This is a logfile for the mex measurement on 269 Times are given in the format YYYYMMDDhhmm OCC Measurement time: 202009250355 - 202009250417 Checking files of DOY 269 -------------------------------------------------- -------------------------------------------------- ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 D1-files ++++++++++++++++++++++++++++++++++++ CB11_MEX1_2020_269_OP_D1_024906_0001 CB11_MEX1_2020_269_OP_D1_035509_0000 Files stop too early at 202009250417 instead of 202009250417 The files cover the following time range 202009250349 - 202009250417 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 AGC1-files ++++++++++++++++++++++++++++++++++++ CB11_MEX1_2020_269_OP_G1_024906_0010 CB11_MEX1_2020_269_OP_G1_035509_0000 CB11_MEX1_2020_269_OP_G1_035509_0001 CB11_MEX1_2020_269_OP_G1_035509_0002 CB11_MEX1_2020_269_OP_G1_035509_0003 Files stop too early at 202009250417 instead of 202009250417 The files cover the following time range 202009250349 - 202009250417 ++++++++++++++++++++++++++++++++++++ Sorting CL D1-files ++++++++++++++++++++++++++++++++++++ CB11_MEX1_2020_268_CL_D1_032232_0000 CB11_MEX1_2020_268_CL_D1_194724_0000 MG11_MEX1_2020_268_CL_D1_193948_0000 MG11_MEX1_2020_268_CL_D1_194557_0000 NN11_MEX1_2020_269_CL_D1_133442_0000 CB11_MEX1_2020_269_CL_D1_020704_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 D2-files ++++++++++++++++++++++++++++++++++++ CB11_MEX1_2020_269_OP_D2_024906_0010 CB11_MEX1_2020_269_OP_D2_035509_0000 CB11_MEX1_2020_269_OP_D2_035509_0001 CB11_MEX1_2020_269_OP_D2_035509_0002 CB11_MEX1_2020_269_OP_D2_035509_0003 Files stop too early at 202009250417 instead of 202009250417 The files cover the following time range 202009250349 - 202009250417 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 AGC2-files ++++++++++++++++++++++++++++++++++++ CB11_MEX1_2020_269_OP_G2_024906_0010 CB11_MEX1_2020_269_OP_G2_035509_0000 CB11_MEX1_2020_269_OP_G2_035509_0001 CB11_MEX1_2020_269_OP_G2_035509_0002 CB11_MEX1_2020_269_OP_G2_035509_0003 Files stop too early at 202009250417 instead of 202009250417 The files cover the following time range 202009250349 - 202009250417 ++++++++++++++++++++++++++++++++++++ Sorting CL D2-files ++++++++++++++++++++++++++++++++++++ CB11_MEX1_2020_268_CL_D2_032232_0000 CB11_MEX1_2020_268_CL_D2_194724_0000 MG11_MEX1_2020_268_CL_D2_193948_0000 MG11_MEX1_2020_268_CL_D2_194557_0000 CB11_MEX1_2020_269_CL_D2_020704_0000 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN11 MET-files ++++++++++++++++++++++++++++++++++++ CB11_MEX1_2020_269_OP_ME_021430_0001 CB11_MEX1_2020_269_OP_ME_021430_0002 Files stop too early at 202009250416 instead of 202009250417 The files cover the following time range 202009250315 - 202009250416 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 D1-files ++++++++++++++++++++++++++++++++++++ CB12_MEX1_2020_269_OP_D1_024906_0001 Wrong sample time of 1. for OCC-measurement in CB12_MEX1_2020_269_OP_D1_024906_0001 CB12_MEX1_2020_269_OP_D1_035509_0000 Wrong sample time of 1. for OCC-measurement in CB12_MEX1_2020_269_OP_D1_035509_0000 Files stop too early at 202009250417 instead of 202009250417 The files cover the following time range 202009250349 - 202009250417 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 AGC1-files ++++++++++++++++++++++++++++++++++++ CB12_MEX1_2020_269_OP_G1_024906_0010 CB12_MEX1_2020_269_OP_G1_035509_0000 CB12_MEX1_2020_269_OP_G1_035509_0001 CB12_MEX1_2020_269_OP_G1_035509_0002 CB12_MEX1_2020_269_OP_G1_035509_0003 Files stop too early at 202009250417 instead of 202009250417 The files cover the following time range 202009250349 - 202009250417 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 D2-files ++++++++++++++++++++++++++++++++++++ CB12_MEX1_2020_269_OP_D2_024906_0010 CB12_MEX1_2020_269_OP_D2_035509_0000 CB12_MEX1_2020_269_OP_D2_035509_0001 CB12_MEX1_2020_269_OP_D2_035509_0002 CB12_MEX1_2020_269_OP_D2_035509_0003 Files stop too early at 202009250417 instead of 202009250417 The files cover the following time range 202009250349 - 202009250417 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 AGC2-files ++++++++++++++++++++++++++++++++++++ CB12_MEX1_2020_269_OP_G2_024906_0010 CB12_MEX1_2020_269_OP_G2_035509_0000 CB12_MEX1_2020_269_OP_G2_035509_0001 CB12_MEX1_2020_269_OP_G2_035509_0002 CB12_MEX1_2020_269_OP_G2_035509_0003 Files stop too early at 202009250417 instead of 202009250417 The files cover the following time range 202009250349 - 202009250417 ++++++++++++++++++++++++++++++++++++ Sorting and checking NN12 MET-files ++++++++++++++++++++++++++++++++++++ CB12_MEX1_2020_269_OP_ME_021430_0001 CB12_MEX1_2020_269_OP_ME_021430_0002 Files stop too early at 202009250416 instead of 202009250417 The files cover the following time range 202009250315 - 202009250416 ++++++++++++++++++++++++++++++++++++ The following files are missing: ++++++++++++++++++++++++++++++++++++ CB11 D1 for DOY 269 was stoped and restarted CB11 G1 for DOY 269 was stoped and restarted CB11 D2 for DOY 269 was stoped and restarted CB11 G2 for DOY 269 was stoped and restarted Wrong sample time of 1. for OCC-measurement in CB12_MEX1_2020_269_OP_D1_024906_0001 Wrong sample time of 1. for OCC-measurement in CB12_MEX1_2020_269_OP_D1_035509_0000 CB12 D1 for DOY 269 was stoped and restarted CB12 G1 for DOY 269 was stoped and restarted CB12 D2 for DOY 269 was stoped and restarted CB12 G2 for DOY 269 was stoped and restarted NN13 AGC1 for DOY 269 missing NN13 D2 for DOY 269 missing in Z:/incoming/mex/ Meteo files for NN13 missing for DOY 269 ++++++++++++++++++++++++++++++++++++ Please note! For open loop measurements IFMS had a special configuration: IFMS NN12 and NN13 D1 were used for open loop Consequently, IFMS NN12 and NN13 Doppler 1 and IFMS NN12 and NN13 AGC2 files should be missing THIS IS NOT A MISTAKE ++++++++++++++++++++++++++++++++++++