PDS_VERSION_ID = PDS3 RECORD_TYPE = STREAM OBJECT = TEXT PUBLICATION_DATE = 2002-08-14 NOTE = "MGS RST Instrument Health Report HEA2226A.TXT" END_OBJECT = TEXT END Engineering Data ================ Engineering Data Statistical Summary from CSV2STAT: First SCET: 2002-08-12T14:21:14.582 Last SCET: 2002-08-12T21:22:22.578 CHANNL CHANNEL TITLE DN-LO DN-HI EU-LO EU-HI EU-AVG/STDEV RECDS ------ ------------- ----- ----- --------- --------- ---------/-------- ----- F-0190 HGA_AZ_ANG 10897 10935 2.66E+00 2.67E+00 2.66E+00/1.25E-04 351 F-0195 HGA_EL_ANG -11233 10934 -2.74E+00 2.67E+00 3.29E-01/1.07E-01 351 L-0034 MOT1_RANGING 0 0 738 L-0036 MOT1_TLM_MOD 0 0 724 L-0037 MOT1_USO_ENA 0 0 738 L-0044 MOT2_RANGING 0 0 738 L-0046 MOT2_TLM_MOD 1 1 724 L-0047 MOT2_USO_ENA 1 1 738 L-0053 RF_SW_OSC 2 2 724 L-0060 TWTA1_FILMNT 0 0 738 L-0061 TWTA1_HV 0 0 729 L-0070 TWTA2_FILMNT 1 1 729 L-0071 TWTA2_HV 0 0 738 L-0080 USO_PWR 0 0 738 L-0090 KaBLE_STAT 0 0 738 L-0091 KaBLE_ENABLE 1 1 729 L-0111 MOT1_RCV_AGC 255 255 -1.53E+02 -1.53E+02 -1.53E+02/0.00E+00 738 L-0121 MOT2_RCV_AGC 255 255 -1.53E+02 -1.53E+02 -1.53E+02/0.00E+00 738 L-0131 TWTA1_HLX_I 0 1 -3.84E-02 -1.85E-02 -3.82E-02/7.08E-05 738 L-0132 TWTA1_ANOD_V 0 1 -1.00E+03 -1.00E+03 -1.00E+03/2.07E-02 96 L-0141 TWTA2_HLX_I 38 43 7.05E-01 8.05E-01 7.52E-01/5.26E-04 738 L-0142 TWTA2_ANOD_V 63 65 -8.62E+02 -8.58E+02 -8.60E+02/1.44E-01 96 L-0200 USO_REG_V 203 205 4.06E+00 4.10E+00 4.08E+00/7.03E-04 94 L-0201 USO_OVEN_V 128 130 2.56E+00 2.60E+00 2.57E+00/1.02E-03 94 T-0302 EPC1_T 190 196 -4.19E+00 -1.58E+00 -2.59E+00/6.41E-02 92 T-0303 EPC2_T 182 191 -2.00E+00 1.71E+00 4.22E-01/8.80E-02 92 T-0310 RF_ISOLTR1_T 229 233 -6.05E+00 -1.15E+00 -3.53E+00/2.29E-02 724 T-0311 RF_ISOLTR2_T 225 231 -3.52E+00 3.13E+00 1.72E-02/5.17E-02 724 T-0312 TWT1_T 229 231 -3.52E+00 -1.15E+00 -2.44E+00/7.25E-02 90 T-0313 TWT2_T 219 232 -4.77E+00 8.56E+00 4.63E+00/3.18E-01 90 T-0315 USO_T 147 149 1.91E+01 1.97E+01 1.94E+01/1.20E-02 92 T-0316 KA_AMP_T 215 219 8.56E+00 1.16E+01 1.00E+01/6.52E-02 84 L-0200, L-0201, and T-0315 are nominal. Open Loop Data ============== No new data. Closed Loop Data ================ Data Collection --------------- We have obtained the following files from OSCAR and EPIC: Original File Name Name on SOPC ------------------------------------ ------------ ODF: 02224O226_10S.SJO;1 2225226A.ODF EOP: 020813-eop.long 20202308.EOP EOP: 020813-eop.short 13072308.EOP Ancillary Data ============== Data Collection --------------- We have obtained the following files from the DOM: Original File Name Name on SOPC ------------------------------------ ------------ AMD: amdgen.02-225.out 2225225A.AMD DKF: mm201b.04.dkf 2227232D.DKF OPT: optg_m_020812_OD15325-15328_15582_V1 2224245A.OPT OPT: optg_m_020814_OD15348-15350_15611_V1 2226248A.OPT SAK: mgs_solar_array_2002-224.ck 2224224A.SAK SOE: mm201b.04.tsoe 2227232D.SOE SPK: spk_m_020812_OD15325-15328_15582_V1 2224245A.SPK SPK: spk_m_020814_OD15348-15350_15611_V1 2226248A.SPK TCK: mgs_spice_c_kernel_2002-224.ck 2224224A.TCK We have obtained the following files from NAIF: Original File Name Name on SOPC ------------------------------------ ------------ AGK: mgs_hga_ck_2002-08-04.bc 2216216A.AGK MOLA POD Team Orbit Solutions ============================= Data Collection --------------- We have obtained the following files from GEODESY: Original File Name Name on SOPC ------------------------------------ ------------ GDN: gdn_ql18_204151845_204221610.tsp 2105112A.GDN GDN: gdn_ql18_204200810_204271110.tsp 2110117A.GDN Figure Caption ============== HEA2226A.PS1: One-way MGS Doppler noise during pre-solar conjunction 2002. Figure provided by Pat Esposito of the MGS NAV Team. HEA2226A.PS2: Two-way MGS Doppler noise during pre-solar conjunction 2002. Figure provided by Pat Esposito of the MGS NAV Team." Figures ======= Plot(s) illustrate some of the points made in the text. Each plot is a PostScript file, created and printable on our SOPC. For report text file HEAydddC.TXT Figure N will be labeled HEAydddC.PSN and sent as the N+1st e-mail message of a set. We assume that you can strip off the e-mail headers and either display or print copies of the figures on a machine in your area. People who have indicated that they cannot handle these files by e-mail are not included in the e-mail distribution of figures.