<?xml version="1.0" encoding="UTF-8"?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1D00.sch"
   schematypens="http://purl.oclc.org/dsdl/schematron"?>
<Product_Observational
   xmlns="http://pds.nasa.gov/pds4/pds/v1"
   xmlns:pds="http://pds.nasa.gov/pds4/pds/v1"
   xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
   xsi:schemaLocation="
      http://pds.nasa.gov/pds4/pds/v1
      https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1D00.xsd
">

       <Identification_Area>
             <logical_identifier>urn:nasa:pds:mess-rs-raw:data-tnf:122012140sc236dss45_tnf</logical_identifier>
             <version_id>1.0</version_id>
             <title>MESSENGER  Radio Science Tracking and Navigation File (TNF)
                    From: 2012-07-19T21:22:14Z To 2012-07-20T01:51:24Z
                    DSN: 45
             </title>
             <information_model_version>1.13.0.0</information_model_version>
             <product_class>Product_Observational</product_class>
             <Citation_Information>
                   <author_list>Verma, A. K.; Perry, M. E.; Lemoine, F. G.; Smith, D. E.; Ensor, S.; Reid, M. R.</author_list>
                   <publication_year>2020</publication_year>
                   <description>MESSENGER Radio Science Tracking and Navigation File (TNF)</description>
             </Citation_Information>
             <Modification_History>
                   <Modification_Detail>
                         <modification_date>2020-10-12</modification_date>
                         <version_id>1.0</version_id>
                         <description>
                                This data file has been migrated from PDS3 PRODUCT_ID 122012140SC236DSS45_234
                                in data set MESS-V/H-RSS-1-EDR-RAWDATA-V1.0 to PDS4. The data file has been sorted according
                                to data type and a new PDS4 label was created as part of the migration process.
                         </description>
                  </Modification_Detail>
             </Modification_History>
       </Identification_Area>
       <Observation_Area>
             <Time_Coordinates>
                   <start_date_time>2012-07-19T21:22:14Z</start_date_time>
                   <stop_date_time>2012-07-20T01:51:24Z</stop_date_time>
             </Time_Coordinates>
             <Primary_Result_Summary>
                   <purpose>Science</purpose>
                   <processing_level>Raw</processing_level>
                   <description>MESSENGER raw radio tracking data</description>
                   <Science_Facets>
                           <discipline_name>Radio Science</discipline_name>
                   </Science_Facets>
             </Primary_Result_Summary>
             <Investigation_Area>
                   <name>MErcury Surface, Space ENvironment, GEochemistry, and Ranging Mission</name>
                   <type>Mission</type>
                   <Internal_Reference>
                         <lid_reference>urn:nasa:pds:context:investigation:mission.messenger</lid_reference>
                         <reference_type>data_to_investigation</reference_type>
                   </Internal_Reference>
             </Investigation_Area>
             <Observing_System>
                   <Observing_System_Component>
                         <name>MESSENGER</name>
                         <type>Spacecraft</type>
                         <Internal_Reference>
                               <lid_reference>urn:nasa:pds:context:instrument_host:spacecraft.mess</lid_reference>
                               <reference_type>is_instrument_host</reference_type>
                         </Internal_Reference>
                   </Observing_System_Component>
                   <Observing_System_Component>
                         <name>RSS</name>
                         <type>Instrument</type>
                         <Internal_Reference>
                               <lid_reference>urn:nasa:pds:context:instrument:rss.mess</lid_reference>
                               <reference_type>is_instrument</reference_type>
                         </Internal_Reference>
                   </Observing_System_Component>
                   <Observing_System_Component>
                         <name>NASA Deep Space Network</name>
                         <type>Observatory</type>
                         <Internal_Reference>
                               <lid_reference>urn:nasa:pds:context:facility:observatory.dsn</lid_reference>
                               <reference_type>is_facility</reference_type>
                         </Internal_Reference>
                   </Observing_System_Component>                                                                                                                                                   
                   <Observing_System_Component>
                         <name>DSN Instrumentation</name>
                         <type>Instrument</type>
                         <Internal_Reference>
                               <lid_reference>urn:nasa:pds:context:instrument:dsn.rss</lid_reference>
                               <reference_type>is_instrument</reference_type>
                         </Internal_Reference>
                   </Observing_System_Component>
                    
                   <Observing_System_Component>
                         <name>DSN Antenna DSS 45</name>
                         <type>Telescope</type>
                         <Internal_Reference>
                               <lid_reference>urn:nasa:pds:context:telescope:canberra.dss45_34m</lid_reference>
                               <reference_type>is_telescope</reference_type>
                         </Internal_Reference>
                   </Observing_System_Component>
             </Observing_System>
             <Target_Identification>
                   <name>Mercury</name>
                   <type>Planet</type>
                   <Internal_Reference>
                         <lid_reference>urn:nasa:pds:context:target:planet.mercury</lid_reference>
                         <reference_type>data_to_target</reference_type>
                   </Internal_Reference>
             </Target_Identification>
       </Observation_Area>
       <Reference_List>
            <Internal_Reference>
                  <lid_reference>urn:nasa:pds:radiosci.documentation:dsn.trk-2-34:2008-02-29</lid_reference>
                  <reference_type>data_to_document</reference_type>
                  <comment>
                      Reference document for the Tracking and Navigation File (TNF) data.
                      For data collected earlier or later than this document, consult other
                      document products in the same collection.
 
                      IMPORTANT: Records delivered originally by the DSN were in time order, with records for
                      different TNF data types interleaved.  Retaining that structure would have made the PDS
                      label many times larger than the data file itself.  To keep the size of the label 
                      manageable, the original file was sorted so that all records of a single TNF data type are
                      together.  The blocks of homogeneous records were then concatenated -- TNF data type 0,
                      followed by TNF data type 1, ... followed by TNF data type 17.  When there were no records of
                      a given TNF data type, that block was omitted.  Within each block, the records remain in
                      time order.  The label is still long, since each block is a Table_Binary with
                      many records containing many fields.  But there will never be more than 18 blocks and
                      never more than 18 Table_Binary definitions.  The document referenced here correctly
                      describes the record formats.  Note, however, that the records are no longer in absolute
                      time order.  They are in time order within each block and the blocks are ordered by
                      TNF data type.
                  </comment>
            </Internal_Reference>
            <Source_Product_External>
                  <external_source_product_identifier>MESS-V/H-RSS-1-EDR-RAWDATA-V1.0:122012140SC236DSS45_234</external_source_product_identifier>
                  <reference_type>data_to_raw_source_product</reference_type>
                  <curating_facility>PDS Geosciences Node</curating_facility>
                  <description>
                      The value for external_source_product_identifier is constructed from the
                      PDS3 DATA_SET_ID, an ASCII colon character, and the PDS3 PRODUCT_ID.
                  </description>                                                                     
            </Source_Product_External>
       </Reference_List>
       <File_Area_Observational>
             <File>
                   <file_name>122012140sc236dss45_tnf.dat</file_name>
                   <creation_date_time>2020-10-12T11:17:46</creation_date_time>
                   <file_size unit="byte">7428394</file_size>
                   <md5_checksum>eea16befbe587d05750360383c285378</md5_checksum>
             </File>
             <Table_Binary>
                   <name>Uplink Carrier Phase              (Data Type 00)</name>
                   <offset unit="byte">0</offset>
                   <records>16127</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">182</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 132</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>32</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 132 for uplink data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">70</group_length>
                              <Field_Binary>
                                   <name>secondary_chdo_type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Type attribute of the secondary CHDO.  The following values are possible:
                                            132 = uplink data types;
                                            133 = downlink data types;
                                            134 = derived data types;
                                            135 = interferometric data types;
                                            136 = filtered data types.
                                         Set to 132 for this Table.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>secondary_chdo_length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Length attribute of the secondary CHDO.  
                                         Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                         The following values are possible:
                                             66 = uplink data types;
                                            110 = downlink data types;
                                            124 = derived data types;
                                             88 = interferometric data types;
                                             98 = filtered data types.
                                          Set to 66 for this Table.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>orig_id</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Originator ID.
                                         Indicates where this SFDU originated. 
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>last_modifier_id</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Last modifier ID.
                                         Indicates where the contents of this SFDU were last modified. 
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve1a</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Reserved for future expansion of the next field (scft_id).
                                         A value of 0 is expected.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>scft_id</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Spacecraft number.  Values between 1 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>upl_rec_seq_num</name>
                                   <field_number>7</field_number>
                                   <field_location unit="byte">9</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <description>
                                       Uplink record sequence number (UPL RSN).
                                       This is the record sequence number reported by the uplink subsystem (UPL) equipment.
                                         Values between 0 and 2**32-1 are allowed.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>rec_seq_num</name>
                                   <field_number>8</field_number>
                                   <field_location unit="byte">13</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <description>
                                         Record sequence number (RSN).
                                         Begins with zero, then increments by one for each successive uplink tracking 
                                         SFDU of the same data type.  Wraps around from 2**32-1 to zero. Value is reset 
                                         to zero when the data processing system software is restarted.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>year</name>
                                   <field_number>9</field_number>
                                   <field_location unit="byte">17</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Time tag -- year
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>doy</name>
                                   <field_number>10</field_number>
                                   <field_location unit="byte">19</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Time tag -- day of year
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sec</name>
                                   <field_number>11</field_number>
                                   <field_location unit="byte">21</field_location>
                                   <data_type>IEEE754MSBDouble</data_type>
                                   <field_length unit="byte">8</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Time tag -- seconds of day
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rct_day</name>
                                   <field_number>12</field_number>
                                   <field_location unit="byte">29</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>day</unit>
                                   <description>
                                         Record creation time -- days since 1 January 1958.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rct_msec</name>
                                   <field_number>13</field_number>
                                   <field_location unit="byte">31</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <field_format>%10d</field_format>
                                   <unit>millisecond</unit>
                                   <description>
                                         Record creation time -- milliseconds of day
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_dss_id</name>
                                   <field_number>14</field_number>
                                   <field_location unit="byte">35</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink antenna number.  A value between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_band</name>
                                   <field_number>15</field_number>
                                   <field_location unit="byte">36</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink frequency band.
