PDS_VERSION = PDS3 RECORD_TYPE = STREAM OBJECT = TEXT PUBLICATION_DATE = 1997-02-17 NOTE = "MGS RST Instrument Health Report HEA7047A.TXT" END_OBJECT = TEXT END Errata ====== Carl Kloss points out that spacecraft systems were turned on BEFORE launch. My report yesterday should have said simply that our current USO temperatures are the lowest since the USO was powered up. Engineering Data ================ Engineering Data Statistical Summary from CSV2STAT: First SCET: 1997-02-16T01:33:00.738 Last SCET: 1997-02-16T23:59:59.735 CHANNL CHANNEL TITLE DN-LO DN-HI EU-LO EU-HI EU-AVG/STDEV RECDS ------ ------------- ----- ----- --------- --------- ---------/-------- ----- L-0037 MOT1_USO_ENA 0 0 34463 L-0047 MOT2_USO_ENA 1 1 34463 L-0060 TWTA1_FILMNT 0 0 34463 L-0061 TWTA1_HV 0 0 34464 L-0070 TWTA2_FILMNT 1 1 34464 L-0071 TWTA2_HV 0 0 34463 L-0080 USO_PWR 0 0 34463 L-0111 MOT1_RCV_AGC 243 255 -1.52E+02 -1.46E+02 -1.52E+02/7.06E-04 17232 L-0121 MOT2_RCV_AGC 111 255 -1.53E+02 -1.04E+02 -1.12E+02/9.19E-02 17232 L-0131 TWTA1_HLX_I 0 1 -3.84E-02 -1.85E-02 -3.83E-02/8.75E-06 17232 L-0132 TWTA1_ANOD_V 0 2 -1.00E+03 -1.00E+03 -1.00E+03/2.21E-03 17232 L-0141 TWTA2_HLX_I 38 43 7.05E-01 8.05E-01 7.52E-01/1.17E-04 17232 L-0142 TWTA2_ANOD_V 59 64 -8.70E+02 -8.60E+02 -8.65E+02/1.18E-02 17232 L-0200 USO_REG_V 203 205 4.06E+00 4.10E+00 4.08E+00/5.91E-05 17232 L-0201 USO_OVEN_V 123 126 2.46E+00 2.52E+00 2.48E+00/5.63E-05 17232 T-0302 EPC1_T 107 127 2.46E+01 3.33E+01 2.68E+01/2.92E-02 4307 T-0303 EPC2_T 100 133 2.20E+01 3.63E+01 2.51E+01/4.92E-02 4307 T-0310 RF_ISOLTR1_T 172 202 1.93E+01 3.10E+01 2.21E+01/2.08E-02 17232 T-0311 RF_ISOLTR2_T 158 182 2.75E+01 3.60E+01 2.94E+01/1.37E-02 17232 T-0312 TWT1_T 170 204 1.83E+01 3.17E+01 2.17E+01/4.84E-02 4307 T-0313 TWT2_T 153 180 2.82E+01 3.78E+01 3.06E+01/3.29E-02 4307 T-0315 USO_T 178 181 9.61E+00 1.06E+01 1.00E+01/2.13E-03 4307 Open Loop Data ============== Data Collection --------------- A query for retransmitted data from USO Test #6 (97/043) is in progress. Trish Priest says that she has found no missing records after this retrans- mission. A retransmission immediately after the test left us with 7 missing records. Closed Loop Data ================ New Data -------- ODF: 97045C048.DAT;1 EOP: 970214-eop.short