Reference>
                               <lid_reference>urn:nasa:pds:context:instrument_host:spacecraft.mess</lid_reference>
                               <reference_type>is_instrument_host</reference_type>
                         </Internal_Reference>
                   </Observing_System_Component>
                   <Observing_System_Component>
                         <name>RSS</name>
                         <type>Instrument</type>
                         <Internal_Reference>
                               <lid_reference>urn:nasa:pds:context:instrument:rss.mess</lid_reference>
                               <reference_type>is_instrument</reference_type>
                         </Internal_Reference>
                   </Observing_System_Component>
                   <Observing_System_Component>
                         <name>NASA Deep Space Network</name>
                         <type>Observatory</type>
                         <Internal_Reference>
                               <lid_reference>urn:nasa:pds:context:facility:observatory.dsn</lid_reference>
                               <reference_type>is_facility</reference_type>
                         </Internal_Reference>
                   </Observing_System_Component>                                                                                                                                                   
                   <Observing_System_Component>
                         <name>DSN Instrumentation</name>
                         <type>Instrument</type>
                         <Internal_Reference>
                               <lid_reference>urn:nasa:pds:context:instrument:dsn.rss</lid_reference>
                               <reference_type>is_instrument</reference_type>
                         </Internal_Reference>
                   </Observing_System_Component>
                    
                   <Observing_System_Component>
                         <name>DSN Antenna DSS 14</name>
                         <type>Telescope</type>
                         <Internal_Reference>
                               <lid_reference>urn:nasa:pds:context:telescope:goldstone.dss14_70m</lid_reference>
                               <reference_type>is_telescope</reference_type>
                         </Internal_Reference>
                   </Observing_System_Component>
             </Observing_System>
             <Target_Identification>
                   <name>Venus</name>
                   <type>Planet</type>
                   <Internal_Reference>
                         <lid_reference>urn:nasa:pds:context:target:planet.venus</lid_reference>
                         <reference_type>data_to_target</reference_type>
                   </Internal_Reference>
             </Target_Identification>
       </Observation_Area>
       <Reference_List>
            <Internal_Reference>
                  <lid_reference>urn:nasa:pds:radiosci.documentation:dsn.trk-2-34:2002-12-15</lid_reference>
                  <reference_type>data_to_document</reference_type>
                  <comment>
                      Reference document for the Tracking and Navigation File (TNF) data.
                      For data collected earlier or later than this document, consult other
                      document products in the same collection.
 
                      IMPORTANT: Records delivered originally by the DSN were in time order, with records for
                      different TNF data types interleaved.  Retaining that structure would have made the PDS
                      label many times larger than the data file itself.  To keep the size of the label 
                      manageable, the original file was sorted so that all records of a single TNF data type are
                      together.  The blocks of homogeneous records were then concatenated -- TNF data type 0,
                      followed by TNF data type 1, ... followed by TNF data type 17.  When there were no records of
                      a given TNF data type, that block was omitted.  Within each block, the records remain in
                      time order.  The label is still long, since each block is a Table_Binary with
                      many records containing many fields.  But there will never be more than 18 blocks and
                      never more than 18 Table_Binary definitions.  The document referenced here correctly
                      describes the record formats.  Note, however, that the records are no longer in absolute
                      time order.  They are in time order within each block and the blocks are ordered by
                      TNF data type.
                  </comment>
            </Internal_Reference>
            <Source_Product_External>
                  <external_source_product_identifier>MESS-V/H-RSS-1-EDR-RAWDATA-V1.0:071551935SC236DSS14_234</external_source_product_identifier>
                  <reference_type>data_to_raw_source_product</reference_type>
                  <curating_facility>PDS Geosciences Node</curating_facility>
                  <description>
                      The value for external_source_product_identifier is constructed from the
                      PDS3 DATA_SET_ID, an ASCII colon character, and the PDS3 PRODUCT_ID.
                  </description>                                                                     
            </Source_Product_External>
       </Reference_List>
       <File_Area_Observational>
             <File>
                   <file_name>071551935sc236dss14_tnf.dat</file_name>
                   <creation_date_time>2020-10-12T11:05:43</creation_date_time>
                   <file_size unit="byte">25532592</file_size>
                   <md5_checksum>317b51ed35aca584d33f03068613ad98</md5_checksum>
             </File>
             <Table_Binary>
                   <name>Uplink Carrier Phase              (Data Type 00)</name>
                   <offset unit="byte">0</offset>
                   <records>40376</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">182</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 132</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>32</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 132 for uplink data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">70</group_length>
                              <Field_Binary>
                                   <name>secondary_chdo_type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Type attribute of the secondary CHDO.  The following values are possible:
                                            132 = uplink data types;
                                            133 = downlink data types;
                                            134 = derived data types;
                                            135 = interferometric data types;
                                            136 = filtered data types.
                                         Set to 132 for this Table.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>secondary_chdo_length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Length attribute of the secondary CHDO.  
                                         Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                         The following values are possible:
                                             66 = uplink data types;
                                            110 = downlink data types;
                                            124 = derived data types;
                                             88 = interferometric data types;
                                             98 = filtered data types.
                                          Set to 66 for this Table.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>orig_id</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Originator ID.
                                         Indicates where this SFDU originated. 
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>last_modifier_id</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Last modifier ID.
                                         Indicates where the contents of this SFDU were last modified. 
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve1a</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Reserved for future expansion of the next field (scft_id).
                                         A value of 0 is expected.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>scft_id</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Spacecraft number.  Values between 1 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>upl_rec_seq_num</name>
                                   <field_number>7</field_number>
                                   <field_location unit="byte">9</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <description>
                                       Uplink record sequence number (UPL RSN).
                                       This is the record sequence number reported by the uplink subsystem (UPL) equipment.
                                         Values between 0 and 2**32-1 are allowed.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>rec_seq_num</name>
                                   <field_number>8</field_number>
                                   <field_location unit="byte">13</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <description>
                                         Record sequence number (RSN).
                                         Begins with zero, then increments by one for each successive uplink tracking 
                                         SFDU of the same data type.  Wraps around from 2**32-1 to zero. Value is reset 
                                         to zero when the data processing system software is restarted.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>year</name>
                                   <field_number>9</field_number>
                                   <field_location unit="byte">17</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Time tag -- year
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>doy</name>
                                   <field_number>10</field_number>
                                   <field_location unit="byte">19</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Time tag -- day of year
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sec</name>
                                   <field_number>11</field_number>
                                   <field_location unit="byte">21</field_location>
                                   <data_type>IEEE754MSBDouble</data_type>
                                   <field_length unit="byte">8</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Time tag -- seconds of day
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rct_day</name>
                                   <field_number>12</field_number>
                                   <field_location unit="byte">29</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>day</unit>
                                   <description>
                                         Record creation time -- days since 1 January 1958.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rct_msec</name>
                                   <field_number>13</field_number>
                                   <field_location unit="byte">31</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <field_format>%10d</field_format>
                                   <unit>millisecond</unit>
                                   <description>
                                         Record creation time -- milliseconds of day
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_dss_id</name>
                                   <field_number>14</field_number>
                                   <field_location unit="byte">35</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink antenna number.  A value between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_band</name>
                                   <field_number>15</field_number>
                                   <field_location unit="byte">36</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink frequency band.
                                            0 = Unknown; 
                                            1 = S-band; 
                                            2 = X-band; 
                                            3 = Ka-band; 
                                            4 = Ku-band; 
                                            5 = L-band
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_assembly_num</name>
                                   <field_number>16</field_number>
                                   <field_location unit="byte">37</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink Assembly Number.
                                         Note that this is to allow for potential future cases where there might be more 
                                         than one uplink of the same band at the same antenna.
                                            0 = Invalid/unknown; 
                                            1 = S- or X-band uplink; 
                                            2 = Ka-band uplink
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_num</name>
                                   <field_number>17</field_number>
                                   <field_location unit="byte">38</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmitter number.  Value depends on transmitter used.  
                                         Values between 0 and 3 are allowed;  0 indicates unknown.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_stat</name>
                                   <field_number>18</field_number>
                                   <field_location unit="byte">39</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmit status.
                                            0 = Not transmitting out the horn; 
                                            1 = Transmitting out the horn; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_mode</name>
                                   <field_number>19</field_number>
                                   <field_location unit="byte">40</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmitter mode.
                                            0 = Low power; 
                                            1 = High power; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>cmd_modul_stat</name>
                                   <field_number>20</field_number>
                                   <field_location unit="byte">41</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Command modulation status.
                                            0 = OFF; 
                                            1 = ON; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rng_modul_stat</name>
                                   <field_number>21</field_number>
                                   <field_location unit="byte">42</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Ranging modulation status.
                                            0 = OFF; 
                                            1 = ON; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>fts_vld_flag</name>
                                   <field_number>22</field_number>
                                   <field_location unit="byte">43</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Frequency and Timing (FTS) validity.
                                            0 = Equipment is not synced with FTS; 
                                            1 = Equipment is synced with FTS
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_software_version</name>
                                   <field_number>23</field_number>
                                   <field_location unit="byte">44</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink Software version number.
                                         Gives the version major op code for the uplink software.
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_time_tag_delay</name>
                                   <field_number>24</field_number>
                                   <field_location unit="byte">45</field_location>
                                   <data_type>IEEE754MSBDouble</data_type>
                                   <field_length unit="byte">8</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Transmit time tag delay.
                                         Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                         Values 0.0 to 1.0 are allowed.  Value of -1.0 indicates invalid (or not provided).
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_zheight_corr</name>
                                   <field_number>25</field_number>
                                   <field_location unit="byte">53</field_location>
                                   <data_type>IEEE754MSBSingle</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Uplink Z-height correction.
                                         Values -1.0 to 1.0 are possible.  Value -99.0 indicates invalid.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>mod_day</name>
                                   <field_number>26</field_number>
                                   <field_location unit="byte">57</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Last modification time -- days since 1 January 1958.
                                         Values 0 to 2**16-1 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>mod_msec</name>
                                   <field_number>27</field_number>
                                   <field_location unit="byte">59</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <unit>milliseconds</unit>
                                   <description>
                                         Last modification time -- milliseconds of day.
                                         Values 0 to 86400999 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>version_num</name>
                                   <field_number>28</field_number>
                                   <field_location unit="byte">63</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Version number of the assembly that generated the data. 
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sub_version_num</name>
                                   <field_number>29</field_number>
                                   <field_location unit="byte">64</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Sub-version number of the assembly that generated the data.
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sub_sub_version_num</name>
                                   <field_number>30</field_number>
                                   <field_location unit="byte">65</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Sub-sub-version number of the assembly that generated the data.
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve1b</name>
                                   <field_number>31</field_number>
                                   <field_location unit="byte">66</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <field_format>%1d</field_format>
                                   <description>
                                         Reserved. One byte.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve4a</name>
                                   <field_number>32</field_number>
                                   <field_location unit="byte">67</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <field_format>%10d</field_format>
                                   <description>
                                         Reserved. Four bytes.
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Uplink Carrier Phase CHDO (Data Type 0)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>19</fields>
                              <groups>0</groups>
                              <description>Uplink Carrier Phase CHDO (Data Type 0)</description>
                              <group_location unit="byte">103</group_location>
                              <group_length unit="byte">80</group_length>
                              <Field_Binary>
                                    <name>chdo_type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          Type attribute of the uplink carrier phase data CHDO.
                                          A value 10 is expected, indicating that the CHDO contains binary data.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>chdo_length</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">3</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          Length attribute of the uplink carrier phase data CHDO value field.
                                          Number of bytes after this item.  A value of 76 is expected.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ul_hi_phs_cycles</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>UnsignedMSB4</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <field_format>%10d</field_format>
                                    <description>
                                          High part phase data: total integer phase cycles divided by 2**32.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ul_lo_phs_cycles</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>UnsignedMSB4</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          Low part phase data: total integer phase cycles modulo 2**32.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ul_frac_phs_cycles</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB4</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <field_format>%10d</field_format>
                                    <description>
                                          Fractional phase data cycles: fractional phase cycles multiplied by 2**32
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ramp_freq</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">17</field_location>
                                    <data_type>IEEE754MSBDouble</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>hertz</unit>
                                    <description>
                                          The base frequency of a ramped uplink transmission.
                                          Values 2.0e9 to 34.7e9 are expected.  A value of 0. indicates an invalid or unknown value.
                                          Precision varies with band (phase data give higher precision):   
                                             S-band  = 0.5 microHz; 
                                             X-band  = 1.6 microHz;
                                             Ka-band = 7.7 microHz
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ramp_rate</name>
                                    <field_number>7</field_number>
                                    <field_location unit="byte">25</field_location>
                                    <data_type>IEEE754MSBDouble</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>Hz/s</unit>
                                    <description>
                                          Ramp rate of an uplink transmission.  
                                          Allowed values are -3.2e5 to 3.2e5.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>transmit_switch_stat</name>
                                    <field_number>8</field_number>
                                    <field_location unit="byte">33</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <field_format>%3d</field_format>
                                    <description>
                                          Transmitter switch status.
                                             0 = Antenna; 
                                             1 = Water load; 
                                             2 = Invalid/unknown
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ramp_type</name>
                                    <field_number>9</field_number>
                                    <field_location unit="byte">34</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <field_format>%3d</field_format>
                                    <description>
                                          Ramp type.
                                             0 = Snap; 
                                             1 = Start of new ramp; 
                                             2 = Medial report; 
                                             3 = Periodic report; 
                                             4 = End of ramps; 
                                             5 = Ramping terminated by operator; 
                                             6 = Invalid/unknown
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>transmit_op_pwr</name>
                                    <field_number>10</field_number>
                                    <field_location unit="byte">35</field_location>
                                    <data_type>IEEE754MSBSingle</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <unit>watt</unit>
                                    <description>
                                          Transmitter output power.
                                          Values 0. to 500,000.0 are allowed.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>sup_data_id</name>
                                    <field_number>11</field_number>
                                    <field_location unit="byte">39</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <description>
                                          Support data ID.  Name of the frequency predicts set used.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>sup_data_rev</name>
                                    <field_number>12</field_number>
                                    <field_location unit="byte">47</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <field_format>%8s</field_format>
                                    <description>
                                          Support data revision. Revision of the frequency predicts set used.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>prdx_time_offset</name>
                                    <field_number>13</field_number>
                                    <field_location unit="byte">55</field_location>
                                    <data_type>IEEE754MSBDouble</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>second</unit>
                                    <description>
                                          Predicts time offset.  Seconds added to current time.
