PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "2005-12-11, P. Cavender corrected syntax; 2006-09-18, MRO CRISM:HWT line length fix" DATA_SET_ID = "MRO-M-CRISM-4/6-CDR-V1.0" /* The time string in the prouct ID will increment when a new entry is made */ PRODUCT_ID = "CDR6_2_0811260000_DC_J_1" PRODUCT_TYPE = CDR SPACECRAFT_ID = MRO INSTRUMENT_ID = CRISM /* The start time field will increment when a new entry is made */ START_TIME = 2005-09-15T14:00:00 STOP_TIME = NULL /* The start clock count field will increment when a new entry is made */ SPACECRAFT_CLOCK_START_COUNT = "2/811260000" SPACECRAFT_CLOCK_STOP_COUNT = NULL /* The creation time field will increment when a new entry is made */ PRODUCT_CREATION_TIME = 2005-10-11T14:00:00 MRO:SENSOR_ID = "J" PRODUCT_VERSION_ID = "0" /* CRISM Data Structure History File */ /* */ /* The purpose of this file to provide a time history of the active values */ /* in CRISM's onboard data alarm limit and parameter data structures. The */ /* alarm limit data structure defines the subsystem currents, voltages, and */ /* temperatures that trigger generation of an alarm packets. Some of the */ /* alarms trigger safing of subsystems. The parameters data structure */ /* contains constants that control timeout of lamps and coolers and the */ /* cooler control algorithm. Default values are stored in permanent memory */ /* (EEPROM). From time to time these are overwritten via command or by */ /* execution of macros. */ /* */ /* In this file, alarm limts are physical units of volts, amperes, or */ /* degrees Celsius. */ /* */ /* Time spans over which a set of values is applicable are demarcated by */ /* one of four events: specific commands, execution of specific macros, */ /* writing new defaults to EEPROM, or power cycling of the instrument which */ /* causes defaults to become active. */ OBJECT = FILE /* The time string in the table file name will increment upon a new entry */ ^TABLE = "CDR6_2_0811260000_DC_J_1.TAB" RECORD_TYPE = FIXED_LENGTH FILE_RECORDS = 5 OBJECT = TABLE NAME = "CRISM DATA STRUCTURE HISTORY FILE" INTERCHANGE_FORMAT = "ASCII" /* The rows field will increment by one when a new entry is made */ ROWS = 5 COLUMNS = 102 ROW_BYTES = 1470 DESCRIPTION = "Calibrated CRISM Data Structure History File" OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = SPACECRAFT_CLOCK_START_COUNT DATA_TYPE = CHARACTER UNIT = NULL START_BYTE = 1 BYTES = 10 DESCRIPTION = "SCLK at the start time of the span during which the data structure values are active" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = START_TIME DATA_TYPE = TIME UNIT = UTC START_BYTE = 12 BYTES = 19 DESCRIPTION = "UTC at the start time of the span during which the data structure values are active" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = STATUS DATA_TYPE = CHARACTER START_BYTE = 32 BYTES = 10 DESCRIPTION = "HISTORICAL if the row of values represents values that nave been active in CRISM. PLANNED if the values represent defaults or macro values anticipated to be used. PROPOSED if the values represent anticipated replacements for the defaults or macro values." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 4 NAME = DPU_BOARD_TEMP_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 43 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_0; DPU power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 5 NAME = DPU_BOARD_TEMP_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 53 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_0; DPU power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 6 NAME = DPU_P5_VOLTAGE_LO DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 63 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_1; DPU +5 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 7 NAME = DPU_P5_VOLTAGE_HI DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 73 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_1; DPU +5 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 8 NAME = DPU_P5_CURRENT_LO DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 83 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_3; DPU +5 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 9 NAME = DPU_P5_CURRENT_HI DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 93 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_3; DPU +5 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 10 NAME = SCAN_MOT_CURR_LO DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 103 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_4; Scan motor current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 11 NAME = SCAN_MOT_CURR_HI DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 113 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_4; Scan motor current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 12 NAME = IR_BOARD_TEMP_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 123 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_0; IR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 13 NAME = IR_BOARD_TEMP_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 133 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_0; IR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 14 NAME = IR_FPU_P12_VOLTAGE_LO DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 143 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_1; IR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 15 NAME = IR_FPU_P12_VOLTAGE_HI DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 153 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_1; IR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 16 NAME = IR_FPU_P7_VOLTAGE_LO DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 163 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_2; IR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 17 NAME = IR_FPU_P7_VOLTAGE_HI DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 173 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_2; IR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 18 NAME = IR_FPU_CURRENT_LO DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 183 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_3; IR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 19 NAME = IR_FPU_CURRENT_HI DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 133 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_3; IR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 20 NAME = HEATER_34_CURRENT_LO DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 193 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_4; heater 3 & 4 current; on cooler radiator and spectrometer housing" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 21 NAME = HEATER_34_CURRENT_HI DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 203 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_4; heater 3 & 4 current; on cooler radiator and spectrometer housing" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 22 NAME = VNIR_BOARD_TEMP_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 213 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_0; VNIR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 23 NAME = VNIR_BOARD_TEMP_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 223 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_0; VNIR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 24 NAME = VNIR_FPU_P12_VOLTAGE_LO DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 233 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_1; VNIR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 25 NAME = VNIR_FPU_P12_VOLTAGE_HI DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 243 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_1; VNIR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 