                                            0 = Unknown; 
                                            1 = S-band; 
                                            2 = X-band; 
                                            3 = Ka-band; 
                                            4 = Ku-band; 
                                            5 = L-band
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_assembly_num</name>
                                   <field_number>16</field_number>
                                   <field_location unit="byte">37</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink Assembly Number.
                                         Note that this is to allow for potential future cases where there might be more 
                                         than one uplink of the same band at the same antenna.
                                            0 = Invalid/unknown; 
                                            1 = S- or X-band uplink; 
                                            2 = Ka-band uplink
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_num</name>
                                   <field_number>17</field_number>
                                   <field_location unit="byte">38</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmitter number.  Value depends on transmitter used.  
                                         Values between 0 and 3 are allowed;  0 indicates unknown.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_stat</name>
                                   <field_number>18</field_number>
                                   <field_location unit="byte">39</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmit status.
                                            0 = Not transmitting out the horn; 
                                            1 = Transmitting out the horn; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_mode</name>
                                   <field_number>19</field_number>
                                   <field_location unit="byte">40</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmitter mode.
                                            0 = Low power; 
                                            1 = High power; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>cmd_modul_stat</name>
                                   <field_number>20</field_number>
                                   <field_location unit="byte">41</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Command modulation status.
                                            0 = OFF; 
                                            1 = ON; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rng_modul_stat</name>
                                   <field_number>21</field_number>
                                   <field_location unit="byte">42</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Ranging modulation status.
                                            0 = OFF; 
                                            1 = ON; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>fts_vld_flag</name>
                                   <field_number>22</field_number>
                                   <field_location unit="byte">43</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Frequency and Timing (FTS) validity.
                                            0 = Equipment is not synced with FTS; 
                                            1 = Equipment is synced with FTS
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_software_version</name>
                                   <field_number>23</field_number>
                                   <field_location unit="byte">44</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink Software version number.
                                         Gives the version major op code for the uplink software.
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_time_tag_delay</name>
                                   <field_number>24</field_number>
                                   <field_location unit="byte">45</field_location>
                                   <data_type>IEEE754MSBDouble</data_type>
                                   <field_length unit="byte">8</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Transmit time tag delay.
                                         Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                         Values 0.0 to 1.0 are allowed.  Value of -1.0 indicates invalid (or not provided).
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_zheight_corr</name>
                                   <field_number>25</field_number>
                                   <field_location unit="byte">53</field_location>
                                   <data_type>IEEE754MSBSingle</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Uplink Z-height correction.
                                         Values -1.0 to 1.0 are possible.  Value -99.0 indicates invalid.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>mod_day</name>
                                   <field_number>26</field_number>
                                   <field_location unit="byte">57</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Last modification time -- days since 1 January 1958.
                                         Values 0 to 2**16-1 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>mod_msec</name>
                                   <field_number>27</field_number>
                                   <field_location unit="byte">59</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <unit>milliseconds</unit>
                                   <description>
                                         Last modification time -- milliseconds of day.
                                         Values 0 to 86400999 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>version_num</name>
                                   <field_number>28</field_number>
                                   <field_location unit="byte">63</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Version number of the assembly that generated the data. 
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sub_version_num</name>
                                   <field_number>29</field_number>
                                   <field_location unit="byte">64</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Sub-version number of the assembly that generated the data.
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sub_sub_version_num</name>
                                   <field_number>30</field_number>
                                   <field_location unit="byte">65</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Sub-sub-version number of the assembly that generated the data.
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve1b</name>
                                   <field_number>31</field_number>
                                   <field_location unit="byte">66</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <field_format>%1d</field_format>
                                   <description>
                                         Reserved. One byte.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve4a</name>
                                   <field_number>32</field_number>
                                   <field_location unit="byte">67</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <field_format>%10d</field_format>
                                   <description>
                                         Reserved. Four bytes.
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Uplink Carrier Phase CHDO (Data Type 0)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>19</fields>
                              <groups>0</groups>
                              <description>Uplink Carrier Phase CHDO (Data Type 0)</description>
                              <group_location unit="byte">103</group_location>
                              <group_length unit="byte">80</group_length>
                              <Field_Binary>
                                    <name>chdo_type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          Type attribute of the uplink carrier phase data CHDO.
                                          A value 10 is expected, indicating that the CHDO contains binary data.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>chdo_length</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">3</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          Length attribute of the uplink carrier phase data CHDO value field.
                                          Number of bytes after this item.  A value of 76 is expected.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ul_hi_phs_cycles</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>UnsignedMSB4</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <field_format>%10d</field_format>
                                    <description>
                                          High part phase data: total integer phase cycles divided by 2**32.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ul_lo_phs_cycles</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>UnsignedMSB4</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          Low part phase data: total integer phase cycles modulo 2**32.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ul_frac_phs_cycles</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB4</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <field_format>%10d</field_format>
                                    <description>
                                          Fractional phase data cycles: fractional phase cycles multiplied by 2**32
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ramp_freq</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">17</field_location>
                                    <data_type>IEEE754MSBDouble</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>hertz</unit>
                                    <description>
                                          The base frequency of a ramped uplink transmission.
                                          Values 2.0e9 to 34.7e9 are expected.  A value of 0. indicates an invalid or unknown value.
                                          Precision varies with band (phase data give higher precision):   
                                             S-band  = 0.5 microHz; 
                                             X-band  = 1.6 microHz;
                                             Ka-band = 7.7 microHz
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ramp_rate</name>
                                    <field_number>7</field_number>
                                    <field_location unit="byte">25</field_location>
                                    <data_type>IEEE754MSBDouble</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>Hz/s</unit>
                                    <description>
                                          Ramp rate of an uplink transmission.  
                                          Allowed values are -3.2e5 to 3.2e5.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>transmit_switch_stat</name>
                                    <field_number>8</field_number>
                                    <field_location unit="byte">33</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <field_format>%3d</field_format>
                                    <description>
                                          Transmitter switch status.
                                             0 = Antenna; 
                                             1 = Water load; 
                                             2 = Invalid/unknown
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>ramp_type</name>
                                    <field_number>9</field_number>
                                    <field_location unit="byte">34</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <field_format>%3d</field_format>
                                    <description>
                                          Ramp type.
                                             0 = Snap; 
                                             1 = Start of new ramp; 
                                             2 = Medial report; 
                                             3 = Periodic report; 
                                             4 = End of ramps; 
                                             5 = Ramping terminated by operator; 
                                             6 = Invalid/unknown
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>transmit_op_pwr</name>
                                    <field_number>10</field_number>
                                    <field_location unit="byte">35</field_location>
                                    <data_type>IEEE754MSBSingle</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <unit>watt</unit>
                                    <description>
                                          Transmitter output power.
                                          Values 0. to 500,000.0 are allowed.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>sup_data_id</name>
                                    <field_number>11</field_number>
                                    <field_location unit="byte">39</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <description>
                                          Support data ID.  Name of the frequency predicts set used.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>sup_data_rev</name>
                                    <field_number>12</field_number>
                                    <field_location unit="byte">47</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <field_format>%8s</field_format>
                                    <description>
                                          Support data revision. Revision of the frequency predicts set used.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>prdx_time_offset</name>
                                    <field_number>13</field_number>
                                    <field_location unit="byte">55</field_location>
                                    <data_type>IEEE754MSBDouble</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>second</unit>
                                    <description>
                                          Predicts time offset.  Seconds added to current time.
                                          Values -31,536,000.0 to 31,536,000.0 are allowed.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>prdx_freq_offset</name>
                                    <field_number>14</field_number>
                                    <field_location unit="byte">63</field_location>
                                    <data_type>IEEE754MSBDouble</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>hertz</unit>
                                    <description>
                                          Predicts frequency offset.  Hz added to predicted value.
                                          Values -4.8e6 to 4.8e6 are allowed.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>time_tag_corr_flag</name>
                                    <field_number>15</field_number>
                                    <field_location unit="byte">71</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          Time tag correction flag. Indicates results of validation of the block time tag.
                                             0 = No validation attempted; 
                                             1 = Validated, no change; 
                                             2 = Validated, changed
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>type_time_corr_flag</name>
                                    <field_number>16</field_number>
                                    <field_location unit="byte">72</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          Type of time tag correction flag. Indicates what type of time tag correction was made.
                                             0 = No correction; 
                                             1 = Year correction; 
                                             2 = DOY correction; 
                                             3 = Both Year and DOY correction
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>fabricated_sfdu_flag</name>
                                    <field_number>17</field_number>
                                    <field_location unit="byte">73</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          Fabricated SFDU Flag. Indicates whether this SFDU was artificially 
                                          fabricated in support of 3-way ranging. 
