PDS_VERSION = PDS3 RECORD_TYPE = STREAM OBJECT = TEXT PUBLICATION_DATE = 1997-01-15 NOTE = "MGS RST Instrument Health Report HEA7015A.TXT" END_OBJECT = TEXT END Engineering Data ================ Engineering Data Statistical Summary from CSV2STAT: First SCET: 1997-01-14T00:00:00.920 Last SCET: 1997-01-14T23:59:12.417 CHANNL channel name DN-LO smallest data number DN-MD median data number DN-HI largest data number EU-LO smallest engineering value EU-MEDIAN median engineering value EU-HIGH largest engineering value EU AVG/STDDEV engineering value mean and standard deviation RECDS records contributing to statistics CHANNL DN-LO DN-MD DN-HI EU-LO EU-MEDIAN EU-HIGH EU AVG/STDEV RECDS ------ ----- ----- ----- --------- --------- --------- --------- -------- ----- L-0200 203 204 205 4.06E+00 4.08E+00 4.10E+00 4.08E+00/2.15E-04 657 L-0201 127 128 130 2.54E+00 2.56E+00 2.60E+00 2.56E+00/3.32E-04 657 T-0315 146 149 153 1.80E+01 1.91E+01 2.00E+01 1.90E+01/2.26E-02 469 L-0200 (USO regulator voltage) remains constant. L-0201 (USO oven voltage) continues to drop slowly; median is down another 0.02 volts from the previous 24-hr period. T-0315 (USO temperature) is also down again; median is 19.1C compared with 19.4C during the previous 24-hr period. Open Loop Data ============== Data Collection --------------- No new data; but USO Test #4 is scheduled for tonight (local time). Closed Loop Data ================ We have obtained ATDF 96342t002.dat from OSCAR, which apparently covers USO Tests #2 (for which we have open loop data) and #3 (for which there was closed loop data only). But our reader, which was recently revised to handle the new ATDF formats, is returning an unexpected error. We are investigating.