                                          Values -31,536,000.0 to 31,536,000.0 are allowed.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>prdx_freq_offset</name>
                                    <field_number>14</field_number>
                                    <field_location unit="byte">63</field_location>
                                    <data_type>IEEE754MSBDouble</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>hertz</unit>
                                    <description>
                                          Predicts frequency offset.  Hz added to predicted value.
                                          Values -4.8e6 to 4.8e6 are allowed.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>time_tag_corr_flag</name>
                                    <field_number>15</field_number>
                                    <field_location unit="byte">71</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          Time tag correction flag. Indicates results of validation of the block time tag.
                                             0 = No validation attempted; 
                                             1 = Validated, no change; 
                                             2 = Validated, changed
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>type_time_corr_flag</name>
                                    <field_number>16</field_number>
                                    <field_location unit="byte">72</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          Type of time tag correction flag. Indicates what type of time tag correction was made.
                                             0 = No correction; 
                                             1 = Year correction; 
                                             2 = DOY correction; 
                                             3 = Both Year and DOY correction
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>fabricated_sfdu_flag</name>
                                    <field_number>17</field_number>
                                    <field_location unit="byte">73</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          Fabricated SFDU Flag. Indicates whether this SFDU was artificially 
                                          fabricated in support of 3-way ranging. 
                                             0 = Originally generated by UPL and validated by TTC software; 
                                             1 = Fabricated by TTC software
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>reserve1c</name>
                                    <field_number>18</field_number>
                                    <field_location unit="byte">74</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          Reserved. One byte.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>reserve6a</name>
                                    <field_number>19</field_number>
                                    <field_location unit="byte">75</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">6</field_length>
                                    <description>
                                          Reserved. Six bytes.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>Downlink Carrier Phase            (Data Type 01)</name>
                   <offset unit="byte">7348432</offset>
                   <records>31513</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">378</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 133</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>49</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 133 for downlink data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">114</group_length>
                              <Field_Binary>
                                  <name>secondary_chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the secondary CHDO.  The following values are possible:
                                         132 = uplink data types;
                                         133 = downlink data types;
                                         134 = derived data types;
                                         135 = interferometric data types;
                                         136 = filtered data types.
                                      Set to 133 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>secondary_chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the secondary CHDO.  
                                      Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                      The following values are possible:
                                          66 = uplink data types;
                                         110 = downlink data types;
                                         124 = derived data types;
                                          88 = interferometric data types;
                                          98 = filtered data types.
                                      Set to 110 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>orig_id</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Originator ID.
                                      Indicates where this SFDU originated. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_modifier_id</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last modifier ID.
                                      Indicates where the contents of this SFDU were last modified. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved for future expansion of the next field (scft_id).
                                      A value of 0 is expected.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_id</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">8</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft number.  Values between 1 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dtt_rec_seq_num</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      RDownlink record sequence number (DTT RSN) -- the number reported by
                                      the downlink subsystem (DTT) equipment.  Values between 0 and 2**32-1
                                      are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rec_seq_num</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Record sequence number (RSN).
                                      Begins with zero, then increments by one for each successive downlink tracking 
                                      SFDU of the same data type.  Wraps around from 2**32-1 to zero. Value is reset 
                                      to zero when the data processing system software is restarted.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>year</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Time tag -- year
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>doy</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">19</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Time tag -- day of year.
                                      Values between 1 and 366 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sec</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">21</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Time tag -- seconds of day.
                                      Values between 0.00 and 86400.99 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_day</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Record creation time -- days since 1 January 1958.
                                      Values between 0 and 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_msec</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Record creation time -- milliseconds of day.
                                      Values between 0 and 86400999 are allowed.
                                  </description>
                              </Field_Binary>                              
                              <Field_Binary>
                                  <name>dl_dss_id</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink antenna number.
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_band</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">36</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink frequency band.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band;
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_chan_num</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink channel number.
                                      Values between 1 and 24 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_mode</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">38</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Predicts mode -- the predicts subset used by downlink channel.
                                         0 = No Predicts; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_prdx_stn</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">39</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station used for predicts.  Valid only if prdx_mode (field 17) is 2 or 3. 
                                      Values 0 to 255 are allowed; a value 0 means that the number is unknown 
                                      or not valid (e.g., no uplink).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band_dl</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">40</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band assumed by downlink.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_delay</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">41</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Array delay value -- time delay added to path by arraying equipment.  
                                      Obtained from arraying equipment.  Any measurements include this delay.  
                                      Values 0.0 to 1.0 are allowed.  
                                      Valid only if Array Flag (array_flag is field 23) is non-zero.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fts_vld_flag</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">49</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Frequency and Timing (FTS) validity.
                                         0 = Equipment is not synced with FTS; 
                                         1 = Equipment is synced with FTS
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_lock_stat</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">50</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier lock status.
                                         0 = Off; 
                                         1 = Open (only using predicts); 
                                         2 = Acquiring, FFT Search; 
                                         3 = Acquiring, Waiting for Lock Decision; 
                                         4 = In Lock; 
                                         5 = Out of Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_flag</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Array flag.
                                         0 = Not arrayed; 
                                         1 = Arrayed with Full Spectrum Processing subsystem #1; 
                                         2 = Arrayed with Full Spectrum Processing subsystem #2
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>polarization</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">52</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Polarization.
                                         0 = RCP; 
                                         1 = LCP;
                                         2 = Unknown;
                                         3 = Not applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>diplxr_stat</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Diplexer status.
                                         0 = Low noise; 
                                         1 = Diplexed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_num</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">54</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Number.
                                      Values 0-4 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rf_if_chan_num</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      RF-to-IF Downconverter Channel number.
                                      Values 1 or 2 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>if_num</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">56</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      IF input number -- defines path into downlink channel.
                                      Values 1 to 3 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_time_tag_delay</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Receive time tag delay.  
                                      Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).
                                      Values 0.0 to 1.0 are allowed; value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_zheight_corr</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Downlink Z-height correction. 
                                      Values -1.000 to 1.000 are allowed; value -99.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_ul_stn</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated uplink station.  
                                      The uplink station per the validation process.  
                                      Values 0 to 255 are allowed; value 0 means that the antenna is unknown or not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dop_mode</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">70</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated Doppler mode.  
                                         0 = Unknown or not applicable; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_scft_coh</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">71</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated spacecraft coherency.  
                                         0 = Unknown or not applicable; 
                                         1 = Coherent; 
                                         2 = Non-coherent; 
                                         3 = Transponded, non-coherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_lock</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">72</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder lock status.
                                         0 = Unknown; 
                                         1 = Out-of-lock; 
                                         2 = In Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_num</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">73</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder number.
                                      Values 1 to 5 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_software_version</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">74</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink software version number -- the DCC software version major op code.
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_freq</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">75</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Spacecraft one-way frequency.
                                      Values 2.0e9 to 32.3e9 are allowed; value 0.0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_delay</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Spacecraft transponder delay (the coherent ranging delay).  
                                      Values 0.0 to 1.0 are allowed; value -1.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_num</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">91</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- numerator.
                                      Values 0 to 2**32-1 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_den</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">95</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- denominator.
                                      Values 0 to 2**32-1 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_twnc_stat</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">99</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft two-way non-coherent (TWNC) status.
                                         0 = Unknown;
                                         1 = OFF; 
                                         2 = ON
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_type</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">100</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft oscillator type.
                                         0 = Unknown; 
                                         1 = AUX OSC (auxiliary oscillator); 
                                         2 = USO (ultra-stable oscillator)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_day</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">101</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Last modification time -- days since 1 January 1958.
                                      Values 0 to 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_msec</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">103</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Last modification time -- milliseconds of day.
                                      Values 0 to 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>version_num</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">107</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Version number of the assembly that generated the data. 
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_version_num</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">108</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-version number of the assembly that generated the data.
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_sub_version_num</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-sub-version number of the assembly that generated the data.
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_corr_value</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">110</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Correction Value -- indicates results of validation of LNA number. 
                                      Values 1 to 4 are allowed and should be substituted for lna_num (field 26).
                                      Value 0 indicates no validation or correction was made.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve4</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">111</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Reserved. Four bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Downlink Carrier Phase CHDO (Data Type 1)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>59</fields>
                              <groups>0</groups>
                              <description>Downlink Carrier Phase CHDO (Data Type 1)</description>
                              <group_location unit="byte">147</group_location>
                              <group_length unit="byte">232</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the downlink carrier phase data CHDO. 
                                      Set to 10 because the CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the downlink carrier phase data CHDO value field.
                                      Number of bytes after this item.  Set to 228 for this CHDO.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_loop_bw</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Carrier tracking loop bandwidth.
                                      Values from 0.1 to 50.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pcn0</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Ratio of carrier power (Pc) to noise power spectral density (N0).
                                      Values from 0.0 to 90.0 are allowed; value -300.0 indicates no signal.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pcn0_resid</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Pc/N0 residual -- actual value minus predicted value.
                                      Values -90.0 to 90.0 are allowed; value -300.0 indicates
                                      no signal or carrier is suppressed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pdn0</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Ratio of data power (Pd) to noise power spectral density (N0).  
                                      Values 0.0 to 90.0 are allowed; value -300.0 indicates no signal.</description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pdn0_resid</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">21</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Pd/N0 residual -- actual value minus predicted value.
                                      Values -90.0 to 90.0 are allowed; value -300.0 indicates no signal.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>system_noise_temp</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>K</unit>
                                  <description>
                                      System Noise Temperature.
                                      Values 0.1 to 2000.0 are allowed.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_0</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 0 -- high part.
                                      Total integer phase in cycles at (time tag + 0.0 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_0</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 0 -- low part.
                                      Total integer phase in cycles at (time tag + 0.0 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_0</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 0 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.0 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              
                              <Field_Binary>
                                  <name>phs_hi_1</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">41</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 1 -- high part.
                                      Total integer phase in cycles at (time tag + 0.1 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_1</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">45</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 1 -- low part.
                                      Total integer phase in cycles at (time tag + 0.1 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_1</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">49</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 1 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.1 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              
                              <Field_Binary>
                                  <name>phs_hi_2</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 2 -- high part.
                                      Total integer phase in cycles at (time tag + 0.2 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_2</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 2 -- low part.
                                      Total integer phase in cycles at (time tag + 0.2 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_2</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">61</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 2 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.2 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_3</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 3 -- high part.
                                      Total integer phase in cycles at (time tag + 0.3 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_3</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 3 -- low part.
                                      Total integer phase in cycles at (time tag + 0.3 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_3</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">73</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 3 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.3 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_4</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">77</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 4 -- high part.
                                      Total integer phase in cycles at (time tag + 0.4 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_4</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">81</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 4 -- low part.
                                      Total integer phase in cycles at (time tag + 0.4 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_4</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">85</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 4 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.4 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                            
                              <Field_Binary>
                                  <name>phs_hi_5</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">89</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 5 -- high part.
                                      Total integer phase in cycles at (time tag + 0.5 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_5</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">93</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 5 -- low part.
                                      Total integer phase in cycles at (time tag + 0.5 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_5</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">97</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 5 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.5 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_6</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">101</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 6 -- high part.
                                      Total integer phase in cycles at (time tag + 0.6 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_6</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">105</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 6 -- low part.
                                      Total integer phase in cycles at (time tag + 0.6 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_6</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 6 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.6 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_7</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">113</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 7 -- high part.
                                      Total integer phase in cycles at (time tag + 0.7 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_7</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">117</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 7 -- low part.
                                      Total integer phase in cycles at (time tag + 0.7 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_7</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">121</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 7 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.7 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_8</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">125</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 8 -- high part.
                                      Total integer phase in cycles at (time tag + 0.8 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_8</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">129</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 8 -- low part.
                                      Total integer phase in cycles at (time tag + 0.8 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_8</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">133</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 8 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.8 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_9</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">137</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 9 -- high part.
                                      Total integer phase in cycles at (time tag + 0.9 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_9</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">141</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 9 -- low part.
                                      Total integer phase in cycles at (time tag + 0.9 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_9</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">145</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 9 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.9 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_avg</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">149</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>Averaged phase sample  -- high part.  
                                      One second averaged phase, centered around time tag, then divided by 2**32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_avg</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">153</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>Averaged phase sample -- low part.
                                      One second averaged phase, centered around time tag, modulo 2**32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_avg</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">157</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>Averaged phase sample -- fractional part.
                                      One second averaged phase, centered around time tag; fractional part multiplied by 2**32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_freq</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">161</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Downlink frequency at the time tag.
                                      Values 2.2e9 to 32.3e9 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dop_resid</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">169</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Doppler residual -- negative of the frequency residual.
                                      Values -1.0e6 to 1.0e6 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dop_noise</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">173</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Doppler noise averaged over 10 points in record.
                                      Values 0.0 to 1000.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>slipped_cycles</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">177</field_location>
                                  <data_type>SignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Slipped cycles.
                                      Values -10 to 10 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_loop_type</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">181</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier loop type.
                                      Values 1 to 3 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>snt_flag</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">182</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      SNT measurement flag.
                                         0 = SNT value is the predicted value; 
                                         1 = SNT value is the measured value
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_resid_wt</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">183</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Carrier residual weight. 
                                      The weight value applied to residual phase error in carrier tracking.
                                      When the carrier is suppressed,  carrier weight is 1.0 minus this value.
                                      Values 0.0 to 1.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sup_data_id</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">187</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Support data ID.
                                      Name of the frequency predicts set used.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sup_data_rev</name>
                                  <field_number>50</field_number>
                                  <field_location unit="byte">195</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Support data revision.
                                      Revision of the frequency predicts set used.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_time_offset</name>
                                  <field_number>51</field_number>
                                  <field_location unit="byte">203</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Predicts time offset.
                                      Seconds added to current time.
                                      Values -8.64e4 to 8.64e4 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_freq_offset</name>
                                  <field_number>52</field_number>
                                  <field_location unit="byte">211</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Predicts frequency offset. 
                                      Hz added to predicted value.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_resid_tol_flag</name>
                                  <field_number>53</field_number>
                                  <field_location unit="byte">219</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier residual tolerance flag.
                                         0 = Out of tolerance; 
                                         1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>time_tag_corr_flag</name>
                                  <field_number>54</field_number>
                                  <field_location unit="byte">220</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Time tag correction flag.
                                      Indicates results of validation of the block time tag.