                                             0 = Originally generated by UPL and validated by TTC software; 
                                             1 = Fabricated by TTC software
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>reserve1c</name>
                                    <field_number>18</field_number>
                                    <field_location unit="byte">74</field_location>
                                    <data_type>UnsignedByte</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          Reserved. One byte.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>reserve6a</name>
                                    <field_number>19</field_number>
                                    <field_location unit="byte">75</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">6</field_length>
                                    <description>
                                          Reserved. Six bytes.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>Downlink Carrier Phase            (Data Type 01)</name>
                   <offset unit="byte">2935114</offset>
                   <records>11588</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">378</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 133</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>49</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 133 for downlink data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">114</group_length>
                              <Field_Binary>
                                  <name>secondary_chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the secondary CHDO.  The following values are possible:
                                         132 = uplink data types;
                                         133 = downlink data types;
                                         134 = derived data types;
                                         135 = interferometric data types;
                                         136 = filtered data types.
                                      Set to 133 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>secondary_chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the secondary CHDO.  
                                      Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                      The following values are possible:
                                          66 = uplink data types;
                                         110 = downlink data types;
                                         124 = derived data types;
                                          88 = interferometric data types;
                                          98 = filtered data types.
                                      Set to 110 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>orig_id</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Originator ID.
                                      Indicates where this SFDU originated. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_modifier_id</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last modifier ID.
                                      Indicates where the contents of this SFDU were last modified. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved for future expansion of the next field (scft_id).
                                      A value of 0 is expected.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_id</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">8</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft number.  Values between 1 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dtt_rec_seq_num</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      RDownlink record sequence number (DTT RSN) -- the number reported by
                                      the downlink subsystem (DTT) equipment.  Values between 0 and 2**32-1
                                      are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rec_seq_num</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Record sequence number (RSN).
                                      Begins with zero, then increments by one for each successive downlink tracking 
                                      SFDU of the same data type.  Wraps around from 2**32-1 to zero. Value is reset 
                                      to zero when the data processing system software is restarted.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>year</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Time tag -- year
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>doy</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">19</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Time tag -- day of year.
                                      Values between 1 and 366 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sec</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">21</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Time tag -- seconds of day.
                                      Values between 0.00 and 86400.99 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_day</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Record creation time -- days since 1 January 1958.
                                      Values between 0 and 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_msec</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Record creation time -- milliseconds of day.
                                      Values between 0 and 86400999 are allowed.
                                  </description>
                              </Field_Binary>                              
                              <Field_Binary>
                                  <name>dl_dss_id</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink antenna number.
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_band</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">36</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink frequency band.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band;
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_chan_num</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink channel number.
                                      Values between 1 and 24 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_mode</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">38</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Predicts mode -- the predicts subset used by downlink channel.
                                         0 = No Predicts; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_prdx_stn</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">39</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station used for predicts.  Valid only if prdx_mode (field 17) is 2 or 3. 
                                      Values 0 to 255 are allowed; a value 0 means that the number is unknown 
                                      or not valid (e.g., no uplink).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band_dl</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">40</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band assumed by downlink.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_delay</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">41</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Array delay value -- time delay added to path by arraying equipment.  
                                      Obtained from arraying equipment.  Any measurements include this delay.  
                                      Values 0.0 to 1.0 are allowed.  
                                      Valid only if Array Flag (array_flag is field 23) is non-zero.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fts_vld_flag</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">49</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Frequency and Timing (FTS) validity.
                                         0 = Equipment is not synced with FTS; 
                                         1 = Equipment is synced with FTS
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_lock_stat</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">50</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier lock status.
                                         0 = Off; 
                                         1 = Open (only using predicts); 
                                         2 = Acquiring, FFT Search; 
                                         3 = Acquiring, Waiting for Lock Decision; 
                                         4 = In Lock; 
                                         5 = Out of Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_flag</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Array flag.
                                         0 = Not arrayed; 
                                         1 = Arrayed with Full Spectrum Processing subsystem #1; 
                                         2 = Arrayed with Full Spectrum Processing subsystem #2
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>polarization</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">52</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Polarization.
                                         0 = RCP; 
                                         1 = LCP;
                                         2 = Unknown;
                                         3 = Not applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>diplxr_stat</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Diplexer status.
                                         0 = Low noise; 
                                         1 = Diplexed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_num</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">54</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Number.
                                      Values 0-4 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rf_if_chan_num</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      RF-to-IF Downconverter Channel number.
                                      Values 1 or 2 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>if_num</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">56</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      IF input number -- defines path into downlink channel.
                                      Values 1 to 3 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_time_tag_delay</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Receive time tag delay.  
                                      Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).
                                      Values 0.0 to 1.0 are allowed; value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_zheight_corr</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Downlink Z-height correction. 
                                      Values -1.000 to 1.000 are allowed; value -99.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_ul_stn</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated uplink station.  
                                      The uplink station per the validation process.  
                                      Values 0 to 255 are allowed; value 0 means that the antenna is unknown or not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dop_mode</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">70</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated Doppler mode.  
                                         0 = Unknown or not applicable; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_scft_coh</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">71</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated spacecraft coherency.  
                                         0 = Unknown or not applicable; 
                                         1 = Coherent; 
                                         2 = Non-coherent; 
                                         3 = Transponded, non-coherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_lock</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">72</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder lock status.
                                         0 = Unknown; 
                                         1 = Out-of-lock; 
                                         2 = In Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_num</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">73</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder number.
                                      Values 1 to 5 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_software_version</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">74</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink software version number -- the DCC software version major op code.
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_freq</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">75</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Spacecraft one-way frequency.
                                      Values 2.0e9 to 32.3e9 are allowed; value 0.0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_delay</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Spacecraft transponder delay (the coherent ranging delay).  
                                      Values 0.0 to 1.0 are allowed; value -1.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_num</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">91</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- numerator.
                                      Values 0 to 2**32-1 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_den</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">95</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- denominator.
                                      Values 0 to 2**32-1 are allowed; value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_twnc_stat</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">99</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft two-way non-coherent (TWNC) status.
                                         0 = Unknown;
                                         1 = OFF; 
                                         2 = ON
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_type</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">100</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft oscillator type.
                                         0 = Unknown; 
                                         1 = AUX OSC (auxiliary oscillator); 
                                         2 = USO (ultra-stable oscillator)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_day</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">101</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Last modification time -- days since 1 January 1958.
                                      Values 0 to 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_msec</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">103</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Last modification time -- milliseconds of day.
                                      Values 0 to 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>version_num</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">107</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Version number of the assembly that generated the data. 
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_version_num</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">108</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-version number of the assembly that generated the data.
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_sub_version_num</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-sub-version number of the assembly that generated the data.
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_corr_value</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">110</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Correction Value -- indicates results of validation of LNA number. 
                                      Values 1 to 4 are allowed and should be substituted for lna_num (field 26).
                                      Value 0 indicates no validation or correction was made.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve4</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">111</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Reserved. Four bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Downlink Carrier Phase CHDO (Data Type 1)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>59</fields>
                              <groups>0</groups>
                              <description>Downlink Carrier Phase CHDO (Data Type 1)</description>
                              <group_location unit="byte">147</group_location>
                              <group_length unit="byte">232</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the downlink carrier phase data CHDO. 
                                      Set to 10 because the CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the downlink carrier phase data CHDO value field.
                                      Number of bytes after this item.  Set to 228 for this CHDO.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_loop_bw</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Carrier tracking loop bandwidth.
                                      Values from 0.1 to 50.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pcn0</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Ratio of carrier power (Pc) to noise power spectral density (N0).
                                      Values from 0.0 to 90.0 are allowed; value -300.0 indicates no signal.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pcn0_resid</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Pc/N0 residual -- actual value minus predicted value.
                                      Values -90.0 to 90.0 are allowed; value -300.0 indicates
                                      no signal or carrier is suppressed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pdn0</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Ratio of data power (Pd) to noise power spectral density (N0).  
                                      Values 0.0 to 90.0 are allowed; value -300.0 indicates no signal.</description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>pdn0_resid</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">21</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dB*Hz</unit>
                                  <description>
                                      Pd/N0 residual -- actual value minus predicted value.
                                      Values -90.0 to 90.0 are allowed; value -300.0 indicates no signal.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>system_noise_temp</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>K</unit>
                                  <description>
                                      System Noise Temperature.
                                      Values 0.1 to 2000.0 are allowed.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_0</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 0 -- high part.
                                      Total integer phase in cycles at (time tag + 0.0 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_0</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 0 -- low part.
                                      Total integer phase in cycles at (time tag + 0.0 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_0</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 0 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.0 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              
                              <Field_Binary>
                                  <name>phs_hi_1</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">41</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 1 -- high part.
                                      Total integer phase in cycles at (time tag + 0.1 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_1</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">45</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 1 -- low part.
                                      Total integer phase in cycles at (time tag + 0.1 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_1</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">49</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 1 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.1 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              
                              <Field_Binary>
                                  <name>phs_hi_2</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 2 -- high part.
                                      Total integer phase in cycles at (time tag + 0.2 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_2</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 2 -- low part.
                                      Total integer phase in cycles at (time tag + 0.2 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_2</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">61</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 2 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.2 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_3</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 3 -- high part.
                                      Total integer phase in cycles at (time tag + 0.3 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_3</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 3 -- low part.
                                      Total integer phase in cycles at (time tag + 0.3 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_3</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">73</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 3 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.3 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_4</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">77</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 4 -- high part.
                                      Total integer phase in cycles at (time tag + 0.4 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_4</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">81</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 4 -- low part.
                                      Total integer phase in cycles at (time tag + 0.4 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_4</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">85</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 4 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.4 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                            
                              <Field_Binary>
                                  <name>phs_hi_5</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">89</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 5 -- high part.