26 NAME = VNIR_FPU_P7_VOLTAGE_LO DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 253 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_2; VNIR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 27 NAME = VNIR_FPU_P7_VOLTAGE_HI DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 263 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_2; VNIR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 28 NAME = VNIR_FPU_CURRENT_LO DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 273 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_3; VNIR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 29 NAME = VNIR_FPU_CURRENT_HI DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 283 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_3; VNIR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 30 NAME = HEATER_12_CURRENT_LO DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 293 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_4; Heater 1 & 2 (on gimbal electronics housing) current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 31 NAME = HEATER_12_CURRENT_HI DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 303 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_4; Heater 1 & 2 (on gimbal electronics housing) current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 32 NAME = COOL_BOARD_TEMP_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 313 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_0; Cooler power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 33 NAME = COOL_BOARD_TEMP_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 323 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_0; Cooler power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 34 NAME = COOL_P15_VOLTAGE_LO DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 333 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_1; Cooler +15 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 35 NAME = COOL_P15_VOLTAGE_HI DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 343 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_1; Cooler +15 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 36 NAME = COOL_CURRENT_LO DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 353 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_3; cooler current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 37 NAME = COOL_CURRENT_HI DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 363 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_3; cooler current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 38 NAME = HOP_HEATER_12_CURR_LO DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 373 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_4; HOP heater 1 & 2 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 39 NAME = HOP_HEATER_12_CURR_HI DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 383 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_4; HOP heater 1 & 2 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 40 NAME = SHUT_MOTOR_CURR_IR_LO DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 393 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_0; Shutter motor current (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 41 NAME = SHUT_MOTOR_CURR_IR_HI DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 403 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_0; Shutter motor current (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 42 NAME = IR_DETECTOR_TEMP1_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 413 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_1; IR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 43 NAME = IR_DETECTOR_TEMP1_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 423 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_1; IR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 44 NAME = IR_DETECTOR_TEMP2_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 433 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_2; IR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 45 NAME = IR_DETECTOR_TEMP2_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 443 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_2; IR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 46 NAME = COOLER_TEMP1_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 453 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_3; cooler temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 47 NAME = COOLER_TEMP1_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 463 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_3; cooler temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 48 NAME = COOLER_TEMP2_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 473 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_4; cooler temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 49 NAME = COOLER_TEMP2_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 483 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_4; cooler temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 50 NAME = COOLER_TEMP3_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 493 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_5; cooler temperature 3" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 51 NAME = COOLER_TEMP3_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 503 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_5; cooler temperature 3" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 52 NAME = SHUT_MOTOR_TEMP_IR_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 513 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_6; shutter motor temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 53 NAME = SHUT_MOTOR_TEMP_IR_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 523 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_6; shutter motor temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 54 NAME = SPHERE_TEMP_IR_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 533 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_7; integrating sphere temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 55 NAME = SPHERE_TEMP_IR_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 543 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_7; integrating sphere temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 56 NAME = SPIDER_TEMP_IR_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 553 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_8; telescope spider temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 57 NAME = SPIDER_TEMP_IR_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 563 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_8; telescope spider temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 58 NAME = SPECT_CAVITY_TEMP_IR_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 573 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_9; spectral cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 59 NAME = SPECT_CAVITY_TEMP_IR_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 583 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_9; spectral cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 60 NAME = OSU_CAVITY_TEMP_IR_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 593 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_10; OSU cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 61 NAME = OSU_CAVITY_TEMP_IR_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 603 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_10; OSU cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 62 NAME = IR_FPU_BOARD_TEMP_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 613 