                                         0 = No validation attempted; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>type_time_corr_flag</name>
                                  <field_number>55</field_number>
                                  <field_location unit="byte">221</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Type of time tag correction flag.
                                      Indicates what type of time tag correction was made.
                                         0 = No correction;
                                         1 = Year correction; 
                                         2 = DOY correction; 
                                         3 = Both Year and DOY correction
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dop_mode_corr_flag</name>
                                  <field_number>56</field_number>
                                  <field_location unit="byte">222</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Doppler mode correction flag.
                                      Indicates the results of the validation of the Doppler mode.
                                         0 = Not applicable or no validation attempted; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_stn_corr_flag</name>
                                  <field_number>57</field_number>
                                  <field_location unit="byte">223</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station correction flag.
                                      Indicates the results of the validation of the uplink station.
                                         0 = Not applicable or no validation attempted; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1</name>
                                  <field_number>58</field_number>
                                  <field_location unit="byte">224</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved. One byte.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve8</name>
                                  <field_number>59</field_number>
                                  <field_location unit="byte">225</field_location>
                                  <data_type>UnsignedMSB8</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Reserved. Eight bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>Uplink Sequential Ranging Phase   (Data Type 02)</name>
                   <offset unit="byte">19260346</offset>
                   <records>28079</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">214</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 132</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>32</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 132 for uplink data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">70</group_length>
                              <Field_Binary>
                                   <name>secondary_chdo_type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Type attribute of the secondary CHDO.  The following values are possible:
                                            132 = uplink data types;
                                            133 = downlink data types;
                                            134 = derived data types;
                                            135 = interferometric data types;
                                            136 = filtered data types.
                                         Set to 132 for this Table.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>secondary_chdo_length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Length attribute of the secondary CHDO.  
                                         Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                         The following values are possible:
                                             66 = uplink data types;
                                            110 = downlink data types;
                                            124 = derived data types;
                                             88 = interferometric data types;
                                             98 = filtered data types.
                                          Set to 66 for this Table.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>orig_id</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Originator ID.
                                         Indicates where this SFDU originated. 
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>last_modifier_id</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Last modifier ID.
                                         Indicates where the contents of this SFDU were last modified. 
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve1a</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Reserved for future expansion of the next field (scft_id).
                                         A value of 0 is expected.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>scft_id</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Spacecraft number.  Values between 1 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>upl_rec_seq_num</name>
                                   <field_number>7</field_number>
                                   <field_location unit="byte">9</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <description>
                                       Uplink record sequence number (UPL RSN).
                                       This is the record sequence number reported by the uplink subsystem (UPL) equipment.
                                         Values between 0 and 2**32-1 are allowed.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>rec_seq_num</name>
                                   <field_number>8</field_number>
                                   <field_location unit="byte">13</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <description>
                                         Record sequence number (RSN).
                                         Begins with zero, then increments by one for each successive uplink tracking 
                                         SFDU of the same data type.  Wraps around from 2**32-1 to zero. Value is reset 
                                         to zero when the data processing system software is restarted.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>year</name>
                                   <field_number>9</field_number>
                                   <field_location unit="byte">17</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Time tag -- year
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>doy</name>
                                   <field_number>10</field_number>
                                   <field_location unit="byte">19</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Time tag -- day of year
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sec</name>
                                   <field_number>11</field_number>
                                   <field_location unit="byte">21</field_location>
                                   <data_type>IEEE754MSBDouble</data_type>
                                   <field_length unit="byte">8</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Time tag -- seconds of day
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rct_day</name>
                                   <field_number>12</field_number>
                                   <field_location unit="byte">29</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>day</unit>
                                   <description>
                                         Record creation time -- days since 1 January 1958.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rct_msec</name>
                                   <field_number>13</field_number>
                                   <field_location unit="byte">31</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <field_format>%10d</field_format>
                                   <unit>millisecond</unit>
                                   <description>
                                         Record creation time -- milliseconds of day
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_dss_id</name>
                                   <field_number>14</field_number>
                                   <field_location unit="byte">35</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink antenna number.  A value between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_band</name>
                                   <field_number>15</field_number>
                                   <field_location unit="byte">36</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink frequency band.
                                            0 = Unknown; 
                                            1 = S-band; 
                                            2 = X-band; 
                                            3 = Ka-band; 
                                            4 = Ku-band; 
                                            5 = L-band
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_assembly_num</name>
                                   <field_number>16</field_number>
                                   <field_location unit="byte">37</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink Assembly Number.
                                         Note that this is to allow for potential future cases where there might be more 
                                         than one uplink of the same band at the same antenna.
                                            0 = Invalid/unknown; 
                                            1 = S- or X-band uplink; 
                                            2 = Ka-band uplink
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_num</name>
                                   <field_number>17</field_number>
                                   <field_location unit="byte">38</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmitter number.  Value depends on transmitter used.  
                                         Values between 0 and 3 are allowed;  0 indicates unknown.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_stat</name>
                                   <field_number>18</field_number>
                                   <field_location unit="byte">39</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmit status.
                                            0 = Not transmitting out the horn; 
                                            1 = Transmitting out the horn; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_mode</name>
                                   <field_number>19</field_number>
                                   <field_location unit="byte">40</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmitter mode.
                                            0 = Low power; 
                                            1 = High power; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>cmd_modul_stat</name>
                                   <field_number>20</field_number>
                                   <field_location unit="byte">41</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Command modulation status.
                                            0 = OFF; 
                                            1 = ON; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rng_modul_stat</name>
                                   <field_number>21</field_number>
                                   <field_location unit="byte">42</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Ranging modulation status.
                                            0 = OFF; 
                                            1 = ON; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>fts_vld_flag</name>
                                   <field_number>22</field_number>
                                   <field_location unit="byte">43</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Frequency and Timing (FTS) validity.
                                            0 = Equipment is not synced with FTS; 
                                            1 = Equipment is synced with FTS
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_software_version</name>
                                   <field_number>23</field_number>
                                   <field_location unit="byte">44</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink Software version number.
                                         Gives the version major op code for the uplink software.
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_time_tag_delay</name>
                                   <field_number>24</field_number>
                                   <field_location unit="byte">45</field_location>
                                   <data_type>IEEE754MSBDouble</data_type>
                                   <field_length unit="byte">8</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Transmit time tag delay.
                                         Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                         Values 0.0 to 1.0 are allowed.  Value of -1.0 indicates invalid (or not provided).
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_zheight_corr</name>
                                   <field_number>25</field_number>
                                   <field_location unit="byte">53</field_location>
                                   <data_type>IEEE754MSBSingle</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Uplink Z-height correction.
                                         Values -1.0 to 1.0 are possible.  Value -99.0 indicates invalid.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>mod_day</name>
                                   <field_number>26</field_number>
                                   <field_location unit="byte">57</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Last modification time -- days since 1 January 1958.
                                         Values 0 to 2**16-1 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>mod_msec</name>
                                   <field_number>27</field_number>
                                   <field_location unit="byte">59</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <unit>milliseconds</unit>
                                   <description>
                                         Last modification time -- milliseconds of day.
                                         Values 0 to 86400999 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>version_num</name>
                                   <field_number>28</field_number>
                                   <field_location unit="byte">63</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Version number of the assembly that generated the data. 
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sub_version_num</name>
                                   <field_number>29</field_number>
                                   <field_location unit="byte">64</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Sub-version number of the assembly that generated the data.
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sub_sub_version_num</name>
                                   <field_number>30</field_number>
                                   <field_location unit="byte">65</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Sub-sub-version number of the assembly that generated the data.
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve1b</name>
                                   <field_number>31</field_number>
                                   <field_location unit="byte">66</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <field_format>%1d</field_format>
                                   <description>
                                         Reserved. One byte.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve4a</name>
                                   <field_number>32</field_number>
                                   <field_location unit="byte">67</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <field_format>%10d</field_format>
                                   <description>
                                         Reserved. Four bytes.
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Uplink Sequential Ranging Phase CHDO (Data Type 2)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>34</fields>
                              <groups>0</groups>
                              <description>Uplink Sequential Ranging Phase CHDO (Data Type 2)</description>
                              <group_location unit="byte">103</group_location>
                              <group_length unit="byte">112</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the uplink sequential ranging phase data CHDO. 
                                      Set to 10 because this CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the uplink sequential ranging phase data CHDO value field. 
                                      Number of bytes after this item.  Set to 108.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>stn_cal</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Station calibration value.  (Two-way).  
                                      Value includes the equipment in the path, but not the Z-height correction. 
                                      Values 0.0 to 1.8e5 are allowed; value 0.0 indicates not measured.
                                      One range unit (RU) = (exc_scalar_den/exc_scalar_num)/(16*FRQ_UP) where
                                      FRQ_UP is the uplink carrier frequency and the two scalars are given
                                      in fields 25 and 26.  Range is measured in RU to give a stable reference
                                      when the uplink is being ramped.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_stn_cal</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Uplink station calibration value.  For definition of range unit, see field 3.
                                      Value includes the uplink equipment in the path, but not the Z-height correction. 
                                      Values 0.0 to 1.8e5 are allowed; value 0.0 indicates not measured.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_cal_freq</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">21</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Uplink calibration frequency -- frequency at which the calibration was done.
                                      Values 2.0e9 to 34.4e9 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cal_std_dev</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Standard deviation of station calibration value.
                                      Applies to stn_cal (field 3) and ul_stn_cal (field 4).
                                      Values 0.0 to 1.8e5 are allowed.
                                      For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cal_pts</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Calibration points -- number of measurements made in computing station calibration values.
                                      Applies to stn_cal (field 3), ul_stn_cal (field 4), and cal_std_dev(field 6).
                                      Values 0 to 65535 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_rng_phs</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Measured range phase.  For definition of range unit, see field 3.
                                      Values 0.0 to 2**30 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_switch_stat</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">43</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter switch status.
                                         0 = Antenna; 
                                         1 = Water load; 
                                         2 = Invalid/unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>invert</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">44</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Inversion flag for polarity of modulation.
                                         0 = Not inverted; 
                                         1 = Inverted
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_op_pwr</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">45</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>watt</unit>
                                  <description>
                                      Transmitter output power.
                                      Values 0.0 to 500000.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>template_id</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">49</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Template ID -- ranging configuration file ID, or the name of the PN pattern.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>t1</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>second</unit>
                                  <description>
                                      T1 setting -- the length of time that the first component (the clock) is transmitted.
                                      Values 1 to 3600 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>t2</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">59</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>second</unit>
                                  <description>
                                      T2 setting -- the length of time that each subsequent component is transmitted.
                                      Values 1 to 1800 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>t3</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">61</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>second</unit>
                                  <description>
                                      T3 setting -- the length of time that the clock is transmitted for each DRVID measurement.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>first_comp_num</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">63</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      First component number.  See TRK-2-34 documentation for explanation.
                                      Values 1 to 24 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_comp_num</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">64</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last component number.  See TRK-2-34 documentation for explanation.
                                      Values 1 to 24 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chop_comp_num</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Chop component number -- the component used to chop the other components.
                                      Values 0 to 10 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>num_drvid</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">66</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Number of DRVID measurements.  Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_inphs_time_year</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">67</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Transmit In-phase time -- year.
                                      Year of the time of zero phase on uplink range generation.
                                      Values 1958 to 3000 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_inphs_time_doy</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Transmit In-phase time -- day of year.
                                      Day of year of the time of zero phase on uplink range generation.
                                      Values 1 to 366 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_inphs_time_sec</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">71</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Transmit In-phase time -- seconds of day.
                                      Seconds of day of the time of zero phase on uplink range generation.
                                      Values 0.0 to 86400.999999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_sup_rng_modul</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">79</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB</unit>
                                  <description>
                                      Carrier Suppression by ranging modulation.
                                      Reduction in carrier power due to ranging modulation.
                                      Values 0.0 to 15.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_modul_amp</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Ranging modulation amplitude.
                                      Actual digital modulation amplitude used by the ranging hardware.
                                      Values 0 to 2**12 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>exc_scalar_num</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">85</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Exciter Scalar Numerator.
                                      Numerator of ratio between ranging reference signal and uplink sky frequency.
                                      Values 1 to 2**32-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>exc_scalar_den</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">89</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Exciter Scalar Denominator.
                                      Denominator of ratio between ranging reference signal and uplink sky frequency.
                                      Values 1 to 2**32-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_cycle_time</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">93</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Ranging cycle time -- time to complete one cycle of the ranging code.
                                      Values 4.0 to 504536.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>time_tag_corr_flag</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">101</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Time tag correction flag -- indicates results of validation of the block time tag.
                                         0 = No validation attempted; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>type_time_corr_flag</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">102</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Type of time tag correction flag -- indicates  type of time tag correction  made.
                                         0 = No correction; 
                                         1 = Year correction; 
                                         2 = DOY correction; 
                                         3 = Both Year and DOY correction
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>clock_waveform</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">103</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Clock waveform type.
                                         0 = Square wave; 
                                         1 = Sine wave
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chop_start_num</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">104</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Chop Start -- the first component chopped.
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_meas_type</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">105</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Type of sequential range measurement.
                                         0 = Ranging Round Trip; 
                                         1 = Calibration; 
                                         2 = Telemetry-Based Ranging; 
                                         3 = 1-way to Spacecraft; 
                                         4 = 1-way from Spacecraft; 
                                         5 = Coupled Noncoherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fabricated_sfdu_flag</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">106</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Fabricated SFDU Flag.
                                      Indicates whether this SFDU was artificially fabricated in support of 3-way ranging.
                                         0 = Originally generated by UPL and validated by TTC software; 
                                         1 = Fabricated by TTC software 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve6</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">107</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">6</field_length>
                                  <description>
                                      Reserved. Six bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>Downlink Sequential Ranging Phase (Data Type 03)</name>
                   <offset unit="byte">25269252</offset>
                   <records>21</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">324</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 133</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>49</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 133 for downlink data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">114</group_length>
                              <Field_Binary>
                                  <name>secondary_chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the secondary CHDO.  The following values are possible:
                                         132 = uplink data types;
                                         133 = downlink data types;
                                         134 = derived data types;
                                         135 = interferometric data types;
                                         136 = filtered data types.
                                      Set to 133 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>secondary_chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the secondary CHDO.  
                                      Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                      The following values are possible:
                                          66 = uplink data types;
                                         110 = downlink data types;
                                         124 = derived data types;
                                          88 = interferometric data types;
                                          98 = filtered data types.