                                      Total integer phase in cycles at (time tag + 0.5 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_5</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">93</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 5 -- low part.
                                      Total integer phase in cycles at (time tag + 0.5 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_5</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">97</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 5 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.5 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_6</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">101</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 6 -- high part.
                                      Total integer phase in cycles at (time tag + 0.6 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_6</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">105</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 6 -- low part.
                                      Total integer phase in cycles at (time tag + 0.6 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_6</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 6 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.6 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_7</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">113</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 7 -- high part.
                                      Total integer phase in cycles at (time tag + 0.7 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_7</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">117</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 7 -- low part.
                                      Total integer phase in cycles at (time tag + 0.7 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_7</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">121</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 7 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.7 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_8</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">125</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 8 -- high part.
                                      Total integer phase in cycles at (time tag + 0.8 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_8</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">129</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 8 -- low part.
                                      Total integer phase in cycles at (time tag + 0.8 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_8</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">133</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 8 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.8 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_9</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">137</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 9 -- high part.
                                      Total integer phase in cycles at (time tag + 0.9 seconds) divided by 2**32.
                                      Values between 0 and 2*32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_9</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">141</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 9 -- low part.
                                      Total integer phase in cycles at (time tag + 0.9 seconds) modulo 2*32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_9</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">145</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Raw phase sample 9 -- fractional part.
                                      Fractional phase cycles at (time tag + 0.9 seconds) multiplied by 2**32
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>

                              <Field_Binary>
                                  <name>phs_hi_avg</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">149</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>Averaged phase sample  -- high part.  
                                      One second averaged phase, centered around time tag, then divided by 2**32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_lo_avg</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">153</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>Averaged phase sample -- low part.
                                      One second averaged phase, centered around time tag, modulo 2**32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>phs_frac_avg</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">157</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>Averaged phase sample -- fractional part.
                                      One second averaged phase, centered around time tag; fractional part multiplied by 2**32.
                                      Values between 0 and 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_freq</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">161</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Downlink frequency at the time tag.
                                      Values 2.2e9 to 32.3e9 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dop_resid</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">169</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Doppler residual -- negative of the frequency residual.
                                      Values -1.0e6 to 1.0e6 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dop_noise</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">173</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Doppler noise averaged over 10 points in record.
                                      Values 0.0 to 1000.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>slipped_cycles</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">177</field_location>
                                  <data_type>SignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Slipped cycles.
                                      Values -10 to 10 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_loop_type</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">181</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier loop type.
                                      Values 1 to 3 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>snt_flag</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">182</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      SNT measurement flag.
                                         0 = SNT value is the predicted value; 
                                         1 = SNT value is the measured value
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_resid_wt</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">183</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Carrier residual weight. 
                                      The weight value applied to residual phase error in carrier tracking.
                                      When the carrier is suppressed,  carrier weight is 1.0 minus this value.
                                      Values 0.0 to 1.0 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sup_data_id</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">187</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Support data ID.
                                      Name of the frequency predicts set used.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sup_data_rev</name>
                                  <field_number>50</field_number>
                                  <field_location unit="byte">195</field_location>
                                  <data_type>ASCII_String</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Support data revision.
                                      Revision of the frequency predicts set used.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_time_offset</name>
                                  <field_number>51</field_number>
                                  <field_location unit="byte">203</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Predicts time offset.
                                      Seconds added to current time.
                                      Values -8.64e4 to 8.64e4 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_freq_offset</name>
                                  <field_number>52</field_number>
                                  <field_location unit="byte">211</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Predicts frequency offset. 
                                      Hz added to predicted value.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_resid_tol_flag</name>
                                  <field_number>53</field_number>
                                  <field_location unit="byte">219</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier residual tolerance flag.
                                         0 = Out of tolerance; 
                                         1 = In tolerance
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>time_tag_corr_flag</name>
                                  <field_number>54</field_number>
                                  <field_location unit="byte">220</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Time tag correction flag.
                                      Indicates results of validation of the block time tag.
                                         0 = No validation attempted; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>type_time_corr_flag</name>
                                  <field_number>55</field_number>
                                  <field_location unit="byte">221</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Type of time tag correction flag.
                                      Indicates what type of time tag correction was made.
                                         0 = No correction;
                                         1 = Year correction; 
                                         2 = DOY correction; 
                                         3 = Both Year and DOY correction
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dop_mode_corr_flag</name>
                                  <field_number>56</field_number>
                                  <field_location unit="byte">222</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Doppler mode correction flag.
                                      Indicates the results of the validation of the Doppler mode.
                                         0 = Not applicable or no validation attempted; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_stn_corr_flag</name>
                                  <field_number>57</field_number>
                                  <field_location unit="byte">223</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station correction flag.
                                      Indicates the results of the validation of the uplink station.
                                         0 = Not applicable or no validation attempted; 
                                         1 = Validated, no change; 
                                         2 = Validated, changed
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1</name>
                                  <field_number>58</field_number>
                                  <field_location unit="byte">224</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved. One byte.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve8</name>
                                  <field_number>59</field_number>
                                  <field_location unit="byte">225</field_location>
                                  <data_type>UnsignedMSB8</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Reserved. Eight bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>Ramps                             (Data Type 09)</name>
                   <offset unit="byte">7315378</offset>
                   <records>180</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">144</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 132</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>32</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 132 for uplink data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">70</group_length>
                              <Field_Binary>
                                   <name>secondary_chdo_type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Type attribute of the secondary CHDO.  The following values are possible:
                                            132 = uplink data types;
                                            133 = downlink data types;
                                            134 = derived data types;
                                            135 = interferometric data types;
                                            136 = filtered data types.
                                         Set to 132 for this Table.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>secondary_chdo_length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Length attribute of the secondary CHDO.  
                                         Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                         The following values are possible:
                                             66 = uplink data types;
                                            110 = downlink data types;
                                            124 = derived data types;
                                             88 = interferometric data types;
                                             98 = filtered data types.
                                          Set to 66 for this Table.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>orig_id</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Originator ID.
                                         Indicates where this SFDU originated. 
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>last_modifier_id</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Last modifier ID.
                                         Indicates where the contents of this SFDU were last modified. 
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve1a</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Reserved for future expansion of the next field (scft_id).
                                         A value of 0 is expected.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>scft_id</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Spacecraft number.  Values between 1 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>upl_rec_seq_num</name>
                                   <field_number>7</field_number>
                                   <field_location unit="byte">9</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <description>
                                       Uplink record sequence number (UPL RSN).
                                       This is the record sequence number reported by the uplink subsystem (UPL) equipment.
                                         Values between 0 and 2**32-1 are allowed.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>rec_seq_num</name>
                                   <field_number>8</field_number>
                                   <field_location unit="byte">13</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <description>
                                         Record sequence number (RSN).
                                         Begins with zero, then increments by one for each successive uplink tracking 
                                         SFDU of the same data type.  Wraps around from 2**32-1 to zero. Value is reset 
                                         to zero when the data processing system software is restarted.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>year</name>
                                   <field_number>9</field_number>
                                   <field_location unit="byte">17</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Time tag -- year
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>doy</name>
                                   <field_number>10</field_number>
                                   <field_location unit="byte">19</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Time tag -- day of year
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sec</name>
                                   <field_number>11</field_number>
                                   <field_location unit="byte">21</field_location>
                                   <data_type>IEEE754MSBDouble</data_type>
                                   <field_length unit="byte">8</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Time tag -- seconds of day
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rct_day</name>
                                   <field_number>12</field_number>
                                   <field_location unit="byte">29</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>day</unit>
                                   <description>
                                         Record creation time -- days since 1 January 1958.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rct_msec</name>
                                   <field_number>13</field_number>
                                   <field_location unit="byte">31</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <field_format>%10d</field_format>
                                   <unit>millisecond</unit>
                                   <description>
                                         Record creation time -- milliseconds of day
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_dss_id</name>
                                   <field_number>14</field_number>
                                   <field_location unit="byte">35</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink antenna number.  A value between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_band</name>
                                   <field_number>15</field_number>
                                   <field_location unit="byte">36</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink frequency band.
                                            0 = Unknown; 
                                            1 = S-band; 
                                            2 = X-band; 
                                            3 = Ka-band; 
                                            4 = Ku-band; 
                                            5 = L-band
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_assembly_num</name>
                                   <field_number>16</field_number>
                                   <field_location unit="byte">37</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink Assembly Number.
                                         Note that this is to allow for potential future cases where there might be more 
                                         than one uplink of the same band at the same antenna.
                                            0 = Invalid/unknown; 
                                            1 = S- or X-band uplink; 
                                            2 = Ka-band uplink
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_num</name>
                                   <field_number>17</field_number>
                                   <field_location unit="byte">38</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmitter number.  Value depends on transmitter used.  
                                         Values between 0 and 3 are allowed;  0 indicates unknown.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_stat</name>
                                   <field_number>18</field_number>
                                   <field_location unit="byte">39</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmit status.
                                            0 = Not transmitting out the horn; 
                                            1 = Transmitting out the horn; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_mode</name>
                                   <field_number>19</field_number>
                                   <field_location unit="byte">40</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Transmitter mode.
                                            0 = Low power; 
                                            1 = High power; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>cmd_modul_stat</name>
                                   <field_number>20</field_number>
                                   <field_location unit="byte">41</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Command modulation status.
                                            0 = OFF; 
                                            1 = ON; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>rng_modul_stat</name>
                                   <field_number>21</field_number>
                                   <field_location unit="byte">42</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Ranging modulation status.
