This is a logfile for the mex measurement on 032 Times are given in the format YYYYMMDDhhmm OCC Measurement time: 200902010100 - 200902010122 Checking files of DOY 032 -------------------------------------------------- -------------------------------------------------- ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 D1-files ++++++++++++++++++++++++++++++++++++ Could not find any files that cover measurement ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 AGC1-files ++++++++++++++++++++++++++++++++++++ Could not find any files that cover measurement ++++++++++++++++++++++++++++++++++++ Sorting CL D1-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2009_032_CL_D1_200755_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 D2-files ++++++++++++++++++++++++++++++++++++ Could not find any files that cover measurement ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 AGC2-files ++++++++++++++++++++++++++++++++++++ Could not find any files that cover measurement ++++++++++++++++++++++++++++++++++++ Sorting CL D2-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2009_032_CL_D2_200755_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 MET-files ++++++++++++++++++++++++++++++++++++ Could not find any files that cover measurement ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 D1-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2009_032_OP_D1_005709_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D1_005709_0000 NN12_MEX1_2009_032_OP_D1_005709_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D1_005709_0001 NN12_MEX1_2009_032_OP_D1_005709_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D1_005709_0002 NN12_MEX1_2009_032_OP_D1_005709_0003 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D1_005709_0003 Files stop too early at 200902010119 instead of 200902010122 The files cover the following time range 200902010057 - 200902010119 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 AGC1-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2009_032_OP_G1_005709_0000 Wrong sample time for this file 1. Files stop too early at 200902010119 instead of 200902010122 The files cover the following time range 200902010057 - 200902010119 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 D2-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2009_032_OP_D2_005709_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D2_005709_0000 NN12_MEX1_2009_032_OP_D2_005709_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D2_005709_0001 NN12_MEX1_2009_032_OP_D2_005709_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D2_005709_0002 NN12_MEX1_2009_032_OP_D2_005709_0003 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D2_005709_0003 Files stop too early at 200902010119 instead of 200902010122 The files cover the following time range 200902010057 - 200902010119 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 AGC2-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2009_032_OP_G2_005709_0000 Wrong sample time for this file 1. Files stop too early at 200902010119 instead of 200902010122 The files cover the following time range 200902010057 - 200902010119 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 MET-files ++++++++++++++++++++++++++++++++++++ Could not find any files that cover measurement ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 D1-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2009_032_OP_D1_005710_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D1_005710_0000 NN13_MEX1_2009_032_OP_D1_005710_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D1_005710_0001 NN13_MEX1_2009_032_OP_D1_005710_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D1_005710_0002 NN13_MEX1_2009_032_OP_D1_005710_0003 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D1_005710_0003 Files stop too early at 200902010119 instead of 200902010122 The files cover the following time range 200902010057 - 200902010119 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 AGC1-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2009_032_OP_G1_005710_0000 Wrong sample time for this file 1. Files stop too early at 200902010119 instead of 200902010122 The files cover the following time range 200902010057 - 200902010119 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 D2-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2009_032_OP_D2_005710_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D2_005710_0000 NN13_MEX1_2009_032_OP_D2_005710_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D2_005710_0001 NN13_MEX1_2009_032_OP_D2_005710_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D2_005710_0002 NN13_MEX1_2009_032_OP_D2_005710_0003 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D2_005710_0003 Files stop too early at 200902010119 instead of 200902010122 The files cover the following time range 200902010057 - 200902010119 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 AGC2-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2009_032_OP_G2_005710_0000 Wrong sample time for this file 1. Files stop too early at 200902010119 instead of 200902010122 The files cover the following time range 200902010057 - 200902010119 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 MET-files ++++++++++++++++++++++++++++++++++++ Could not find any files that cover measurement ++++++++++++++++++++++++++++++++++++ The following files are missing: ++++++++++++++++++++++++++++++++++++ Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D1_005709_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D1_005709_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D1_005709_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D1_005709_0003 Wrong sample time for this file 1. Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D2_005709_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D2_005709_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D2_005709_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_032_OP_D2_005709_0003 Wrong sample time for this file 1. Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D1_005710_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D1_005710_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D1_005710_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D1_005710_0003 Wrong sample time for this file 1. Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D2_005710_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D2_005710_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D2_005710_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_032_OP_D2_005710_0003 Wrong sample time for this file 1. ++++++++++++++++++++++++++++++++++++ Please note! For open loop measurements IFMS had a special configuration: IFMS NN12 and NN13 D1 were used for open loop Consequently, IFMS NN12 and NN13 Doppler 1 and IFMS NN12 and NN13 AGC2 files should be missing THIS IS NOT A MISTAKE ++++++++++++++++++++++++++++++++++++