                                      Set to 110 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>orig_id</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Originator ID.
                                      Indicates where this SFDU originated. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_modifier_id</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last modifier ID.
                                      Indicates where the contents of this SFDU were last modified. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved for future expansion of the next field (scft_id).
                                      A value of 0 is expected.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_id</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">8</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft number.  Values between 1 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dtt_rec_seq_num</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      RDownlink record sequence number (DTT RSN) -- the number reported by
                                      the downlink subsystem (DTT) equipment.  Values between 0 and 2**32-1
                                      are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rec_seq_num</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Record sequence number (RSN).
                                      Begins with zero, then increments by one for each successive downlink tracking 
                                      SFDU of the same data type.  Wraps around from 2**32-1 to zero. Value is reset 
                                      to zero when the data processing system software is restarted.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>year</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Time tag -- year
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>doy</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">19</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Time tag -- day of year.
                                      Values between 1 and 366 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sec</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">21</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Time tag -- seconds of day.
                                      Values between 0.00 and 86400.99 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_day</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Record creation time -- days since 1 January 1958.
                                      Values between 0 and 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_msec</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Record creation time -- milliseconds of day.
                                      Values between 0 and 86400999 are allowed.
                                  </description>
                              </Field_Binary>                              
                              <Field_Binary>
                                  <name>dl_dss_id</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink antenna number.
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_band</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">36</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink frequency band.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band;
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_chan_num</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink channel number.
                                      Values between 1 and 24 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_mode</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">38</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Predicts mode -- the predicts subset used by downlink channel.
                                         0 = No Predicts; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_prdx_stn</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">39</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station used for predicts.  Valid only if prdx_mode (field 17) is 2 or 3. 
                                      Values 0 to 255 are allowed; a value 0 means that the number is unknown 
                                      or not valid (e.g., no uplink).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band_dl</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">40</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band assumed by downlink.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_delay</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">41</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Array delay value -- time delay added to path by arraying equipment.  
                                      Obtained from arraying equipment.  Any measurements include this delay.  
                                      Values 0.0 to 1.0 are allowed.  
                                      Valid only if Array Flag (array_flag is field 23) is non-zero.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fts_vld_flag</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">49</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Frequency and Timing (FTS) validity.
                                         0 = Equipment is not synced with FTS; 
                                         1 = Equipment is synced with FTS
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_lock_stat</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">50</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier lock status.
                                         0 = Off; 
                                         1 = Open (only using predicts); 
                                         2 = Acquiring, FFT Search; 
                                         3 = Acquiring, Waiting for Lock Decision; 
                                         4 = In Lock; 
                                         5 = Out of Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_flag</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Array flag.
                                         0 = Not arrayed; 
                                         1 = Arrayed with Full Spectrum Processing subsystem #1; 
                                         2 = Arrayed with Full Spectrum Processing subsystem #2
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>polarization</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">52</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Polarization.
                                         0 = RCP; 
                                         1 = LCP;
                                         2 = Unknown;
                                         3 = Not applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>diplxr_stat</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Diplexer status.
                                         0 = Low noise; 
                                         1 = Diplexed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_num</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">54</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Number.
                                      Values 0-4 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rf_if_chan_num</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      RF-to-IF Downconverter Channel number.
                                      Values 1 or 2 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>if_num</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">56</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      IF input number -- defines path into downlink channel.
                                      Values 1 to 3 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_time_tag_delay</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Receive time tag delay.  
                                      Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).
                                      Values 0.0 to 1.0 are allowed; value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_zheight_corr</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Downlink Z-height correction. 
                                      Values -1.000 to 1.000 are allowed; value -99.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_ul_stn</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated uplink station.  
                                      The uplink station per the validation process.  
                                      Values 0 to 255 are allowed; value 0 means that the antenna is unknown or not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dop_mode</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">70</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated Doppler mode.  
                                         0 = Unknown or not applicable; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_scft_coh</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">71</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated spacecraft coherency.  
                                         0 = Unknown or not applicable; 
                                         1 = Coherent; 
                                         2 = Non-coherent; 
                                         3 = Transponded, non-coherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_lock</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">72</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder lock status.
                                         0 = Unknown; 
                                         1 = Out-of-lock; 
                                         2 = In Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_num</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">73</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder number.
                                      Values 1 to 5 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_software_version</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">74</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink software version number -- the DCC software version major op code.
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_freq</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">75</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Spacecraft one-way frequency.
                                      Values 2.0e9 to 32.3e9 are allowed; value 0.0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_delay</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Spacecraft transponder delay (the coherent ranging delay).  
                                      Values 0.0 to 1.0 are allowed; value -1.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_num</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">91</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- numerator.
                                      Values 0 to 2**32-1 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_den</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">95</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- denominator.
                                      Values 0 to 2**32-1 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_twnc_stat</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">99</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft two-way non-coherent (TWNC) status.
                                         0 = Unknown;
                                         1 = OFF; 
                                         2 = ON
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_type</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">100</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft oscillator type.
                                         0 = Unknown; 
                                         1 = AUX OSC (auxiliary oscillator); 
                                         2 = USO (ultra-stable oscillator)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_day</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">101</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Last modification time -- days since 1 January 1958.
                                      Values 0 to 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_msec</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">103</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Last modification time -- milliseconds of day.
                                      Values 0 to 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>version_num</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">107</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Version number of the assembly that generated the data. 
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_version_num</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">108</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-version number of the assembly that generated the data.
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_sub_version_num</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-sub-version number of the assembly that generated the data.
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_corr_value</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">110</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Correction Value -- indicates results of validation of LNA number. 
                                      Values 1 to 4 are allowed and should be substituted for lna_num (field 26).
                                      Value 0 indicates no validation or correction was made.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve4</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">111</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Reserved. Four bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Downlink Sequential Ranging Phase CHDO (Data Type 3)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>57</fields>
                              <groups>0</groups>
                              <description>Downlink Sequential Ranging Phase CHDO (Data Type 3)</description>
                              <group_location unit="byte">147</group_location>
                              <group_length unit="byte">178</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the downlink sequential ranging phase data CHDO.
                                      Set to 10 because the CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the downlink sequential ranging phase data CHDO value field.
                                      Number of bytes after this item.  Set to 174.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>stn_cal</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Station calibration value. (Two-way).
                                      Value includes the equipment in the path, but not the Z-height correction. 
                                      Values 0.0 to 1.8e5 are allowed; value 0.0 indicates not measured.
                                      One range unit (RU) = (exc_scalar_den/exc_scalar_num)/(16*FRQ_UP) where
                                      FRQ_UP is the uplink carrier frequency and the two scalars are given
                                      in fields 36 and 37.  Range is measured in RU to give a stable reference
                                      when the uplink is being ramped.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_stn_cal</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Downlink station calibration value.  For definition of range unit, see field 3.
                                      Value includes the downlink equipment in the path, but not the Z-height correction.
                                      Values 0.0 to 1.8e5 are allowed; value 0.0 indicates not measured.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_cal_freq</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">21</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Downlink calibration frequency -- frequency at which the calibration was done.
                                      Values 2.2e9 to 32.3e9 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cal_std_dev</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Standard deviation of station calibration value.
                                      Applies to stn_cal (field 3) and dl_stn_cal (field 4).
                                      Values 0.0 to 1.8e5 are allowed.  For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cal_pts</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Calibration points -- number of measurements made in computing station calibration values.
                                      Applies to stn_cal (field 3), dl_stn_cal (field 4), and cal_std_dev(field 6).
                                      Values 0 to 65535 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_rng_phs</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Measured range phase.  Values 0 to 2**30 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>figure_merit</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">43</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>percent</unit>
                                  <description>
                                      Probability of Acquistion (formerly called  Figure of Merit).
                                      The probability of acquiring the correct range.
                                      Values 0.0 to 100.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_resid</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Range residual -- measured range minus predicted range.
                                      Values -2**30 to 2**30 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Differenced range versus integrated Dopper (DRVID), measured using phase data from carrier.
                                      Values -2**30 to 2**30 are allowed.  For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rtlt</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">63</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Round trip light time (predicted).  Values 0.0 to 86400.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pcn0</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">67</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>db*Hz</unit>
                                  <description>
                                      Pc/N0 -- ratio of carrier power to noise power spectral density.
                                      Values 0.0 to 90.0 are allowed; value -300.0 indicates no signal or carrier is suppressed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pcn0_resid</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">71</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Pc/N0 residual (actual value minus predicted value).
                                      Values -90.0 to 90.0 are allowed; value -300.0 indicates no signal or carrier is suppressed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pdn0</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">75</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>db*Hz</unit>
                                  <description>
                                      Pd/N0 -- ratio of data power to noise power spectral density. 
                                      Values 0.0 to 90.0 are allowed; value -300.0 indicates no signal.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pdn0_resid</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">79</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Pd/N0 residual (actual value minus predicted value).
                                      Values -90.0 to 90.0 are allowed; value -300.0 indicates no signal.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prn0</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Pr/N0 (ranging power to noise power spectral density). 
                                      Values -10.0 to 90.0 are allowed; value -300.0 indicates no signal.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prn0_resid</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">87</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Pr/N0 residual (actual value minus predicted value).
                                      Values -90.0 to 90.0 are allowed; value -300.0 indicates no signal.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>system_noise_temp</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">91</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>K</unit>
                                  <description>
                                      System Noise Temperature.  Values 0.1 to 2000.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_loop_type</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">95</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier loop type.
                                      Values 1 to 3 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>snt_flag</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">96</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      SNT measurement flag.
                                         0 = SNT value is the predicted value; 
                                         1 = SNT value is the measured value
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_resid_wt</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">97</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Carrier residual weight -- the value applied to residual phase error in carrier tracking.
                                      Suppressed carrier weight is 1.0 minus this value.
                                      Values 0.0 to 1.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>template_id</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">101</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Template ID -- ranging configuration file ID, or the name of the PN pattern.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>invert</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Inverted polarity flag.
                                      Inverted implies that the polarity of the correlation reference is the invert 
                                      of what was transmitted.
                                         0 = Not inverted; 
                                         1 = Inverted
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>correl_type</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">110</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Correlation type.
                                         0 = Square wave; 
                                         1 = Sine wave
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>t1</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">111</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>second</unit>
                                  <description>
                                      T1 setting -- the length of time the first component (the clock) is transmitted.
                                      Values 1 to 3600 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>t2</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">113</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>second</unit>
                                  <description>
                                      T2 setting -- the length of time that each subsequent compionent is transmitted.
                                      Values 1 to 1800 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>t3</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">115</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>second</unit>
                                  <description>
                                      T3 setting -- the length of time that the clock is transmitted for each DRVID.
                                      Values 0 to 1800 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>first_comp_num</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">117</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      First component number.  See TRK-2-34 documentation for explanation.
                                      Values 1 to 24 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_comp_num</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">118</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last component number.  See TRK-2-34 documentation for explanation.
                                      Values 1 to 24 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chop_comp_num</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">119</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Chop component number -- the component used to chop the other components.
                                      Values 0 to 10 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>num_drvid</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">120</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Number of DRVID measurements.
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_inphs_time_year</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">121</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>year</unit>
                                  <description>
                                      Receive in-phase time -- year.
                                      Year of the time of zero phase on downlink range signal correlation.
                                      Values 1958 to 3000 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_inphs_time_doy</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">123</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Receive in-phase time -- day of year.
                                      Day of year of the time of zero phase on downlink range signal correlation.
                                      Values 1 to 366 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_inphs_time_sec</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">125</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Receive in-phase time -- seconds of day.
                                      Seconds of day of the time of zero phase on downlink range signal correlation.
                                      Values 0.0 to 86400.999999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>exc_scalar_num</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">133</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Exciter Scalar Numerator.
                                      Numerator of ratio between ranging reference signal and uplink sky frequency.
                                      Values  1 to 2**32-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>exc_scalar_den</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">137</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Exciter Scalar Denominator.
                                      Denominator of ratio between ranging reference signal anduplink sky frequency.
                                      Values 1 to 2**32-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_cycle_time</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">141</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Ranging cycle time (to complete one cycle of the ranging code).
                                      Values 4.0 to 504536.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>inphs_correl</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">149</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      In-phase correlation value of the clock component correlation. 
                                      Values -1.0e8 to 1.0e8 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>quad_phs_correl</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">153</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Quadrature phase correlation value of the clock component correlation.
                                      Values -1.0e8 to 1.0e8 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>metrics_vld_flag</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">157</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Metrics validity flag -- validity of the Range Residual (rng_resid, field 10) and
                                      DRVID (drvid, field 11) measurements.
                                         0 = Invalid (No uplink data available); 
                                         1 = Invalid (Other reasons); 
                                         2 = Valid
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>correl_vld_flag</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">158</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Correlation validity flag.
                                         0 = Invalid; 
                                         1 = Valid
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_resid_tol_flag</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">159</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Range residual tolerance flag.
                                         0 = Out of  tolerance; 
                                         1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid_tol_flag</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">160</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      DRVID tolerance flag.
                                         0 = Out of  tolerance; 
                                         1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prn0_resid_tol_flag</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">161</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Pr/N0 residual tolerance flag.
                                         0 = Out of  tolerance; 
                                         1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_sigma_tol_flag</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">162</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Range sigma tolerance flag.
                                         0 = Out of  tolerance; 
                                         1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_vld_flag</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">163</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Range validity flag.
                                         0 = Invalid; 
                                         1 = Valid
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_config_flag</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">164</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Range configuration change flag.
                                         0 = Changed; 
                                         1 = Unchanged
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_hw_flag</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">165</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Ranging hardware status flag.
                                         0 = Bad; 
                                         1 = Good
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>time_tag_corr_flag</name>
                                  <field_number>50</field_number>
                                  <field_location unit="byte">166</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Time tag correction flag -- indicates results of validation of the block time tag.
                                         0 = No validation attempted; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>type_time_corr_flag</name>
                                  <field_number>51</field_number>
                                  <field_location unit="byte">167</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Type of time tag correction flag -- indicates what type of time tag correction was made.
                                         0 = No correction; 
                                         1 = Year correction; 
                                         2 = DOY correction; 
                                         3 = Both Year and DOY correction
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dop_mode_corr_flag</name>
                                  <field_number>52</field_number>
                                  <field_location unit="byte">168</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Doppler mode correction flag -- indicates the results of the validation of the doppler mode..