                                            0 = OFF; 
                                            1 = ON; 
                                            2 = Invalid/unknown
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>fts_vld_flag</name>
                                   <field_number>22</field_number>
                                   <field_location unit="byte">43</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Frequency and Timing (FTS) validity.
                                            0 = Equipment is not synced with FTS; 
                                            1 = Equipment is synced with FTS
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_software_version</name>
                                   <field_number>23</field_number>
                                   <field_location unit="byte">44</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Uplink Software version number.
                                         Gives the version major op code for the uplink software.
                                         Values between 0 and 255 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>transmit_time_tag_delay</name>
                                   <field_number>24</field_number>
                                   <field_location unit="byte">45</field_location>
                                   <data_type>IEEE754MSBDouble</data_type>
                                   <field_length unit="byte">8</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Transmit time tag delay.
                                         Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                         Values 0.0 to 1.0 are allowed.  Value of -1.0 indicates invalid (or not provided).
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>ul_zheight_corr</name>
                                   <field_number>25</field_number>
                                   <field_location unit="byte">53</field_location>
                                   <data_type>IEEE754MSBSingle</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <unit>second</unit>
                                   <description>
                                         Uplink Z-height correction.
                                         Values -1.0 to 1.0 are possible.  Value -99.0 indicates invalid.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>mod_day</name>
                                   <field_number>26</field_number>
                                   <field_location unit="byte">57</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                         Last modification time -- days since 1 January 1958.
                                         Values 0 to 2**16-1 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>mod_msec</name>
                                   <field_number>27</field_number>
                                   <field_location unit="byte">59</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <unit>milliseconds</unit>
                                   <description>
                                         Last modification time -- milliseconds of day.
                                         Values 0 to 86400999 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>version_num</name>
                                   <field_number>28</field_number>
                                   <field_location unit="byte">63</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Version number of the assembly that generated the data. 
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sub_version_num</name>
                                   <field_number>29</field_number>
                                   <field_location unit="byte">64</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Sub-version number of the assembly that generated the data.
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>sub_sub_version_num</name>
                                   <field_number>30</field_number>
                                   <field_location unit="byte">65</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Sub-sub-version number of the assembly that generated the data.
                                         Values 0 to 63 are allowed.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve1b</name>
                                   <field_number>31</field_number>
                                   <field_location unit="byte">66</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <field_format>%1d</field_format>
                                   <description>
                                         Reserved. One byte.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>reserve4a</name>
                                   <field_number>32</field_number>
                                   <field_location unit="byte">67</field_location>
                                   <data_type>UnsignedMSB4</data_type>
                                   <field_length unit="byte">4</field_length>
                                   <field_format>%10d</field_format>
                                   <description>
                                         Reserved. Four bytes.
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Ramp CHDO (Data Type 9)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>10</fields>
                              <groups>0</groups>
                              <description>Ramp CHDO (Data Type 9)</description>
                              <group_location unit="byte">103</group_location>
                              <group_length unit="byte">42</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the ramp data CHDO.
                                      Set to 10 because CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the ramp data CHDO value field. 
                                      Number of bytes after this item.  Set to 38.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_hi_phs_cycles</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Uplink phase at time tag -- high part.
                                      Total integer phase cycles divided by 2**32.
                                      Values from 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_lo_phs_cycles</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Uplink phase at time tag -- low part.
                                      Total integer phase cycles modulo 2**32.
                                      Values from 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_frac_phs_cycles</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Uplink phase at time tag -- fractional part.
                                      Fractional phase cycles multiplied by 2**32.
                                      Values from 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ramp_freq</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Uplink frequency at the time tag.
                                      Values between 2.0e9 and 34.7e9 are allowed; value 0.0 indicates unknown or invalid.
                                      Precision varies with band (phase data give higher precision): 
                                         S-band = 0.5 microhertz; 
                                         X-band = 1.6 microhertz; 
                                         Ka-band = 7.7 microhertz
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ramp_rate</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz/second</unit>
                                  <description>
                                      Rate of change of uplink frequency.
                                      Values -3.2e5 to 3.2e5 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ramp_type</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Ramp type.
                                         0 = Snap; 
                                         1 = Start of new ramp; 
                                         2 = Medial report; 
                                         3 = Periodic report; 
                                         4 = End of ramps; 
                                         5 = Ramping terminated by operator; 
                                         6 = Invalid/unknown; 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fabricated_sfdu_flag</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">34</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Fabricated SFDU Flag -- indicates whether this SFDU was artificially 
                                      fabricated in support of 3-way ranging.
                                         0 = Originally generated by UPL and validated by TTC software; 
                                         1 = Fabricated by TTC software
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve8</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedMSB8</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Reserved. Eight bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>Carrier Observable                (Data Type 16)</name>
                   <offset unit="byte">7341298</offset>
                   <records>191</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">220</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 134</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>55</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 134 for derived data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">128</group_length>
                              <Field_Binary>
                                  <name>secondary_chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the secondary CHDO.  The following values are possible:
                                         132 = uplink data types;
                                         133 = downlink data types;
                                         134 = derived data types;
                                         135 = interferometric data types;
                                         136 = filtered data types.
                                      Set to 134 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>secondary_chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the secondary CHDO.  
                                      Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                      The following values are possible:
                                          66 = uplink data types;
                                         110 = downlink data types;
                                         124 = derived data types;
                                          88 = interferometric data types;
                                          98 = filtered data types.
                                      Set to 124 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>orig_id</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Originator ID. 
                                      Indicates where this SFDU originated. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_modifier_id</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last modifier ID. 
                                      Indicates where the contents of this SFDU were last modified. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved for future expansion of the next field (scft_id).
                                      A value of 0 is expected.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_id</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">8</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft number.  Values between 1 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rec_seq_num</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Record sequence number (RSN).
                                      Begins with zero; increments by one for each successive tracking 
                                      SFDU of the same data type; wraps around from 2**32-1 to zero. 
                                      Value is reset to zero when the data processing system software is restarted.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>year</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Time tag -- year
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>doy</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">15</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Time tag -- day of year.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sec</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Time tag -- seconds of day.
                                      Values 0.00 to 86400.99 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_day</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Record creation time -- days since 1 January 1958.
                                      Values between 0  and 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_msec</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">27</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Record creation time -- milliseconds of day.
                                      Values between 0 and 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>stn_stream_src</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Station stream source. 
                                         1 = UPL/DTT;
                                         2 = non-UPL-DTT: TRK-2-30; 
                                         3 = non-UPL-DTT: TRK-2-20
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">32</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band. 
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_assembly_num</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink Assembly Number.
                                      Note that this is to allow for potential future cases where there 
                                      might be more than one uplink of the same band at the same antenna.
                                         0 = Unknown or not applicable; 
                                         1 = S- or X-band uplink; 
                                         2 = Ka-band uplink
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_num</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">34</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter number. 
                                      Values 1-3 depend on the transmitter used. 
                                      A value of 0 means that the number is unknown or not applicable.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_status</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmit Status.
                                         0 = Not transmitting out the horn; 
                                         1 = Transmitting out the horn; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_mode</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">36</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter mode.
                                         0 = Low power; 
                                         1 = High power; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cmd_modul_stat</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Command modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_modul_stat</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">38</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Ranging modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_time_tag_delay</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">39</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Transmit time tag delay.
                                      Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values between 0.0 and 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_zheight_corr</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Uplink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_dss_id</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink antenna number.
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">52</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved. One byte.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_chan_num</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink channel number.
                                      Values 0 to 24 are allowed; value of 0 implies unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_mode</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">54</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Predicts mode.
                                      Predicts subset used by downlink channel.
                                         0 = No Predicts; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way; 
                                         4 = Unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_prdx_stn</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station used for predicts. Valid only if prdx_mode is 2 or 3 (field 26).
                                      Values 0 to 255 are allowed; a value 0 means that the number is unknown 
                                      or not valid (e.g., no uplink).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band_dl</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">56</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band assumed by downlink.
                                      Uplink band value used by downlink for turn around computations.
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_delay</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Array delay value -- time delay added to path by arraying equipment.  
                                      Obtained from arraying equipment.  Any measurements include this delay.  
                                      Valid only if Array Flag  (array_flag in field 32) is non-zero.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fts_vld_flag</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Frequency and Timing (FTS) validity.
                                        0 = Equipment is not synced with FTS; 
                                        1 = Equipment is synced with FTS
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_lock_stat</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">66</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier lock status.
                                         0 = Off; 
                                         1 = Open (using only predicts); 
                                         2 = Acquiring, FFT Search; 
                                         3 = Acquiring, Waiting for Lock Decision; 
                                         4 = In Lock; 
                                         5 = Out of Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_flag</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">67</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Array flag.
                                         0 = Non-arrayed; 
                                         1 = Arrayed with Full Spectrum Processing subsystem #1; 
                                         2 = Arrayed with Full Spectrum Processing subsystem #2
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_num</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">68</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Number.  
                                      Values 1 to 4 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_time_tag_delay</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Receive time tag delay.  
                                      Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_zheight_corr</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">77</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Downlink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid. 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_ul_stn</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">81</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated uplink station.  
                                      The uplink station per the validation process.  
                                      Values 0 to 255 are allowed; a value 0 means that the antenna is unknown or not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dop_mode</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">82</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated Doppler mode.  
                                         0 = Unknown or not applicable; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_scft_coh</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated spacecraft coherency.  
