This is a logfile for the mex measurement on 242 Times are given in the format YYYYMMDDhhmm OCC Measurement time: 200808290503 - 200808290525 Checking files of DOY 242 -------------------------------------------------- -------------------------------------------------- ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 D1-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2008_242_OP_D1_050036_0000 Wrong sample time for this file 1. The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 AGC1-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2008_242_OP_G1_050036_0000 Wrong sample time for this file 1. The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting CL D1-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2008_242_CL_D1_002745_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 D2-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2008_242_OP_D2_050036_0000 The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 AGC2-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2008_242_OP_G2_050036_0000 Wrong sample time for this file 0. The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting CL D2-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2008_242_CL_D2_002745_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 MET-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2008_242_OP_ME_003856_0004 The files cover the following time range 200808290438 - 200808290529 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 D1-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2008_242_OP_D1_050037_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D1_050037_0000 NN12_MEX1_2008_242_OP_D1_050037_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D1_050037_0001 NN12_MEX1_2008_242_OP_D1_050037_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D1_050037_0002 NN12_MEX1_2008_242_OP_D1_050037_0003 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D1_050037_0003 NN12_MEX1_2008_242_OP_D1_050037_0004 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D1_050037_0004 The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 AGC1-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2008_242_OP_G1_050037_0000 Wrong sample time for this file 1. The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 D2-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2008_242_OP_D2_050037_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D2_050037_0000 NN12_MEX1_2008_242_OP_D2_050037_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D2_050037_0001 NN12_MEX1_2008_242_OP_D2_050037_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D2_050037_0002 NN12_MEX1_2008_242_OP_D2_050037_0003 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D2_050037_0003 NN12_MEX1_2008_242_OP_D2_050037_0004 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D2_050037_0004 The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 AGC2-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2008_242_OP_G2_050037_0000 Wrong sample time for this file 1. The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 MET-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2008_242_OP_ME_003857_0004 The files cover the following time range 200808290439 - 200808290529 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 D1-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2008_242_OP_D1_050038_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D1_050038_0000 NN13_MEX1_2008_242_OP_D1_050038_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D1_050038_0001 NN13_MEX1_2008_242_OP_D1_050038_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D1_050038_0002 NN13_MEX1_2008_242_OP_D1_050038_0003 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D1_050038_0003 NN13_MEX1_2008_242_OP_D1_050038_0004 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D1_050038_0004 The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 AGC1-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2008_242_OP_G1_050038_0000 Wrong sample time for this file 1. The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 D2-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2008_242_OP_D2_050038_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D2_050038_0000 NN13_MEX1_2008_242_OP_D2_050038_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D2_050038_0001 NN13_MEX1_2008_242_OP_D2_050038_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D2_050038_0002 NN13_MEX1_2008_242_OP_D2_050038_0003 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D2_050038_0003 NN13_MEX1_2008_242_OP_D2_050038_0004 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D2_050038_0004 The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 AGC2-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2008_242_OP_G2_050038_0000 Wrong sample time for this file 1. The files cover the following time range 200808290500 - 200808290525 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 MET-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2008_242_OP_ME_003857_0004 The files cover the following time range 200808290439 - 200808290529 ++++++++++++++++++++++++++++++++++++ The following files are missing: ++++++++++++++++++++++++++++++++++++ Wrong sample time for this file 1. Wrong sample time for this file 1. Wrong sample time for this file 0. Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D1_050037_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D1_050037_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D1_050037_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D1_050037_0003 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D1_050037_0004 Wrong sample time for this file 1. Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D2_050037_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D2_050037_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D2_050037_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D2_050037_0003 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2008_242_OP_D2_050037_0004 Wrong sample time for this file 1. Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D1_050038_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D1_050038_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D1_050038_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D1_050038_0003 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D1_050038_0004 Wrong sample time for this file 1. Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D2_050038_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D2_050038_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D2_050038_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D2_050038_0003 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2008_242_OP_D2_050038_0004 Wrong sample time for this file 1. ++++++++++++++++++++++++++++++++++++ Please note! For open loop measurements IFMS had a special configuration: IFMS NN12 and NN13 D1 were used for open loop Consequently, IFMS NN12 and NN13 Doppler 1 and IFMS NN12 and NN13 AGC2 files should be missing THIS IS NOT A MISTAKE ++++++++++++++++++++++++++++++++++++