                                         0 = Not applicable or no validation attempted; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_stn_corr_flag</name>
                                  <field_number>53</field_number>
                                  <field_location unit="byte">169</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station correction flag -- indicates the results of the validation of the uplink station.
                                         0 = Not applicable or no validation attempted; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chop_start_num</name>
                                  <field_number>54</field_number>
                                  <field_location unit="byte">170</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      The first component chopped.  Values 0 to 25 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_meas_type</name>
                                  <field_number>55</field_number>
                                  <field_location unit="byte">171</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Type of sequential range measurement.
                                         0 = Ranging  Round Trip; 
                                         1 = Calibration; 
                                         2 = Telemetry-Based Ranging; 
                                         3 = 1-way to Spacecraft; 
                                         4 = 1-way from Spacecraft; 
                                         5 = Coupled Noncoherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>stn_cal_corr_flag</name>
                                  <field_number>56</field_number>
                                  <field_location unit="byte">172</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Station calibration correction flag -- indicates result of validation of station calibration values.
                                         0 = Unable to correct; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed ul_stn_cal; 
                                         3 = Validated, changed dl_stn_cal; 
                                         4 = Validated, changed both ul_stn_cal and dl_stn_cal; 
                                         5 = Validated, changed round-trip stn_cal
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve6</name>
                                  <field_number>57</field_number>
                                  <field_location unit="byte">173</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">6</field_length>
                                  <description>
                                      Reserved. Six bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>Sequential Ranging                (Data Type 07)</name>
                   <offset unit="byte">25276056</offset>
                   <records>21</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">350</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 134</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>55</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 134 for derived data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">128</group_length>
                              <Field_Binary>
                                  <name>secondary_chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the secondary CHDO.  The following values are possible:
                                         132 = uplink data types;
                                         133 = downlink data types;
                                         134 = derived data types;
                                         135 = interferometric data types;
                                         136 = filtered data types.
                                      Set to 134 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>secondary_chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the secondary CHDO.  
                                      Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                      The following values are possible:
                                          66 = uplink data types;
                                         110 = downlink data types;
                                         124 = derived data types;
                                          88 = interferometric data types;
                                          98 = filtered data types.
                                      Set to 124 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>orig_id</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Originator ID. 
                                      Indicates where this SFDU originated. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_modifier_id</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last modifier ID. 
                                      Indicates where the contents of this SFDU were last modified. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved for future expansion of the next field (scft_id).
                                      A value of 0 is expected.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_id</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">8</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft number.  Values between 1 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rec_seq_num</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Record sequence number (RSN).
                                      Begins with zero; increments by one for each successive tracking 
                                      SFDU of the same data type; wraps around from 2**32-1 to zero. 
                                      Value is reset to zero when the data processing system software is restarted.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>year</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Time tag -- year
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>doy</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">15</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Time tag -- day of year.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sec</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Time tag -- seconds of day.
                                      Values 0.00 to 86400.99 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_day</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Record creation time -- days since 1 January 1958.
                                      Values between 0  and 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_msec</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">27</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Record creation time -- milliseconds of day.
                                      Values between 0 and 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>stn_stream_src</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Station stream source. 
                                         1 = UPL/DTT;
                                         2 = non-UPL-DTT: TRK-2-30; 
                                         3 = non-UPL-DTT: TRK-2-20
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">32</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band. 
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_assembly_num</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink Assembly Number.
                                      Note that this is to allow for potential future cases where there 
                                      might be more than one uplink of the same band at the same antenna.
                                         0 = Unknown or not applicable; 
                                         1 = S- or X-band uplink; 
                                         2 = Ka-band uplink
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_num</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">34</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter number. 
                                      Values 1-3 depend on the transmitter used. 
                                      A value of 0 means that the number is unknown or not applicable.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_status</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmit Status.
                                         0 = Not transmitting out the horn; 
                                         1 = Transmitting out the horn; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_mode</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">36</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter mode.
                                         0 = Low power; 
                                         1 = High power; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cmd_modul_stat</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Command modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_modul_stat</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">38</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Ranging modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_time_tag_delay</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">39</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Transmit time tag delay.
                                      Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values between 0.0 and 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_zheight_corr</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Uplink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_dss_id</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink antenna number.
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">52</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved. One byte.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_chan_num</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink channel number.
                                      Values 0 to 24 are allowed; value of 0 implies unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_mode</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">54</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Predicts mode.
                                      Predicts subset used by downlink channel.
                                         0 = No Predicts; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way; 
                                         4 = Unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_prdx_stn</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station used for predicts. Valid only if prdx_mode is 2 or 3 (field 26).
                                      Values 0 to 255 are allowed; a value 0 means that the number is unknown 
                                      or not valid (e.g., no uplink).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band_dl</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">56</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band assumed by downlink.
                                      Uplink band value used by downlink for turn around computations.
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_delay</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Array delay value -- time delay added to path by arraying equipment.  
                                      Obtained from arraying equipment.  Any measurements include this delay.  
                                      Valid only if Array Flag  (array_flag in field 32) is non-zero.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fts_vld_flag</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Frequency and Timing (FTS) validity.
                                        0 = Equipment is not synced with FTS; 
                                        1 = Equipment is synced with FTS
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_lock_stat</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">66</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier lock status.
                                         0 = Off; 
                                         1 = Open (using only predicts); 
                                         2 = Acquiring, FFT Search; 
                                         3 = Acquiring, Waiting for Lock Decision; 
                                         4 = In Lock; 
                                         5 = Out of Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_flag</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">67</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Array flag.
                                         0 = Non-arrayed; 
                                         1 = Arrayed with Full Spectrum Processing subsystem #1; 
                                         2 = Arrayed with Full Spectrum Processing subsystem #2
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_num</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">68</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Number.  
                                      Values 1 to 4 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_time_tag_delay</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Receive time tag delay.  
                                      Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_zheight_corr</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">77</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Downlink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid. 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_ul_stn</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">81</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated uplink station.  
                                      The uplink station per the validation process.  
                                      Values 0 to 255 are allowed; a value 0 means that the antenna is unknown or not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dop_mode</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">82</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated Doppler mode.  
                                         0 = Unknown or not applicable; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_scft_coh</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated spacecraft coherency.  
                                         0 = Unknown or not applicable; 
                                         1 = Coherent; 
                                         2 = Non-coherent; 
                                         3 = Transponded, non-coherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dl_band</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">84</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated downlink frequency band.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band; 
                                         6 = S or X band (26m stations)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_lock</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">85</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder lock status.
                                         0 = Unknown; 
                                         1 = Out-of-lock; 
                                         2 = In Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_num</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">86</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder number.  
                                      Values 0 to 5 are allowed; value 0 indicates the transponder number is unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve2</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">87</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Reserved. Two bytes.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_freq</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">89</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Spacecraft one-way frequency.  
                                      Values 2.0e9 to 32.3e9 are allowed; set to 0.0 if unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_delay</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">97</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Spacecraft transponder delay (coherent ranging delay).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_num</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">105</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- numerator.
                                      Values 0 to 2**32-1 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_den</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- denominator.
                                      Values 0 to 2**32-1 are allowed; a value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_twnc_stat</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">113</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft two-way non-coherent (TWNC) status.
                                         0 = Unknown; 
                                         1 = OFF; 
                                         2 = ON
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_type</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">114</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft oscillator type.
                                         0 = Unknown; 
                                         1 = AUX OSC (auxiliary oscillator); 
                                         2 = USO (ultra-stable oscillator)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_day</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">115</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Last modification time -- days since 1 January 1958.  
                                      Values 0 to 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_msec</name>
                                  <field_number>50</field_number>
                                  <field_location unit="byte">117</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Last modification time -- milliseconds of day.
                                      Values 0 to 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cnt_time</name>
                                  <field_number>51</field_number>
                                  <field_location unit="byte">121</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Integration time of the counts.  
                                      Values 0.0 to 3600.0 are allowed.  A value  0 indicates Not Applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>version_num</name>
                                  <field_number>52</field_number>
                                  <field_location unit="byte">125</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Version number of the assembly that generated the data. 
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_version_num</name>
                                  <field_number>53</field_number>
                                  <field_location unit="byte">126</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-version number of the assembly that generated the data.  
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_sub_version_num</name>
                                  <field_number>54</field_number>
                                  <field_location unit="byte">127</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-sub-version number of the assembly that generated the data.  
                                      Value 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_corr_value</name>
                                  <field_number>55</field_number>
                                  <field_location unit="byte">128</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Correction Value -- indicates results of validation of LNA number.
                                      A value 1 to 4 should be used insterad of lna_num (field 33); a value 0 
                                      indicates no validation or correction was made.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Sequential Range CHDO (Data Type 7)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>56</fields>
                              <groups>0</groups>
                              <description>Sequential Range CHDO (Data Type 7)</description>
                              <group_location unit="byte">161</group_location>
                              <group_length unit="byte">190</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the sequential range data CHDO.
                                      Set to 10 because the CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the sequential range data CHDO value field. 
                                      Number of bytes after this item.  Set to 186.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_stn_cal</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Uplink station calibration value.
                                      Values 0.0 to 1.8e5 are allowed; value -1.0 indicates invalid.
                                      One range unit (RU) = (exc_scalar_den/exc_scalar_num)/(16*FRQ_UP) where
                                      FRQ_UP is the uplink carrier frequency and the two scalars are given
                                      in fields 27 and 28.  Range is measured in RU to give a stable reference
                                      when the uplink is being ramped.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_stn_cal</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Downlink station calibration value.
                                      Values 0.0 to 1.8e5 are allowed; value -1.0 indicates invalid.
                                      For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>meas_rng</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">21</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Measured range value, modulo rng_modulo (field 30).  
                                      Does not include compensation for station calibration and other adjustments.  
                                      Values 0.0 to 2**30 are allowed.  Invalid is indicated by value of -1.0.
                                      For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_obs</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Range observable modulo rng_modulo (field 30).  Includes all measurement adjustments
                                      (station calibration, time tag adjustments, spacecraft delay, and Z-height).
                                      Values 0.0 to 2**30 are allowed.  Invalid is indicated by value of -1.0.
                                      For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_obs_dl</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Downlink range observable modulo rng_modulo (field 30).  Includes all measurement adjustments 
                                      (station calibration, time tag adjustments, spacecraft delay, and Z-height).  
                                      Values 0.0 to 2**30 are allowed; value -1.0 indicates invalid.
                                      For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>clock_waveform</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">45</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink clock waveform type.
                                         0 = Square wave; 
                                         1 = Sine wave
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chop_start_num</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">46</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Chop Start -- the first component chopped. 
                                      Values 0 to 25 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>figure_merit</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>percent</unit>
                                  <description>
                                      Probability of Acquistion (formerly called  Figure of Merit).
                                      The probability of acquiring the correct range.
                                      Values 0.0 to 100.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Differenced range versus integrated Dopper (DRVID), measured using phase data from carrier.
                                      Values -2**30 to 2**30 are allowed.  For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rtlt</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">59</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Round trip light time (predicted value).
                                      Values 0.0 to 86400.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prn0</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">63</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Ratio of ranging power (Pr) to noise power spectral density (N0).
                                      Values -10.0 to 90.0 are allowed; value -300.0 indicates no signal.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_pwr</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">67</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>watt</unit>
                                  <description>
                                      Transmitter power.  Values 0.0 to 500000.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>invert</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">71</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Inverted polarity flag.  Inverted implies that the polarity of the correlation 
                                      reference is the invert of what was transmitted.
                                         0 = Not inverted; 
                                         1 = Inverted
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>correl_type</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">72</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Correlation type.
                                         0 = Square wave; 
                                         1 = Sinewave
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>t1</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">73</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>second</unit>
                                  <description>
                                      T1 setting -- the length of time the first component (the clock) is transmitted.
                                      Values 1 to 3600 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>t2</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">75</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>second</unit>
                                  <description>
                                      T2 setting -- the length of time that each subsequent compionent is transmitted.
                                      Values 1 to 1800 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>t3</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">77</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>second</unit>
                                  <description>
                                      T3 setting -- the length of time that the clock is transmitted for each DRVID.
                                      Values 0 to 1800 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>first_comp_num</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">79</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      First component number.  See TRK-2-34 documentation for explanation.
                                      Values 1 to 24 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_comp_num</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">80</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last component number.  See TRK-2-34 documentation for explanation.
                                      Values 1 to 24 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chop_comp_num</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">81</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Chop component number -- the component used to chop the other components.
                                      Values 0 to 10 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>num_drvid</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">82</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Number of DRVID measurements. 
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_inphs _time</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Transmit in-phase time-- offset from time tag of time of zero phase on uplink range signal generation.
                                      Values -86400.0 to 86400.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_inphs_time</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">87</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Receive in-phase time -- offset from time tag of time of zero phase on downlink range signal correlation.
                                      Values -86400.0 to 86400.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_sup_rng_modul</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">91</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB</unit>
                                  <description>
                                      Carrier suppression by ranging modulation -- amount carrier power is reduced by ranging modulation.
                                      Values 0.0 to 15.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>exc_scalar_num</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">95</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Exciter Scalar Numerator -- numerator of ratio between ranging reference signal and uplink sky frequency.
                                      Values 1 to 2**32-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>exc_scalar_den</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">99</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Exciter Scalar Denominator -- denominator of ratio between ranging reference signal and uplink sky frequency.
                                      Values 1 to 2**32-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_cycle_time</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">103</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Range cycle time. Time of one complete cycle of the ranging signal.
                                      Values 4.0 to 504536.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_modulo</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">111</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Range measurement modulo (ambiguity) value.
                                      Values 1 to 2**30 are allowed.
                                      For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>inphs_correl</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">115</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      The in-phase value of the clock component correlation. 
                                      Values -1.0e8 to 1.0e8 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>quad_phs_correl</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">119</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      The quadrature-phase value of the clock component correlation. 
                                      Values -1.0e8 to 1.0e8 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_freq</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">123</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Uplink frequency at time tag. 
                                      Values 2.0e9 to 34.4e9 are allowed; value 0.0 indicates unavailable.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_type</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">131</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Type of sequential range measurement.
                                         0 = Ranging  Round Trip; 
                                         1 = Calibration; 
                                         2 = Telemetry-Based Ranging; 
                                         3 = 1-way to Spacecraft; 
                                         4 = 1-way from Spacecraft; 
                                         5 = Coupled Noncoherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fabricated_ul_flag</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">132</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Fabricated uplink flag -- indicates whether this SFDU was created based on uplink records fabricated in support of 3-way ranging.