                                         0 = Unknown or not applicable; 
                                         1 = Coherent; 
                                         2 = Non-coherent; 
                                         3 = Transponded, non-coherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dl_band</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">84</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated downlink frequency band.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band; 
                                         6 = S or X band (26m stations)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_lock</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">85</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder lock status.
                                         0 = Unknown; 
                                         1 = Out-of-lock; 
                                         2 = In Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_num</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">86</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder number.  
                                      Values 0 to 5 are allowed; value 0 indicates the transponder number is unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve2</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">87</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Reserved. Two bytes.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_freq</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">89</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Spacecraft one-way frequency.  
                                      Values 2.0e9 to 32.3e9 are allowed; set to 0.0 if unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_delay</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">97</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Spacecraft transponder delay (coherent ranging delay).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_num</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">105</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- numerator.
                                      Values 0 to 2**32-1 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_den</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- denominator.
                                      Values 0 to 2**32-1 are allowed; a value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_twnc_stat</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">113</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft two-way non-coherent (TWNC) status.
                                         0 = Unknown; 
                                         1 = OFF; 
                                         2 = ON
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_type</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">114</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft oscillator type.
                                         0 = Unknown; 
                                         1 = AUX OSC (auxiliary oscillator); 
                                         2 = USO (ultra-stable oscillator)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_day</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">115</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Last modification time -- days since 1 January 1958.  
                                      Values 0 to 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_msec</name>
                                  <field_number>50</field_number>
                                  <field_location unit="byte">117</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Last modification time -- milliseconds of day.
                                      Values 0 to 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cnt_time</name>
                                  <field_number>51</field_number>
                                  <field_location unit="byte">121</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Integration time of the counts.  
                                      Values 0.0 to 3600.0 are allowed.  A value  0 indicates Not Applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>version_num</name>
                                  <field_number>52</field_number>
                                  <field_location unit="byte">125</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Version number of the assembly that generated the data. 
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_version_num</name>
                                  <field_number>53</field_number>
                                  <field_location unit="byte">126</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-version number of the assembly that generated the data.  
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_sub_version_num</name>
                                  <field_number>54</field_number>
                                  <field_location unit="byte">127</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-sub-version number of the assembly that generated the data.  
                                      Value 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_corr_value</name>
                                  <field_number>55</field_number>
                                  <field_location unit="byte">128</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Correction Value -- indicates results of validation of LNA number.
                                      A value 1 to 4 should be used insterad of lna_num (field 33); a value 0 
                                      indicates no validation or correction was made.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Carrier Frequency Observables CHDO (Data Type 16)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>17</fields>
                              <groups>0</groups>
                              <description>Carrier Frequency Observables CHDO (Data Type 16)</description>
                              <group_location unit="byte">161</group_location>
                              <group_length unit="byte">60</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the Carrier Frequency Observables data CHDO.
                                      Set to 10 because the CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the Carrier Frequency Observables data CHDO value field.
                                      Number of bytes after this item.  Set to 56.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ref_rcv_type</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reference receiver type.
                                         0 = Unknown;
                                         1 = Downlink Telemetry and Tracking Subsystem (DTT); 
                                         2 = MultiFunction Receiver (MFR)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fabricated_ul_flag</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Fabricated uplink flag -- indicates whether this SFDU was created based on 
                                      uplink records fabricated in support of 3-way ranging.
                                         0 = SFDU created using uplink records originally generated by UPL and validated by TTC software; 
                                         1 = SFDU created using uplink records fabricated by TTC software 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_prefit_resid_tol_value</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Received carrier pre-fit residual tolerance value (provided by customer).
                                      Value used for setting received carrier pre-fit residual tolerance flag.  
                                      Values -1.0e6 to 1.0e6 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve2</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">11</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Reserved. Two bytes.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dop_noise</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Doppler noise. 
                                      Values 0.0 to 1000.0 allowed; value -1.0 indicates invalid.</description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>delta_ff</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Change in downlink frequency since the last sample divided by the current downlink frequency.
                                      Valid only for UPL-DTT antennas.
                                      Values -1.0 to 1.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_sig_lvl</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dBm</unit>
                                  <description>
                                      Received signal level.  
                                      Carrier power (or data power, if suppressed carrier tracking).
                                      Values -190.0 to -45.0 allowed; value -300.0 indicates not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>num_obs</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Number of Observable measurements.
                                      Set to 1.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>obs_cnt_time</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Observable count time.  Integration time of the observables.
                                      Values 0.1 to 3600.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_carr_obs</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Received Carrier observable.  The negative of the difference in the downlink
                                      carrier phase at the measurement time tag and the downlink carrier phase at  
                                      the start of the interval divided by the interval time. 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_prefit_resid</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">43</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Received carrier pre-fit residual (observed minus predicted).
                                      Values -1.0e6 to 1.0e6 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_prefit_resid_vld_flag</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Received carrier pre-fit residual validity indicator.
                                         0 = Invalid pre-fit residual data; 
                                         1 = Valid pre-fit residual data
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_prefit_resid_tol_flag</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">48</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Received carrier pre-fit residual tolerance flag.
                                         0 = Out of tolerance; 
                                         1 = In tolerance; 
                                         2 = Not applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_resid_wt</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">49</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Carrier residual weight.  The weight value applied to residual phase error in carrier 
                                      tracking (weight is 1.0 minus this value in suppressed carrier tracking).
                                      Values 0.0 to 1.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve8</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedMSB8</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Reserved. Eight bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
             <Table_Binary>
                   <name>Total Phase                       (Data Type 17)</name>
                   <offset unit="byte">7383318</offset>
                   <records>191</records>
                   <description>
                       Raw radio tracking data.
                   </description>
                   <Record_Binary>
                         <fields>0</fields>
                         <groups>5</groups>
                         <record_length unit="byte">236</record_length>
                       <Group_Field_Binary>
                              <name>SFDU Label</name>
                              <group_number>1</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The SFDU label</description>
                              <group_location unit="byte">1</group_location>
                              <group_length unit="byte">20</group_length>
                              <Field_Binary>
                                    <name>SFDU Control Authority</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Control Authority for this data
                                          type.  Set to "NJPL", meaning the data description information for
                                          this type of SFDU is maintained by the NASA/JPL Control Authority.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Label Version ID</name>
                                    <field_number>2</field_number>
                                    <field_location unit="byte">5</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Label Version Identifier.
                                          Set to "2", meaning the length given in field 6 is formatted
                                          as a binary unsigned integer.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Class ID</name>
                                    <field_number>3</field_number>
                                    <field_location unit="byte">6</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">1</field_length>
                                    <description>
                                          An ASCII character giving the SFDU Class Identifier.  Set to "I",
                                          meaning this is a Compressed Header Data Object (CHDO) structured SFDU.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Reserved</name>
                                    <field_number>4</field_number>
                                    <field_location unit="byte">7</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                          These two bytes are not defined.
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Data Description ID</name>
                                    <field_number>5</field_number>
                                    <field_location unit="byte">9</field_location>
                                    <data_type>ASCII_String</data_type>
                                    <field_length unit="byte">4</field_length>
                                    <description>
                                          An ASCII string giving the SFDU Data Description Identifier.
                                          Possible values are:
                                             C123 = Uplink data types
                                             C124 = Downlink data types
                                             C125 = Derived data types
                                             C126 = Interferometric data types
                                             C127 = Filtered data types
                                    </description>
                              </Field_Binary>
                              <Field_Binary>
                                    <name>SFDU Length</name>
                                    <field_number>6</field_number>
                                    <field_location unit="byte">13</field_location>
                                    <data_type>UnsignedMSB8</data_type>
                                    <field_length unit="byte">8</field_length>
                                    <unit>byte</unit>
                                    <description>
                                          The number of remaining bytes in the SFDU after the 20-byte SFDU label.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Aggregation CHDO Label</name>
                              <group_number>2</group_number>
                              <repetitions>1</repetitions>
                              <fields>2</fields>
                              <groups>0</groups>
                              <description>The Aggregation CHDO Label</description>
                              <group_location unit="byte">21</group_location>
                              <group_length unit="byte">4</group_length>
                              <Field_Binary>
                                   <name>Header Aggregation CHDO Type</name>
                                   <field_number>1</field_number>
                                   <field_location unit="byte">1</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <description>
                                        Header Aggregation CHDO Type.  Set to "1", meaning this CHDO is an
                                        aggregation of header CHDOs.  The NJPL Control Authority maintains a
                                        registry of CHDO types.
                                   </description>
                              </Field_Binary>
                             <Field_Binary>
                                   <name>Header Aggregation CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                        Header Aggregation CHDO Length.
                                    </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Primary CHDO</name>
                              <group_number>3</group_number>
                              <repetitions>1</repetitions>
                              <fields>6</fields>
                              <groups>0</groups>
                              <description>The Primary CHDO</description>
                              <group_location unit="byte">25</group_location>
                              <group_length unit="byte">8</group_length>
                              <Field_Binary>
                                    <name>Primary Header CHDO Type</name>
                                    <field_number>1</field_number>
                                    <field_location unit="byte">1</field_location>
                                    <data_type>UnsignedMSB2</data_type>
                                    <field_length unit="byte">2</field_length>
                                    <description>
                                         Primary Header CHDO Type.  Set to to 2, meaning this CHDO is a
                                         primary header CHDO.  The NJPL Control Authority maintains a
                                         registry of CHDO types.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Primary Header CHDO Length</name>
                                   <field_number>2</field_number>
                                   <field_location unit="byte">3</field_location>
                                   <data_type>UnsignedMSB2</data_type>
                                   <field_length unit="byte">2</field_length>
                                   <unit>byte</unit>
                                   <description>
                                      Primary Header CHDO Length. Set to 4, meaning length of the value
                                      field of the Primary Header CHDO is 4 bytes.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Major Data Class</name>
                                   <field_number>3</field_number>
                                   <field_location unit="byte">5</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Major Data Class.  Set to 6, meaning these are ground station monitor data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Minor Data Class</name>
                                   <field_number>4</field_number>
                                   <field_location unit="byte">6</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Minor Data Class.  Set to 14 meaning these are processed tracking data.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Mission Identifier</name>
                                   <field_number>5</field_number>
                                   <field_location unit="byte">7</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Mission Identifier.  Set to a number between 0 and 255.
