This is a logfile for the mex measurement on 264 Times are given in the format YYYYMMDDhhmm OCC Measurement time: 200909212308 - 200909212330 Checking files of DOY 264 -------------------------------------------------- -------------------------------------------------- ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 D1-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2009_264_OP_D1_220136_0001 Wrong sample time for this file 1. Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212301 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 AGC1-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2009_264_OP_G1_213705_0001 Wrong sample time for this file 1. Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212237 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting CL D1-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2009_264_CL_D1_210746_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 D2-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2009_264_OP_D2_220136_0001 Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212301 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 AGC2-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2009_264_OP_G2_213705_0001 Wrong sample time for this file 0. Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212237 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting CL D2-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2009_264_CL_D2_210746_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 MET-files ++++++++++++++++++++++++++++++++++++ NN11_MEX1_2009_264_OP_ME_211848_0001 NN11_MEX1_2009_264_OP_ME_211848_0002 The files cover the following time range 200909212218 - 200909220017 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 D1-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2009_264_OP_D1_230552_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D1_230552_0000 NN12_MEX1_2009_264_OP_D1_230552_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D1_230552_0001 NN12_MEX1_2009_264_OP_D1_230552_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D1_230552_0002 NN12_MEX1_2009_264_OP_D1_230552_0003 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D1_230552_0003 NN12_MEX1_2009_264_OP_D1_230552_0004 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D1_230552_0004 Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212305 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 AGC1-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2009_264_OP_G1_230552_0000 Wrong sample time for this file 1. Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212305 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 D2-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2009_264_OP_D2_230552_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D2_230552_0000 NN12_MEX1_2009_264_OP_D2_230552_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D2_230552_0001 NN12_MEX1_2009_264_OP_D2_230552_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D2_230552_0002 NN12_MEX1_2009_264_OP_D2_230552_0003 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D2_230552_0003 NN12_MEX1_2009_264_OP_D2_230552_0004 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D2_230552_0004 Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212305 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 AGC2-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2009_264_OP_G2_230552_0000 Wrong sample time for this file 1. Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212305 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 MET-files ++++++++++++++++++++++++++++++++++++ NN12_MEX1_2009_264_OP_ME_211848_0001 NN12_MEX1_2009_264_OP_ME_211848_0002 The files cover the following time range 200909212219 - 200909220018 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 D1-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2009_264_OP_D1_230553_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D1_230553_0000 NN13_MEX1_2009_264_OP_D1_230553_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D1_230553_0001 NN13_MEX1_2009_264_OP_D1_230553_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D1_230553_0002 NN13_MEX1_2009_264_OP_D1_230553_0003 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D1_230553_0003 NN13_MEX1_2009_264_OP_D1_230553_0004 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D1_230553_0004 Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212305 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 AGC1-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2009_264_OP_G1_230553_0000 Wrong sample time for this file 1. Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212305 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 D2-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2009_264_OP_D2_230553_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D2_230553_0000 NN13_MEX1_2009_264_OP_D2_230553_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D2_230553_0001 NN13_MEX1_2009_264_OP_D2_230553_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D2_230553_0002 NN13_MEX1_2009_264_OP_D2_230553_0003 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D2_230553_0003 NN13_MEX1_2009_264_OP_D2_230553_0004 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D2_230553_0004 Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212305 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 AGC2-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2009_264_OP_G2_230553_0000 Wrong sample time for this file 1. Files stop too early at 200909212330 instead of 200909212330 The files cover the following time range 200909212305 - 200909212330 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN13 MET-files ++++++++++++++++++++++++++++++++++++ NN13_MEX1_2009_264_OP_ME_211848_0001 NN13_MEX1_2009_264_OP_ME_211848_0002 The files cover the following time range 200909212219 - 200909220018 ++++++++++++++++++++++++++++++++++++ The following files are missing: ++++++++++++++++++++++++++++++++++++ Wrong sample time for this file 1. Wrong sample time for this file 1. Wrong sample time for this file 0. Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D1_230552_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D1_230552_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D1_230552_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D1_230552_0003 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D1_230552_0004 Wrong sample time for this file 1. Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D2_230552_0000 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D2_230552_0001 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D2_230552_0002 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D2_230552_0003 Wrong sample time of 0.1 for OCC-measurement in NN12_MEX1_2009_264_OP_D2_230552_0004 Wrong sample time for this file 1. Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D1_230553_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D1_230553_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D1_230553_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D1_230553_0003 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D1_230553_0004 Wrong sample time for this file 1. Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D2_230553_0000 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D2_230553_0001 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D2_230553_0002 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D2_230553_0003 Wrong sample time of 0.1 for OCC-measurement in NN13_MEX1_2009_264_OP_D2_230553_0004 Wrong sample time for this file 1. ++++++++++++++++++++++++++++++++++++ Please note! For open loop measurements IFMS had a special configuration: IFMS NN12 and NN13 D1 were used for open loop Consequently, IFMS NN12 and NN13 Doppler 1 and IFMS NN12 and NN13 AGC2 files should be missing THIS IS NOT A MISTAKE ++++++++++++++++++++++++++++++++++++