                                         0 = SFDU created using uplink records originally generated by UPL and validated by TTC software; 
                                         1 = SFDU created using uplink records fabricated by TTC software
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_noise</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">133</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Range noise.  Values 0.0 to 2**30 are allowed; value -1.0 indicates invalid.
                                      For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_prefit_resid</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">137</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Range pre-fit residual -- observed range minus predicted range.
                                      Values -2**30 to 2**30 are allowed.  For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_dl_prefit_resid</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">145</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Downlink range pre-fit residual -- observed range minus predicted range.
                                      Values -2**30 to 2**30 are allowed.  For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_prefit_resid_vld_flag</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">153</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Range pre-fit residual validity indicator.
                                         0 = Invalid pre-fit residual data; 
                                         1 = Valid pre-fit residual data
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_dl_prefit_resid_vld_flag</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">154</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink range pre-fit residual validity indicator.
                                         0 = Invalid pre-fit residual data; 
                                         1 = Valid pre-fit residual data
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_resid_tol_value</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">155</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Range residual tolerance value -- value used for setting Range residual tolerance flag.  
                                      Provided by customer.  Applies to both rng_prefit_resid (field 37) and 
                                      rng_dl_prefit_resid (field 38).  Not applicable if rng_prefit_resid_vld_flag (field 39)
                                      and rng_dl_prefit_resid_vld_flag (field 40) are 0.  Values -2**30 to 2**30 are allowed.
                                      For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid_tol_value</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">159</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      DRVID tolerance value -- value used for setting DRVID tolerance flag. Provided by customer.
                                      Values -2**30 to 2**30 are allowed.  For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prn0_resid_tol_value</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">163</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Pr/N0 residual tolerance value -- value used for setting Pr/N0 residual tolerance flag.  
                                      Provided by customer.  Values -10.0 to 90.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_sigma_tol_value</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">167</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      Range sigma tolerance value -- value used for setting Range sigma tolerance flag.  
                                      Provided by customer.  Values 0.0 to 2**30 are allowed; value -1.0 indicates not applicable.
                                      For definition of range unit, see field 3.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fom_tol_value</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">171</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>percent</unit>
                                  <description>
                                      Probability of Acquisition tolerance value -- value used in setting of Range Validity flag.
                                      Provided by customer.  Valiues 0.0 to 100.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_resid_tol_flag</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">175</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Range residual tolerance flag.
                                      Not applicable if rng_prefit_resid_vld_flag (field 39) and rng_dl_prefit_resid_vld_flag (field 40) are 0.
                                         0 = Out of  tolerance; 
                                         1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid_tol_flag</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">176</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      DRVID tolerance flag.; 
                                         0 = Out of  tolerance; 
                                         1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prn0_resid_tol_flag</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">177</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Pr/N0 residual tolerance flag.
                                         0 = Out of  tolerance; 
                                         1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_sigma_tol_flag</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">178</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Range sigma tolerance flag.
                                      Not applicable if rng_noise (field 36) is set to -1.0.
                                         0 = Out of  tolerance; 
                                         1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_vld_flag</name>
                                  <field_number>50</field_number>
                                  <field_location unit="byte">179</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Range validity flag.
                                         0 = Invalid; 
                                         1 = Valid
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_config_flag</name>
                                  <field_number>51</field_number>
                                  <field_location unit="byte">180</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Range configuration change flag.
                                         0 = Changed; 
                                         1 = Unchanged
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>stn_cal_corr_flag</name>
                                  <field_number>52</field_number>
                                  <field_location unit="byte">181</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Station calibration correction flag.
                                      Indicates results of validation of the station calibration value.
                                         0 = Unable to correct; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed uplink; 
                                         3 = Validated, changed downlink; 
                                         4 = Validated, changed both uplink and downlink
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_chan_num</name>
                                  <field_number>53</field_number>
                                  <field_location unit="byte">182</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Ranging channel number (only provided by 26m antennas).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>time_tag_corr_flag</name>
                                  <field_number>54</field_number>
                                  <field_location unit="byte">183</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Time tag correction flag -- indicates the results of validation of the block time tag.
                                         0 = No validation attempted; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>type_time_corr_flag</name>
                                  <field_number>55</field_number>
                                  <field_location unit="byte">184</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Type of time tag correction flag -- indicates what type of time tag correction was made.
                                         0 = No correction; 
                                         1 = Year correction; 
                                         2 = DOY correction; 
                                         3 = Both Year and DOY correction
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve6</name>
                                  <field_number>56</field_number>
                                  <field_location unit="byte">185</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">6</field_length>
                                  <description>
                                      Reserved. Six bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>Ramps                             (Data Type 09)</name>
                   <offset unit="byte">25283406</offset>
                   <records>48</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">144</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 132</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>32</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 132 for uplink data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">70</group_length>
                              <Field_Binary>
                                   <name>secondary_chdo_type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Type attribute of the secondary CHDO.  The following values are possible:
                                            132 = uplink data types;
                                            133 = downlink data types;
                                            134 = derived data types;
                                            135 = interferometric data types;
                                            136 = filtered data types.
                                         Set to 132 for this Table.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>secondary_chdo_length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Length attribute of the secondary CHDO.  
                                         Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                         The following values are possible:
                                             66 = uplink data types;
                                            110 = downlink data types;
                                            124 = derived data types;
                                             88 = interferometric data types;
                                             98 = filtered data types.
                                          Set to 66 for this Table.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>orig_id</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Originator ID.
                                         Indicates where this SFDU originated. 
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>last_modifier_id</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Last modifier ID.
                                         Indicates where the contents of this SFDU were last modified. 
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve1a</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Reserved for future expansion of the next field (scft_id).
                                         A value of 0 is expected.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>scft_id</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Spacecraft number.  Values between 1 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>upl_rec_seq_num</name>
                                   <field_number>7</field_number>
                                   <field_location unit="byte">9</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <description>
                                       Uplink record sequence number (UPL RSN).
                                       This is the record sequence number reported by the uplink subsystem (UPL) equipment.
                                         Values between 0 and 2**32-1 are allowed.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>rec_seq_num</name>
                                   <field_number>8</field_number>
                                   <field_location unit="byte">13</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <description>
                                         Record sequence number (RSN).
                                         Begins with zero, then increments by one for each successive uplink tracking 
                                         SFDU of the same data type.  Wraps around from 2**32-1 to zero. Value is reset 
                                         to zero when the data processing system software is restarted.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>year</name>
                                   <field_number>9</field_number>
                                   <field_location unit="byte">17</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Time tag -- year
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>doy</name>
                                   <field_number>10</field_number>
                                   <field_location unit="byte">19</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Time tag -- day of year
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sec</name>
                                   <field_number>11</field_number>
                                   <field_location unit="byte">21</field_location>
                                   <data_type>IEEE754MSBDouble</data_type>
                                   <field_length unit="byte">8</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Time tag -- seconds of day
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rct_day</name>
                                   <field_number>12</field_number>
                                   <field_location unit="byte">29</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>day</unit>
                                   <description>
                                         Record creation time -- days since 1 January 1958.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rct_msec</name>
                                   <field_number>13</field_number>
                                   <field_location unit="byte">31</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <field_format>%10d</field_format>
                                   <unit>millisecond</unit>
                                   <description>
                                         Record creation time -- milliseconds of day
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_dss_id</name>
                                   <field_number>14</field_number>
                                   <field_location unit="byte">35</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink antenna number.  A value between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_band</name>
                                   <field_number>15</field_number>
                                   <field_location unit="byte">36</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink frequency band.
                                            0 = Unknown; 
                                            1 = S-band; 
                                            2 = X-band; 
                                            3 = Ka-band; 
                                            4 = Ku-band; 
                                            5 = L-band
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_assembly_num</name>
                                   <field_number>16</field_number>
                                   <field_location unit="byte">37</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink Assembly Number.
                                         Note that this is to allow for potential future cases where there might be more 
                                         than one uplink of the same band at the same antenna.
                                            0 = Invalid/unknown; 
                                            1 = S- or X-band uplink; 
                                            2 = Ka-band uplink
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_num</name>
                                   <field_number>17</field_number>
                                   <field_location unit="byte">38</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmitter number.  Value depends on transmitter used.  
                                         Values between 0 and 3 are allowed;  0 indicates unknown.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_stat</name>
                                   <field_number>18</field_number>
                                   <field_location unit="byte">39</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmit status.
                                            0 = Not transmitting out the horn; 
                                            1 = Transmitting out the horn; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_mode</name>
                                   <field_number>19</field_number>
                                   <field_location unit="byte">40</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmitter mode.
                                            0 = Low power; 
                                            1 = High power; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>cmd_modul_stat</name>
                                   <field_number>20</field_number>
                                   <field_location unit="byte">41</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Command modulation status.
                                            0 = OFF; 
                                            1 = ON; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rng_modul_stat</name>
                                   <field_number>21</field_number>
                                   <field_location unit="byte">42</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Ranging modulation status.
                                            0 = OFF; 
                                            1 = ON; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>fts_vld_flag</name>
                                   <field_number>22</field_number>
                                   <field_location unit="byte">43</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Frequency and Timing (FTS) validity.
                                            0 = Equipment is not synced with FTS; 
                                            1 = Equipment is synced with FTS
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_software_version</name>
                                   <field_number>23</field_number>
                                   <field_location unit="byte">44</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink Software version number.
                                         Gives the version major op code for the uplink software.
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_time_tag_delay</name>
                                   <field_number>24</field_number>
                                   <field_location unit="byte">45</field_location>
                                   <data_type>IEEE754MSBDouble</data_type>
                                   <field_length unit="byte">8</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Transmit time tag delay.
                                         Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                         Values 0.0 to 1.0 are allowed.  Value of -1.0 indicates invalid (or not provided).
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_zheight_corr</name>
                                   <field_number>25</field_number>
                                   <field_location unit="byte">53</field_location>
                                   <data_type>IEEE754MSBSingle</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Uplink Z-height correction.
                                         Values -1.0 to 1.0 are possible.  Value -99.0 indicates invalid.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>mod_day</name>
                                   <field_number>26</field_number>
                                   <field_location unit="byte">57</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Last modification time -- days since 1 January 1958.
                                         Values 0 to 2**16-1 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>mod_msec</name>
                                   <field_number>27</field_number>
                                   <field_location unit="byte">59</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <unit>milliseconds</unit>
                                   <description>
                                         Last modification time -- milliseconds of day.
                                         Values 0 to 86400999 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>version_num</name>
                                   <field_number>28</field_number>
                                   <field_location unit="byte">63</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Version number of the assembly that generated the data. 
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sub_version_num</name>
                                   <field_number>29</field_number>
                                   <field_location unit="byte">64</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Sub-version number of the assembly that generated the data.
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sub_sub_version_num</name>
                                   <field_number>30</field_number>
                                   <field_location unit="byte">65</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Sub-sub-version number of the assembly that generated the data.
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve1b</name>
                                   <field_number>31</field_number>
                                   <field_location unit="byte">66</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <field_format>%1d</field_format>
                                   <description>
                                         Reserved. One byte.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve4a</name>
                                   <field_number>32</field_number>
                                   <field_location unit="byte">67</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <field_format>%10d</field_format>
                                   <description>
                                         Reserved. Four bytes.
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Ramp CHDO (Data Type 9)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>10</fields>
                              <groups>0</groups>
                              <description>Ramp CHDO (Data Type 9)</description>
                              <group_location unit="byte">103</group_location>
                              <group_length unit="byte">42</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the ramp data CHDO.
                                      Set to 10 because CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the ramp data CHDO value field. 
                                      Number of bytes after this item.  Set to 38.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_hi_phs_cycles</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Uplink phase at time tag -- high part.
                                      Total integer phase cycles divided by 2**32.
                                      Values from 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_lo_phs_cycles</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Uplink phase at time tag -- low part.
                                      Total integer phase cycles modulo 2**32.
                                      Values from 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_frac_phs_cycles</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Uplink phase at time tag -- fractional part.
                                      Fractional phase cycles multiplied by 2**32.
                                      Values from 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ramp_freq</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Uplink frequency at the time tag.
                                      Values between 2.0e9 and 34.7e9 are allowed; value 0.0 indicates unknown or invalid.
                                      Precision varies with band (phase data give higher precision): 
                                         S-band = 0.5 microhertz; 
                                         X-band = 1.6 microhertz; 
                                         Ka-band = 7.7 microhertz
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ramp_rate</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz/second</unit>
                                  <description>
                                      Rate of change of uplink frequency.
                                      Values -3.2e5 to 3.2e5 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ramp_type</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Ramp type.
                                         0 = Snap; 
                                         1 = Start of new ramp; 
                                         2 = Medial report; 
                                         3 = Periodic report; 
                                         4 = End of ramps; 
                                         5 = Ramping terminated by operator; 
                                         6 = Invalid/unknown; 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fabricated_sfdu_flag</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">34</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Fabricated SFDU Flag -- indicates whether this SFDU was artificially 
                                      fabricated in support of 3-way ranging.
                                         0 = Originally generated by UPL and validated by TTC software; 
                                         1 = Fabricated by TTC software
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve8</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedMSB8</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Reserved. Eight bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>DRVID                             (Data Type 11)</name>
                   <offset unit="byte">25290318</offset>
                   <records>21</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">202</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 134</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>55</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 134 for derived data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">128</group_length>
                              <Field_Binary>
                                  <name>secondary_chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the secondary CHDO.  The following values are possible:
                                         132 = uplink data types;
                                         133 = downlink data types;
                                         134 = derived data types;
                                         135 = interferometric data types;
                                         136 = filtered data types.
                                      Set to 134 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>secondary_chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the secondary CHDO.  
                                      Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                      The following values are possible:
                                          66 = uplink data types;
                                         110 = downlink data types;
                                         124 = derived data types;
                                          88 = interferometric data types;
                                          98 = filtered data types.
                                      Set to 124 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>orig_id</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Originator ID. 
                                      Indicates where this SFDU originated. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_modifier_id</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last modifier ID. 
                                      Indicates where the contents of this SFDU were last modified. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved for future expansion of the next field (scft_id).
                                      A value of 0 is expected.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_id</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">8</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft number.  Values between 1 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rec_seq_num</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Record sequence number (RSN).
                                      Begins with zero; increments by one for each successive tracking 
                                      SFDU of the same data type; wraps around from 2**32-1 to zero. 