                                   </description>
                             </Field_Binary>
                             <Field_Binary>
                                   <name>Format Code</name>
                                   <field_number>6</field_number>
                                   <field_location unit="byte">8</field_location>
                                   <data_type>UnsignedByte</data_type>
                                   <field_length unit="byte">1</field_length>
                                   <description>
                                         Format Code; also known as the data type.
                                         The following data types (DT) are possible:
                                            0 = Uplink Carrier Phase;
                                            1 = Downlink Carrier Phase; 
                                            2 = Uplink Sequential Ranging Phase; 
                                            3 = Downlink Sequential Ranging Phase; 
                                            4 = Uplink PN Ranging Phase;   
                                            5 = Downlink PN Ranging Phase;   
                                            6 = Doppler;   
                                            7 = Sequential Ranging;   
                                            8 = Angles;   
                                            9 = Ramps;
                                            10 = VLBI; 
                                            11 = DRVID; 
                                            12 = Smoothed Noise; 
                                            13 = Allan Deviation; 
                                            14 = PN Ranging; 
                                            15 = Tone Ranging; 
                                            16 = Carrier Observable; 
                                            17 = Total Phase Observable
                                   </description>
                             </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Secondary CHDO 134</name>
                              <group_number>4</group_number>
                              <repetitions>1</repetitions>
                              <fields>55</fields>
                              <groups>0</groups>
                              <description>Secondary CHDO 134 for derived data types</description>
                              <group_location unit="byte">33</group_location>
                              <group_length unit="byte">128</group_length>
                              <Field_Binary>
                                  <name>secondary_chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the secondary CHDO.  The following values are possible:
                                         132 = uplink data types;
                                         133 = downlink data types;
                                         134 = derived data types;
                                         135 = interferometric data types;
                                         136 = filtered data types.
                                      Set to 134 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>secondary_chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the secondary CHDO.  
                                      Indicates the length of the value field (bytes after this item) of the secondary CHDO.
                                      The following values are possible:
                                          66 = uplink data types;
                                         110 = downlink data types;
                                         124 = derived data types;
                                          88 = interferometric data types;
                                          98 = filtered data types.
                                      Set to 124 for this Table.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>orig_id</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Originator ID. 
                                      Indicates where this SFDU originated. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>last_modifier_id</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Last modifier ID. 
                                      Indicates where the contents of this SFDU were last modified. 
                                      Values between 0 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved for future expansion of the next field (scft_id).
                                      A value of 0 is expected.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_id</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">8</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft number.  Values between 1 and 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rec_seq_num</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">9</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Record sequence number (RSN).
                                      Begins with zero; increments by one for each successive tracking 
                                      SFDU of the same data type; wraps around from 2**32-1 to zero. 
                                      Value is reset to zero when the data processing system software is restarted.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>year</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Time tag -- year
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>doy</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">15</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Time tag -- day of year.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sec</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Time tag -- seconds of day.
                                      Values 0.00 to 86400.99 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_day</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Record creation time -- days since 1 January 1958.
                                      Values between 0  and 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rct_msec</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">27</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Record creation time -- milliseconds of day.
                                      Values between 0 and 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>stn_stream_src</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Station stream source. 
                                         1 = UPL/DTT;
                                         2 = non-UPL-DTT: TRK-2-30; 
                                         3 = non-UPL-DTT: TRK-2-20
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">32</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band. 
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_assembly_num</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">33</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink Assembly Number.
                                      Note that this is to allow for potential future cases where there 
                                      might be more than one uplink of the same band at the same antenna.
                                         0 = Unknown or not applicable; 
                                         1 = S- or X-band uplink; 
                                         2 = Ka-band uplink
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_num</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">34</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter number. 
                                      Values 1-3 depend on the transmitter used. 
                                      A value of 0 means that the number is unknown or not applicable.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_status</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmit Status.
                                         0 = Not transmitting out the horn; 
                                         1 = Transmitting out the horn; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_mode</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">36</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Transmitter mode.
                                         0 = Low power; 
                                         1 = High power; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cmd_modul_stat</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Command modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rng_modul_stat</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">38</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Ranging modulation status.
                                         0 = OFF; 
                                         1 = ON; 
                                         2 = Invalid or unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>transmit_time_tag_delay</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">39</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Transmit time tag delay.
                                      Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values between 0.0 and 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_zheight_corr</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Uplink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_dss_id</name>
                                  <field_number>23</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink antenna number.
                                      Values 0 to 255 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve1a</name>
                                  <field_number>24</field_number>
                                  <field_location unit="byte">52</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reserved. One byte.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_chan_num</name>
                                  <field_number>25</field_number>
                                  <field_location unit="byte">53</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Downlink channel number.
                                      Values 0 to 24 are allowed; value of 0 implies unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>prdx_mode</name>
                                  <field_number>26</field_number>
                                  <field_location unit="byte">54</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Predicts mode.
                                      Predicts subset used by downlink channel.
                                         0 = No Predicts; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way; 
                                         4 = Unknown
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_prdx_stn</name>
                                  <field_number>27</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink station used for predicts. Valid only if prdx_mode is 2 or 3 (field 26).
                                      Values 0 to 255 are allowed; a value 0 means that the number is unknown 
                                      or not valid (e.g., no uplink).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ul_band_dl</name>
                                  <field_number>28</field_number>
                                  <field_location unit="byte">56</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Uplink frequency band assumed by downlink.
                                      Uplink band value used by downlink for turn around computations.
                                         0 = Unknown or not applicable; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_delay</name>
                                  <field_number>29</field_number>
                                  <field_location unit="byte">57</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Array delay value -- time delay added to path by arraying equipment.  
                                      Obtained from arraying equipment.  Any measurements include this delay.  
                                      Valid only if Array Flag  (array_flag in field 32) is non-zero.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fts_vld_flag</name>
                                  <field_number>30</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Frequency and Timing (FTS) validity.
                                        0 = Equipment is not synced with FTS; 
                                        1 = Equipment is synced with FTS
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_lock_stat</name>
                                  <field_number>31</field_number>
                                  <field_location unit="byte">66</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Carrier lock status.
                                         0 = Off; 
                                         1 = Open (using only predicts); 
                                         2 = Acquiring, FFT Search; 
                                         3 = Acquiring, Waiting for Lock Decision; 
                                         4 = In Lock; 
                                         5 = Out of Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>array_flag</name>
                                  <field_number>32</field_number>
                                  <field_location unit="byte">67</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Array flag.
                                         0 = Non-arrayed; 
                                         1 = Arrayed with Full Spectrum Processing subsystem #1; 
                                         2 = Arrayed with Full Spectrum Processing subsystem #2
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_num</name>
                                  <field_number>33</field_number>
                                  <field_location unit="byte">68</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Number.  
                                      Values 1 to 4 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_time_tag_delay</name>
                                  <field_number>34</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Receive time tag delay.  
                                      Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid (or not provided).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dl_zheight_corr</name>
                                  <field_number>35</field_number>
                                  <field_location unit="byte">77</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Downlink Z-height correction.
                                      Values -1.0 to 1.0 are allowed; a value -99.0 indicates invalid. 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_ul_stn</name>
                                  <field_number>36</field_number>
                                  <field_location unit="byte">81</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated uplink station.  
                                      The uplink station per the validation process.  
                                      Values 0 to 255 are allowed; a value 0 means that the antenna is unknown or not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dop_mode</name>
                                  <field_number>37</field_number>
                                  <field_location unit="byte">82</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated Doppler mode.  
                                         0 = Unknown or not applicable; 
                                         1 = One-way; 
                                         2 = Two-way; 
                                         3 = Three-way
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_scft_coh</name>
                                  <field_number>38</field_number>
                                  <field_location unit="byte">83</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated spacecraft coherency.  
                                         0 = Unknown or not applicable; 
                                         1 = Coherent; 
                                         2 = Non-coherent; 
                                         3 = Transponded, non-coherent
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>vld_dl_band</name>
                                  <field_number>39</field_number>
                                  <field_location unit="byte">84</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Validated downlink frequency band.
                                         0 = Unknown; 
                                         1 = S-band; 
                                         2 = X-band; 
                                         3 = Ka-band; 
                                         4 = Ku-band; 
                                         5 = L-band; 
                                         6 = S or X band (26m stations)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_lock</name>
                                  <field_number>40</field_number>
                                  <field_location unit="byte">85</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder lock status.
                                         0 = Unknown; 
                                         1 = Out-of-lock; 
                                         2 = In Lock
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_num</name>
                                  <field_number>41</field_number>
                                  <field_location unit="byte">86</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft transponder number.  