                                      Value is reset to zero when the data processing system software is restarted.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>year</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Time tag -- year
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>doy</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">15</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Time tag -- day of year.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sec</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Time tag -- seconds of day.
                                      Values 0.00 to 86400.99 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_day</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Record creation time -- days since 1 January 1958.
                                      Values between 0  and 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_msec</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">27</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Record creation time -- milliseconds of day.
                                      Values between 0 and 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>stn_stream_src</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Station stream source. 
                                         1 = UPL/DTT;
                                         2 = non-UPL-DTT: TRK-2-30; 
                                         3 = non-UPL-DTT: TRK-2-20
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">32</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band. 
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_assembly_num</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink Assembly Number.
                                      Note that this is to allow for potential future cases where there 
                                      might be more than one uplink of the same band at the same antenna.
                                         0 = Unknown or not applicable; 
                                         1 = S- or X-band uplink; 
                                         2 = Ka-band uplink
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_num</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">34</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter number. 
                                      Values 1-3 depend on the transmitter used. 
                                      A value of 0 means that the number is unknown or not applicable.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_status</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmit Status.
                                         0 = Not transmitting out the horn; 
                                         1 = Transmitting out the horn; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_mode</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">36</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter mode.
                                         0 = Low power; 
                                         1 = High power; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cmd_modul_stat</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Command modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_modul_stat</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">38</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Ranging modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_time_tag_delay</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">39</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Transmit time tag delay.
                                      Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values between 0.0 and 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_zheight_corr</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Uplink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_dss_id</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink antenna number.
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">52</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved. One byte.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_chan_num</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink channel number.
                                      Values 0 to 24 are allowed; value of 0 implies unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_mode</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">54</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Predicts mode.
                                      Predicts subset used by downlink channel.
                                         0 = No Predicts; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way; 
                                         4 = Unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_prdx_stn</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station used for predicts. Valid only if prdx_mode is 2 or 3 (field 26).
                                      Values 0 to 255 are allowed; a value 0 means that the number is unknown 
                                      or not valid (e.g., no uplink).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band_dl</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">56</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band assumed by downlink.
                                      Uplink band value used by downlink for turn around computations.
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_delay</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Array delay value -- time delay added to path by arraying equipment.  
                                      Obtained from arraying equipment.  Any measurements include this delay.  
                                      Valid only if Array Flag  (array_flag in field 32) is non-zero.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fts_vld_flag</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Frequency and Timing (FTS) validity.
                                        0 = Equipment is not synced with FTS; 
                                        1 = Equipment is synced with FTS
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_lock_stat</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">66</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier lock status.
                                         0 = Off; 
                                         1 = Open (using only predicts); 
                                         2 = Acquiring, FFT Search; 
                                         3 = Acquiring, Waiting for Lock Decision; 
                                         4 = In Lock; 
                                         5 = Out of Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_flag</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">67</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Array flag.
                                         0 = Non-arrayed; 
                                         1 = Arrayed with Full Spectrum Processing subsystem #1; 
                                         2 = Arrayed with Full Spectrum Processing subsystem #2
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_num</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">68</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Number.  
                                      Values 1 to 4 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_time_tag_delay</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Receive time tag delay.  
                                      Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_zheight_corr</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">77</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Downlink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid. 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_ul_stn</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">81</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated uplink station.  
                                      The uplink station per the validation process.  
                                      Values 0 to 255 are allowed; a value 0 means that the antenna is unknown or not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dop_mode</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">82</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated Doppler mode.  
                                         0 = Unknown or not applicable; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_scft_coh</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated spacecraft coherency.  
                                         0 = Unknown or not applicable; 
                                         1 = Coherent; 
                                         2 = Non-coherent; 
                                         3 = Transponded, non-coherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dl_band</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">84</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated downlink frequency band.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band; 
                                         6 = S or X band (26m stations)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_lock</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">85</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder lock status.
                                         0 = Unknown; 
                                         1 = Out-of-lock; 
                                         2 = In Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_num</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">86</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder number.  
                                      Values 0 to 5 are allowed; value 0 indicates the transponder number is unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve2</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">87</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Reserved. Two bytes.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_freq</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">89</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Spacecraft one-way frequency.  
                                      Values 2.0e9 to 32.3e9 are allowed; set to 0.0 if unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_delay</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">97</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Spacecraft transponder delay (coherent ranging delay).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_num</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">105</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- numerator.
                                      Values 0 to 2**32-1 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_den</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- denominator.
                                      Values 0 to 2**32-1 are allowed; a value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_twnc_stat</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">113</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft two-way non-coherent (TWNC) status.
                                         0 = Unknown; 
                                         1 = OFF; 
                                         2 = ON
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_type</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">114</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft oscillator type.
                                         0 = Unknown; 
                                         1 = AUX OSC (auxiliary oscillator); 
                                         2 = USO (ultra-stable oscillator)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_day</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">115</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Last modification time -- days since 1 January 1958.  
                                      Values 0 to 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_msec</name>
                                  <field_number>50</field_number>
                                  <field_location unit="byte">117</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Last modification time -- milliseconds of day.
                                      Values 0 to 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cnt_time</name>
                                  <field_number>51</field_number>
                                  <field_location unit="byte">121</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Integration time of the counts.  
                                      Values 0.0 to 3600.0 are allowed.  A value  0 indicates Not Applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>version_num</name>
                                  <field_number>52</field_number>
                                  <field_location unit="byte">125</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Version number of the assembly that generated the data. 
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_version_num</name>
                                  <field_number>53</field_number>
                                  <field_location unit="byte">126</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-version number of the assembly that generated the data.  
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_sub_version_num</name>
                                  <field_number>54</field_number>
                                  <field_location unit="byte">127</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-sub-version number of the assembly that generated the data.  
                                      Value 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_corr_value</name>
                                  <field_number>55</field_number>
                                  <field_location unit="byte">128</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Correction Value -- indicates results of validation of LNA number.
                                      A value 1 to 4 should be used insterad of lna_num (field 33); a value 0 
                                      indicates no validation or correction was made.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>DRVID CHDO (Data Type 11)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>14</fields>
                              <groups>0</groups>
                              <description>Differenced Range versus Integrated Doppler (DRVID) CHDO (Data Type 11)</description>
                              <group_location unit="byte">161</group_location>
                              <group_length unit="byte">42</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the DRVID data CHDO.
                                      Set to 10 because the CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the DRVID data CHDO value field. 
                                      Number of bytes after this item.  Set to 38.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid_type</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      DRVID type.
                                         0 = Unknown; 
                                         1 = Sequential; 
                                         2 = PN
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid_pts</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      DRVID points.  Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      DRVID measurement -- the difference between the group and phase delays of the media.
                                      The difference between two consecutive measured range points minus the scaled 
                                      difference in the uplink and downlink carrier phases over the same time period.
                                      Values -230.0 to 230.0 are allowed.  For definition of range unit, see TRK-2-34 documentation.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prn0</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">15</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Ratio of ranging power (Pr) to noise power spectral density (N0).
                                      Values -10.0 to 90.0 are allowed; value -300.0 indicates no signal.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid_noise</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">19</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      DRVID noise.  Values 0.0 to 230.0 are allowed; value -1.0 indicates invalid.
                                      For definition of range unit, see TRK-2-34 documentation.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid_tol_value</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">23</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>range unit</unit>
                                  <description>
                                      DRVID tolerance value (used for setting DRVID tolerance flag, field 11).  
                                      Provided by customer.  Values -230 to 230 are allowed.
                                      For definition of range unit, see TRK-2-34 documentation.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prn0_resid_tol_value</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">27</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Pr/N0 residual tolerance value (used for setting Pr/N0 residual tolerance flag, field 12).  
                                      Provided by customer.  Values -10.0 to 90.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved.  One byte.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid_tol_flag</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">32</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      DRVID tolerance flag.
                                         0 = Out of tolerance;
                                         1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prn0_resid_tol_flag</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Pr/N0 residual tolerance flag.
                                      0 = Out of tolerance; 
                                      1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>drvid_noise_pts</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">34</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      DRVID noise points -- number of points used in DRVID noise computation.
                                      Values 0 to 200 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve8</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedMSB8</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Reserved.  Eight bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>Carrier Observable                (Data Type 16)</name>
                   <offset unit="byte">25294560</offset>
                   <records>522</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">220</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 134</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>55</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 134 for derived data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">128</group_length>
                              <Field_Binary>
                                  <name>secondary_chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the secondary CHDO.  The following values are possible:
                                         132 = uplink data types;
                                         133 = downlink data types;
                                         134 = derived data types;
                                         135 = interferometric data types;
                                         136 = filtered data types.
                                      Set to 134 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>secondary_chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the secondary CHDO.  
                                      Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                      The following values are possible:
                                          66 = uplink data types;
                                         110 = downlink data types;
                                         124 = derived data types;
                                          88 = interferometric data types;
                                          98 = filtered data types.
                                      Set to 124 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>orig_id</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Originator ID. 
                                      Indicates where this SFDU originated. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_modifier_id</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last modifier ID. 
                                      Indicates where the contents of this SFDU were last modified. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved for future expansion of the next field (scft_id).
                                      A value of 0 is expected.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_id</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">8</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft number.  Values between 1 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rec_seq_num</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Record sequence number (RSN).
                                      Begins with zero; increments by one for each successive tracking 
                                      SFDU of the same data type; wraps around from 2**32-1 to zero. 
                                      Value is reset to zero when the data processing system software is restarted.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>year</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Time tag -- year
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>doy</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">15</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Time tag -- day of year.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sec</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Time tag -- seconds of day.
                                      Values 0.00 to 86400.99 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_day</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Record creation time -- days since 1 January 1958.
                                      Values between 0  and 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_msec</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">27</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Record creation time -- milliseconds of day.
                                      Values between 0 and 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>stn_stream_src</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Station stream source. 
                                         1 = UPL/DTT;
                                         2 = non-UPL-DTT: TRK-2-30; 
                                         3 = non-UPL-DTT: TRK-2-20
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">32</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band. 
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_assembly_num</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink Assembly Number.
                                      Note that this is to allow for potential future cases where there 
                                      might be more than one uplink of the same band at the same antenna.
                                         0 = Unknown or not applicable; 
                                         1 = S- or X-band uplink; 
                                         2 = Ka-band uplink
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_num</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">34</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter number. 
                                      Values 1-3 depend on the transmitter used. 
                                      A value of 0 means that the number is unknown or not applicable.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_status</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmit Status.
                                         0 = Not transmitting out the horn; 
                                         1 = Transmitting out the horn; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_mode</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">36</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter mode.
                                         0 = Low power; 
                                         1 = High power; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cmd_modul_stat</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Command modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_modul_stat</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">38</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Ranging modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_time_tag_delay</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">39</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Transmit time tag delay.
                                      Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values between 0.0 and 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_zheight_corr</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Uplink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_dss_id</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink antenna number.
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">52</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved. One byte.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_chan_num</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink channel number.
                                      Values 0 to 24 are allowed; value of 0 implies unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_mode</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">54</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Predicts mode.
                                      Predicts subset used by downlink channel.
                                         0 = No Predicts; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way; 
                                         4 = Unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_prdx_stn</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station used for predicts. Valid only if prdx_mode is 2 or 3 (field 26).
                                      Values 0 to 255 are allowed; a value 0 means that the number is unknown 
                                      or not valid (e.g., no uplink).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band_dl</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">56</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band assumed by downlink.
                                      Uplink band value used by downlink for turn around computations.
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_delay</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Array delay value -- time delay added to path by arraying equipment.  
                                      Obtained from arraying equipment.  Any measurements include this delay.  
                                      Valid only if Array Flag  (array_flag in field 32) is non-zero.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fts_vld_flag</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Frequency and Timing (FTS) validity.
                                        0 = Equipment is not synced with FTS; 
                                        1 = Equipment is synced with FTS
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_lock_stat</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">66</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier lock status.
                                         0 = Off; 
                                         1 = Open (using only predicts); 
                                         2 = Acquiring, FFT Search; 
                                         3 = Acquiring, Waiting for Lock Decision; 
                                         4 = In Lock; 
                                         5 = Out of Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_flag</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">67</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Array flag.
                                         0 = Non-arrayed; 
                                         1 = Arrayed with Full Spectrum Processing subsystem #1; 
                                         2 = Arrayed with Full Spectrum Processing subsystem #2
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_num</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">68</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Number.  
                                      Values 1 to 4 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_time_tag_delay</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Receive time tag delay.  
                                      Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_zheight_corr</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">77</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Downlink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid. 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_ul_stn</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">81</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated uplink station.  
                                      The uplink station per the validation process.  
                                      Values 0 to 255 are allowed; a value 0 means that the antenna is unknown or not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dop_mode</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">82</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated Doppler mode.  
                                         0 = Unknown or not applicable; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_scft_coh</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated spacecraft coherency.  
                                         0 = Unknown or not applicable; 
                                         1 = Coherent; 
                                         2 = Non-coherent; 
                                         3 = Transponded, non-coherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dl_band</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">84</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated downlink frequency band.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band; 
                                         6 = S or X band (26m stations)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_lock</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">85</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder lock status.
                                         0 = Unknown; 
                                         1 = Out-of-lock; 
                                         2 = In Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_num</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">86</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder number.  
                                      Values 0 to 5 are allowed; value 0 indicates the transponder number is unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve2</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">87</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Reserved. Two bytes.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_freq</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">89</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Spacecraft one-way frequency.  
                                      Values 2.0e9 to 32.3e9 are allowed; set to 0.0 if unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_delay</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">97</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Spacecraft transponder delay (coherent ranging delay).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_num</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">105</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- numerator.
                                      Values 0 to 2**32-1 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_den</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- denominator.
                                      Values 0 to 2**32-1 are allowed; a value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_twnc_stat</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">113</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft two-way non-coherent (TWNC) status.
                                         0 = Unknown; 
                                         1 = OFF; 
                                         2 = ON
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_type</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">114</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft oscillator type.
                                         0 = Unknown; 
                                         1 = AUX OSC (auxiliary oscillator); 
                                         2 = USO (ultra-stable oscillator)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_day</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">115</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Last modification time -- days since 1 January 1958.  
                                      Values 0 to 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_msec</name>
                                  <field_number>50</field_number>
                                  <field_location unit="byte">117</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Last modification time -- milliseconds of day.