                                      Values 0 to 5 are allowed; value 0 indicates the transponder number is unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve2</name>
                                  <field_number>42</field_number>
                                  <field_location unit="byte">87</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Reserved. Two bytes.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_freq</name>
                                  <field_number>43</field_number>
                                  <field_location unit="byte">89</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Spacecraft one-way frequency.  
                                      Values 2.0e9 to 32.3e9 are allowed; set to 0.0 if unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_delay</name>
                                  <field_number>44</field_number>
                                  <field_location unit="byte">97</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Spacecraft transponder delay (coherent ranging delay).  
                                      Values 0.0 to 1.0 are allowed; a value -1.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_num</name>
                                  <field_number>45</field_number>
                                  <field_location unit="byte">105</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- numerator.
                                      Values 0 to 2**32-1 are allowed; a value  0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_transpd_turn_den</name>
                                  <field_number>46</field_number>
                                  <field_location unit="byte">109</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Spacecraft transponder turn around ratio -- denominator.
                                      Values 0 to 2**32-1 are allowed; a value 0 indicates unknown.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_twnc_stat</name>
                                  <field_number>47</field_number>
                                  <field_location unit="byte">113</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft two-way non-coherent (TWNC) status.
                                         0 = Unknown; 
                                         1 = OFF; 
                                         2 = ON
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>scft_osc_type</name>
                                  <field_number>48</field_number>
                                  <field_location unit="byte">114</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Spacecraft oscillator type.
                                         0 = Unknown; 
                                         1 = AUX OSC (auxiliary oscillator); 
                                         2 = USO (ultra-stable oscillator)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_day</name>
                                  <field_number>49</field_number>
                                  <field_location unit="byte">115</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Last modification time -- days since 1 January 1958.  
                                      Values 0 to 2**16-1 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>mod_msec</name>
                                  <field_number>50</field_number>
                                  <field_location unit="byte">117</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>millisecond</unit>
                                  <description>
                                      Last modification time -- milliseconds of day.
                                      Values 0 to 86400999 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>cnt_time</name>
                                  <field_number>51</field_number>
                                  <field_location unit="byte">121</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Integration time of the counts.  
                                      Values 0.0 to 3600.0 are allowed.  A value  0 indicates Not Applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>version_num</name>
                                  <field_number>52</field_number>
                                  <field_location unit="byte">125</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Version number of the assembly that generated the data. 
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_version_num</name>
                                  <field_number>53</field_number>
                                  <field_location unit="byte">126</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-version number of the assembly that generated the data.  
                                      Values 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>sub_sub_version_num</name>
                                  <field_number>54</field_number>
                                  <field_location unit="byte">127</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Sub-sub-version number of the assembly that generated the data.  
                                      Value 0 to 63 are allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>lna_corr_value</name>
                                  <field_number>55</field_number>
                                  <field_location unit="byte">128</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      LNA Correction Value -- indicates results of validation of LNA number.
                                      A value 1 to 4 should be used insterad of lna_num (field 33); a value 0 
                                      indicates no validation or correction was made.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                        <Group_Field_Binary>
                              <name>Total Count Phase Observable CHDO (Data Type 17)</name>
                              <group_number>5</group_number>
                              <repetitions>1</repetitions>
                              <fields>22</fields>
                              <groups>0</groups>
                              <description>Total Count Phase Observable CHDO (Data Type 17)</description>
                              <group_location unit="byte">161</group_location>
                              <group_length unit="byte">76</group_length>
                              <Field_Binary>
                                  <name>chdo_type</name>
                                  <field_number>1</field_number>
                                  <field_location unit="byte">1</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Type attribute of the Total Count Phase Observables data CHDO.
                                      Set to 10 because the CHDO contains binary data.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>chdo_length</name>
                                  <field_number>2</field_number>
                                  <field_location unit="byte">3</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Length attribute of the Total Count Phase Observables data CHDO value field.
                                      Number of bytes after this item.  Set to 72.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>ref_rcv_type</name>
                                  <field_number>3</field_number>
                                  <field_location unit="byte">5</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Reference receiver type.
                                         0 = Unknown;
                                         1 = Downlink Telemetry and Tracking Subsystem (DTT); 
                                         2 = MultiFunction Receiver (MFR)
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>fabricated_ul_flag</name>
                                  <field_number>4</field_number>
                                  <field_location unit="byte">6</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Fabricated uplink flag -- indicates whether this SFDU was created based on 
                                      uplink records fabricated in support of 3-way ranging.
                                         0 = SFDU created using uplink records originally generated by UPL and validated by TTC software; 
                                         1 = SFDU created using uplink records fabricated by TTC software 
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_prefit_resid_tol_value</name>
                                  <field_number>5</field_number>
                                  <field_location unit="byte">7</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Total Count Phase pre-fit residual tolerance value (provided by customer).
                                      Value used for setting total count phase pre-fit residual tolerance flag. 
                                      Values -1.0e6 to 1.0e6 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve2</name>
                                  <field_number>6</field_number>
                                  <field_location unit="byte">11</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Reserved. Two bytes.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>dop_noise</name>
                                  <field_number>7</field_number>
                                  <field_location unit="byte">13</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>hertz</unit>
                                  <description>
                                      Doppler noise. 
                                      Values 0.0 to 1000.0 allowed; value -1.0 indicates invalid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>delta_ff</name>
                                  <field_number>8</field_number>
                                  <field_location unit="byte">17</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Change in downlink frequency since the last sample divided by the current downlink frequency.
                                      Valid only for UPL-DTT antennas.
                                      Values -1.0 to 1.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>rcv_sig_lvl</name>
                                  <field_number>9</field_number>
                                  <field_location unit="byte">25</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <unit>dBm</unit>
                                  <description>
                                      Received signal level.  
                                      Carrier power (or data power, if suppressed carrier tracking).
                                      Values -190.0 to -45.0 allowed; value -300.0 indicates not valid.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>num_obs</name>
                                  <field_number>10</field_number>
                                  <field_location unit="byte">29</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Number of Observable measurements.
                                      Set to 1.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>obs_cnt_time</name>
                                  <field_number>11</field_number>
                                  <field_location unit="byte">31</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Observable count time. Integration time of the observables.
                                      Values 0.1 to 3600.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_st_year</name>
                                  <field_number>12</field_number>
                                  <field_location unit="byte">35</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <description>
                                      Total Count Phase observable start time -- year.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_st_doy</name>
                                  <field_number>13</field_number>
                                  <field_location unit="byte">37</field_location>
                                  <data_type>UnsignedMSB2</data_type>
                                  <field_length unit="byte">2</field_length>
                                  <unit>day</unit>
                                  <description>
                                      Total Count Phase observable start time -- day of year.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_st_sec</name>
                                  <field_number>14</field_number>
                                  <field_location unit="byte">39</field_location>
                                  <data_type>IEEE754MSBDouble</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <unit>second</unit>
                                  <description>
                                      Total Count Phase observable start time -- second.
                                      Values 0.00 to 86400.999 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_obs_hi</name>
                                  <field_number>15</field_number>
                                  <field_location unit="byte">47</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Negative of Total Count Phase observable - high part  
                                      Total integer phase cycles divided by 2**32.
                                      Values 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_obs_lo</name>
                                  <field_number>16</field_number>
                                  <field_location unit="byte">51</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Negative of Total Count Phase observable - low part  
                                      Total integer phase cycles modulo 2**32.
                                      Values 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_obs_frac</name>
                                  <field_number>17</field_number>
                                  <field_location unit="byte">55</field_location>
                                  <data_type>UnsignedMSB4</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Negative of Total Count Phase observable - fractional part  
                                      Fractional phase cycles multiplied by 2**32.
                                      Values 0 to 2**32-1 are allowed.
                                      Total phase is HI*2**32 + LO + FRAC/2**32.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_prefit_resid</name>
                                  <field_number>18</field_number>
                                  <field_location unit="byte">59</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Total Count Phase pre-fit residual (observed minus predicted).
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_prefit_resid_vld_flag</name>
                                  <field_number>19</field_number>
                                  <field_location unit="byte">63</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Total Count Phase pre-fit residual validity indicator.
                                         0 = Invalid pre-fit residual data; 
                                         1 = Valid pre-fit residual data
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>total_cnt_phs_prefit_resid_tol_flag</name>
                                  <field_number>20</field_number>
                                  <field_location unit="byte">64</field_location>
                                  <data_type>UnsignedByte</data_type>
                                  <field_length unit="byte">1</field_length>
                                  <description>
                                      Total Count Phase pre-fit residual tolerance flag.
                                         0 = Out of tolerance; 
                                         1 = In tolerance; 
                                         2 = Not applicable
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>carr_resid_wt</name>
                                  <field_number>21</field_number>
                                  <field_location unit="byte">65</field_location>
                                  <data_type>IEEE754MSBSingle</data_type>
                                  <field_length unit="byte">4</field_length>
                                  <description>
                                      Carrier residual weight.  The weight value applied to residual phase error in carrier 
                                      tracking (weight is 1.0 minus this value in suppressed carrier tracking).
                                      Values 0.0 to 1.0 allowed.
                                  </description>
                              </Field_Binary>
                              <Field_Binary>
                                  <name>reserve8</name>
                                  <field_number>22</field_number>
                                  <field_location unit="byte">69</field_location>
                                  <data_type>UnsignedMSB8</data_type>
                                  <field_length unit="byte">8</field_length>
                                  <description>
                                      Reserved. Eight bytes.
                                  </description>
                              </Field_Binary>
                        </Group_Field_Binary>
                   </Record_Binary>
             </Table_Binary>
      </File_Area_Observational>
</Product_Observational>