                                      Values 0 to 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cnt_time</name>
                                  <field_number>51</field_number>
                                  <field_location unit="byte">121</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Integration time of the counts.  
                                      Values 0.0 to 3600.0 are allowed.  A value  0 indicates Not Applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>version_num</name>
                                  <field_number>52</field_number>
                                  <field_location unit="byte">125</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Version number of the assembly that generated the data. 
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_version_num</name>
                                  <field_number>53</field_number>
                                  <field_location unit="byte">126</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-version number of the assembly that generated the data.  
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_sub_version_num</name>
                                  <field_number>54</field_number>
                                  <field_location unit="byte">127</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-sub-version number of the assembly that generated the data.  
                                      Value 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_corr_value</name>
                                  <field_number>55</field_number>
                                  <field_location unit="byte">128</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Correction Value -- indicates results of validation of LNA number.
                                      A value 1 to 4 should be used insterad of lna_num (field 33); a value 0 
                                      indicates no validation or correction was made.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Carrier Frequency Observables CHDO (Data Type 16)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>17</fields>
                              <groups>0</groups>
                              <description>Carrier Frequency Observables CHDO (Data Type 16)</description>
                              <group_location unit="byte">161</group_location>
                              <group_length unit="byte">60</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the Carrier Frequency Observables data CHDO.
                                      Set to 10 because the CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the Carrier Frequency Observables data CHDO value field.
                                      Number of bytes after this item.  Set to 56.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ref_rcv_type</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reference receiver type.
                                         0 = Unknown;
                                         1 = Downlink Telemetry and Tracking Subsystem (DTT); 
                                         2 = MultiFunction Receiver (MFR)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fabricated_ul_flag</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Fabricated uplink flag -- indicates whether this SFDU was created based on 
                                      uplink records fabricated in support of 3-way ranging.
                                         0 = SFDU created using uplink records originally generated by UPL and validated by TTC software; 
                                         1 = SFDU created using uplink records fabricated by TTC software 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_prefit_resid_tol_value</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Received carrier pre-fit residual tolerance value (provided by customer).
                                      Value used for setting received carrier pre-fit residual tolerance flag.  
                                      Values -1.0e6 to 1.0e6 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve2</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">11</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Reserved. Two bytes.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dop_noise</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Doppler noise. 
                                      Values 0.0 to 1000.0 allowed; value -1.0 indicates invalid.</description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>delta_ff</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Change in downlink frequency since the last sample divided by the current downlink frequency.
                                      Valid only for UPL-DTT antennas.
                                      Values -1.0 to 1.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_sig_lvl</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dBm</unit>
                                  <description>
                                      Received signal level.  
                                      Carrier power (or data power, if suppressed carrier tracking).
                                      Values -190.0 to -45.0 allowed; value -300.0 indicates not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>num_obs</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Number of Observable measurements.
                                      Set to 1.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>obs_cnt_time</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Observable count time.  Integration time of the observables.
                                      Values 0.1 to 3600.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_carr_obs</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Received Carrier observable.  The negative of the difference in the downlink
                                      carrier phase at the measurement time tag and the downlink carrier phase at  
                                      the start of the interval divided by the interval time. 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_prefit_resid</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">43</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Received carrier pre-fit residual (observed minus predicted).
                                      Values -1.0e6 to 1.0e6 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_prefit_resid_vld_flag</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Received carrier pre-fit residual validity indicator.
                                         0 = Invalid pre-fit residual data; 
                                         1 = Valid pre-fit residual data
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_prefit_resid_tol_flag</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">48</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Received carrier pre-fit residual tolerance flag.
                                         0 = Out of tolerance; 
                                         1 = In tolerance; 
                                         2 = Not applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_resid_wt</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">49</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Carrier residual weight.  The weight value applied to residual phase error in carrier 
                                      tracking (weight is 1.0 minus this value in suppressed carrier tracking).
                                      Values 0.0 to 1.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve8</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedMSB8</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Reserved. Eight bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>Total Phase                       (Data Type 17)</name>
                   <offset unit="byte">25409400</offset>
                   <records>522</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">236</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 134</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>55</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 134 for derived data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">128</group_length>
                              <Field_Binary>
                                  <name>secondary_chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the secondary CHDO.  The following values are possible:
                                         132 = uplink data types;
                                         133 = downlink data types;
                                         134 = derived data types;
                                         135 = interferometric data types;
                                         136 = filtered data types.
                                      Set to 134 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>secondary_chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the secondary CHDO.  
                                      Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                      The following values are possible:
                                          66 = uplink data types;
                                         110 = downlink data types;
                                         124 = derived data types;
                                          88 = interferometric data types;
                                          98 = filtered data types.
                                      Set to 124 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>orig_id</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Originator ID. 
                                      Indicates where this SFDU originated. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_modifier_id</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last modifier ID. 
                                      Indicates where the contents of this SFDU were last modified. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved for future expansion of the next field (scft_id).
                                      A value of 0 is expected.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_id</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">8</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft number.  Values between 1 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rec_seq_num</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Record sequence number (RSN).
                                      Begins with zero; increments by one for each successive tracking 
                                      SFDU of the same data type; wraps around from 2**32-1 to zero. 
                                      Value is reset to zero when the data processing system software is restarted.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>year</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Time tag -- year
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>doy</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">15</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Time tag -- day of year.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sec</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Time tag -- seconds of day.
                                      Values 0.00 to 86400.99 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_day</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Record creation time -- days since 1 January 1958.
                                      Values between 0  and 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_msec</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">27</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Record creation time -- milliseconds of day.
                                      Values between 0 and 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>stn_stream_src</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Station stream source. 
                                         1 = UPL/DTT;
                                         2 = non-UPL-DTT: TRK-2-30; 
                                         3 = non-UPL-DTT: TRK-2-20
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">32</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band. 
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_assembly_num</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink Assembly Number.
                                      Note that this is to allow for potential future cases where there 
                                      might be more than one uplink of the same band at the same antenna.
                                         0 = Unknown or not applicable; 
                                         1 = S- or X-band uplink; 
                                         2 = Ka-band uplink
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_num</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">34</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter number. 
                                      Values 1-3 depend on the transmitter used. 
                                      A value of 0 means that the number is unknown or not applicable.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_status</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmit Status.
                                         0 = Not transmitting out the horn; 
                                         1 = Transmitting out the horn; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_mode</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">36</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter mode.
                                         0 = Low power; 
                                         1 = High power; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cmd_modul_stat</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Command modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_modul_stat</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">38</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Ranging modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_time_tag_delay</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">39</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Transmit time tag delay.
                                      Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values between 0.0 and 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_zheight_corr</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Uplink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_dss_id</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink antenna number.
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">52</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved. One byte.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_chan_num</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink channel number.
                                      Values 0 to 24 are allowed; value of 0 implies unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_mode</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">54</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Predicts mode.
                                      Predicts subset used by downlink channel.
                                         0 = No Predicts; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way; 
                                         4 = Unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_prdx_stn</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station used for predicts. Valid only if prdx_mode is 2 or 3 (field 26).
                                      Values 0 to 255 are allowed; a value 0 means that the number is unknown 
                                      or not valid (e.g., no uplink).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band_dl</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">56</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band assumed by downlink.
                                      Uplink band value used by downlink for turn around computations.
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_delay</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Array delay value -- time delay added to path by arraying equipment.  
                                      Obtained from arraying equipment.  Any measurements include this delay.  
                                      Valid only if Array Flag  (array_flag in field 32) is non-zero.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fts_vld_flag</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Frequency and Timing (FTS) validity.
                                        0 = Equipment is not synced with FTS; 
                                        1 = Equipment is synced with FTS
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_lock_stat</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">66</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier lock status.
                                         0 = Off; 
                                         1 = Open (using only predicts); 
                                         2 = Acquiring, FFT Search; 
                                         3 = Acquiring, Waiting for Lock Decision; 
                                         4 = In Lock; 
                                         5 = Out of Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_flag</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">67</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Array flag.
                                         0 = Non-arrayed; 
                                         1 = Arrayed with Full Spectrum Processing subsystem #1; 
                                         2 = Arrayed with Full Spectrum Processing subsystem #2
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_num</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">68</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Number.  
                                      Values 1 to 4 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_time_tag_delay</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Receive time tag delay.  
                                      Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_zheight_corr</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">77</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Downlink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid. 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_ul_stn</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">81</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated uplink station.  
                                      The uplink station per the validation process.  
                                      Values 0 to 255 are allowed; a value 0 means that the antenna is unknown or not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dop_mode</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">82</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated Doppler mode.  
                                         0 = Unknown or not applicable; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_scft_coh</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated spacecraft coherency.  
                                         0 = Unknown or not applicable; 
                                         1 = Coherent; 
                                         2 = Non-coherent; 
                                         3 = Transponded, non-coherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dl_band</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">84</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated downlink frequency band.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band; 
                                         6 = S or X band (26m stations)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_lock</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">85</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder lock status.
                                         0 = Unknown; 
                                         1 = Out-of-lock; 
                                         2 = In Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_num</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">86</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder number.  
                                      Values 0 to 5 are allowed; value 0 indicates the transponder number is unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve2</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">87</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Reserved. Two bytes.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_freq</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">89</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Spacecraft one-way frequency.  
                                      Values 2.0e9 to 32.3e9 are allowed; set to 0.0 if unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_delay</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">97</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Spacecraft transponder delay (coherent ranging delay).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_num</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">105</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- numerator.
                                      Values 0 to 2**32-1 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_den</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- denominator.
                                      Values 0 to 2**32-1 are allowed; a value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_twnc_stat</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">113</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft two-way non-coherent (TWNC) status.
                                         0 = Unknown; 
                                         1 = OFF; 
                                         2 = ON
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_type</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">114</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft oscillator type.
                                         0 = Unknown; 
                                         1 = AUX OSC (auxiliary oscillator); 
                                         2 = USO (ultra-stable oscillator)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_day</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">115</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Last modification time -- days since 1 January 1958.  
                                      Values 0 to 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_msec</name>
                                  <field_number>50</field_number>
                                  <field_location unit="byte">117</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Last modification time -- milliseconds of day.
                                      Values 0 to 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cnt_time</name>
                                  <field_number>51</field_number>
                                  <field_location unit="byte">121</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Integration time of the counts.  
                                      Values 0.0 to 3600.0 are allowed.  A value  0 indicates Not Applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>version_num</name>
                                  <field_number>52</field_number>
                                  <field_location unit="byte">125</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Version number of the assembly that generated the data. 
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_version_num</name>
                                  <field_number>53</field_number>
                                  <field_location unit="byte">126</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-version number of the assembly that generated the data.  
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_sub_version_num</name>
                                  <field_number>54</field_number>
                                  <field_location unit="byte">127</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-sub-version number of the assembly that generated the data.  
                                      Value 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_corr_value</name>
                                  <field_number>55</field_number>
                                  <field_location unit="byte">128</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Correction Value -- indicates results of validation of LNA number.
                                      A value 1 to 4 should be used insterad of lna_num (field 33); a value 0 
                                      indicates no validation or correction was made.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Total Count Phase Observable CHDO (Data Type 17)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>22</fields>
                              <groups>0</groups>
                              <description>Total Count Phase Observable CHDO (Data Type 17)</description>
                              <group_location unit="byte">161</group_location>
                              <group_length unit="byte">76</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the Total Count Phase Observables data CHDO.
                                      Set to 10 because the CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the Total Count Phase Observables data CHDO value field.
                                      Number of bytes after this item.  Set to 72.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ref_rcv_type</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reference receiver type.
                                         0 = Unknown;
                                         1 = Downlink Telemetry and Tracking Subsystem (DTT); 
                                         2 = MultiFunction Receiver (MFR)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fabricated_ul_flag</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Fabricated uplink flag -- indicates whether this SFDU was created based on 
                                      uplink records fabricated in support of 3-way ranging.
                                         0 = SFDU created using uplink records originally generated by UPL and validated by TTC software; 
                                         1 = SFDU created using uplink records fabricated by TTC software 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_prefit_resid_tol_value</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Total Count Phase pre-fit residual tolerance value (provided by customer).
                                      Value used for setting total count phase pre-fit residual tolerance flag. 
                                      Values -1.0e6 to 1.0e6 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve2</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">11</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Reserved. Two bytes.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dop_noise</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Doppler noise. 
                                      Values 0.0 to 1000.0 allowed; value -1.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>delta_ff</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Change in downlink frequency since the last sample divided by the current downlink frequency.
                                      Valid only for UPL-DTT antennas.
                                      Values -1.0 to 1.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_sig_lvl</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dBm</unit>
                                  <description>
                                      Received signal level.  
                                      Carrier power (or data power, if suppressed carrier tracking).
                                      Values -190.0 to -45.0 allowed; value -300.0 indicates not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>num_obs</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Number of Observable measurements.
                                      Set to 1.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>obs_cnt_time</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Observable count time. Integration time of the observables.
                                      Values 0.1 to 3600.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_st_year</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Total Count Phase observable start time -- year.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_st_doy</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Total Count Phase observable start time -- day of year.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_st_sec</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">39</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Total Count Phase observable start time -- second.
                                      Values 0.00 to 86400.999 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_obs_hi</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Negative of Total Count Phase observable - high part  
                                      Total integer phase cycles divided by 2**32.
                                      Values 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_obs_lo</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Negative of Total Count Phase observable - low part  
                                      Total integer phase cycles modulo 2**32.
                                      Values 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_obs_frac</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Negative of Total Count Phase observable - fractional part  
                                      Fractional phase cycles multiplied by 2**32.
                                      Values 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_prefit_resid</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">59</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Total Count Phase pre-fit residual (observed minus predicted).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_prefit_resid_vld_flag</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">63</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Total Count Phase pre-fit residual validity indicator.
                                         0 = Invalid pre-fit residual data; 
                                         1 = Valid pre-fit residual data
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_prefit_resid_tol_flag</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">64</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Total Count Phase pre-fit residual tolerance flag.
                                         0 = Out of tolerance; 
                                         1 = In tolerance; 
                                         2 = Not applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_resid_wt</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Carrier residual weight.  The weight value applied to residual phase error in carrier 
                                      tracking (weight is 1.0 minus this value in suppressed carrier tracking).
                                      Values 0.0 to 1.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve8</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>UnsignedMSB8</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Reserved. Eight bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
      </File_Area_Observational>
</Product_Observational>