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_11; IR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 63 NAME = IR_FPU_BOARD_TEMP_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 623 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_11; IR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 64 NAME = IR_SPHERE_CURR_LO DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 633 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_12; IR sphere lamp current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 65 NAME = IR_SPHERE_CURR_HI DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 643 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_12; IR sphere lamp current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 66 NAME = HOP_TEMP_IR_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 653 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_13; HOP temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 67 NAME = HOP_TEMP_IR_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 663 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_13; HOP temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 68 NAME = SHUT_MOTOR_CURR_VNIR_LO DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 673 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_0; shutter motor current (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 69 NAME = SHUT_MOTOR_CURR_VNIR_HI DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 683 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_0; shutter motor current (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 70 NAME = VNIR_DETECTOR_TEMP1_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 693 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_1; VNIR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 71 NAME = VNIR_DETECTOR_TEMP1_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 703 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_1; VNIR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 72 NAME = VNIR_DETECTOR_TEMP2_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 713 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_2; VNIR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 73 NAME = VNIR_DETECTOR_TEMP2_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 723 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_2; VNIR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 74 NAME = TELESCOPE_TEMP_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 733 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_3; telescope temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 75 NAME = TELESCOPE_TEMP_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 743 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_3; telescope temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 76 NAME = OPTICAL_BENCH_TEMP_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 753 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_4; optical bench temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 77 NAME = OPTICAL_BENCH_TEMP_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 763 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_4; optical bench temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 78 NAME = SPIDER_TEMP_VNIR_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 773 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_5; telescope spider temp. (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 79 NAME = SPIDER_TEMP_VNIR_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 783 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_5; telescope spider temp. (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 80 NAME = SPECT_CAVITY_TEMP_VNIR_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 793 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_6; spectral cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 81 NAME = SPECT_CAVITY_TEMP_VNIR_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 803 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_6; spectral cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 82 NAME = OSU_CAVITY_TEMP_VNIR_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 813 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_7; OSU cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 83 NAME = OSU_CAVITY_TEMP_VNIR_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 823 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_7; OSU cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 84 NAME = VNIR_FPU_BOARD_TEMP_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 833 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_8; VNIR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 85 NAME = VNIR_FPU_BOARD_TEMP_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 843 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_8; VNIR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 86 NAME = BAFFLETEMP_LO DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 853 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_9; baffle temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 87 NAME = BAFFLETEMP_HI DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 863 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_9; baffle temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 88 NAME = COOL_ON DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 873 BYTES = 5 DESCRIPTION = "Time which cooler can remain on before it is shut down by software. 20 seconds allows operation in air without icing. 65535 is forever." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 89 NAME = COOL_OFF DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 879 BYTES = 5 DESCRIPTION = "Time which a single cooler must remain off before it can be powered." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 90 NAME = COOL_SWITCH DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 885 BYTES = 5 DESCRIPTION = "Time which all coolers must remain off before any cooler can be powered. 1800 seconds allows a heat pipe to cease functioning so that before a new cooler is powered, the cooler previously shut down becomes thermally isolated from the detector." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 91 NAME = COOL_MAX DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 891 BYTES = 5 DESCRIPTION = "Maximum valid value of cooler level." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 92 NAME = COOL_ERROR DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 897 BYTES = 5 DESCRIPTION = "Maximum difference between cooler cold tip goal temperature and actual cooler cold tip temperature (in raw counts) at which inner cooler control loop - within in about 10K of goal - is operative." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 93 NAME = COOL_CLAMP DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 903 BYTES = 5 DESCRIPTION = "Value used in inner control loop of cooler. Smallest temperature difference between goal and actual cooler cold tip temperature to feed into control loop." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 94 NAME = COOL_INT DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 909 BYTES = 5 DESCRIPTION = "Value used in inner control loop of cooler. The inner loop integrates the temperature difference between goal and actual cooler cold tip temperature. The integral is what drives how hard the cooler works, i.e. This is the limit to the value of the integral." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 95 NAME = COOL_KP DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 915 BYTES = 5 DESCRIPTION = "Value used in outer control loop of cooler. The outer loop examines the temperature difference between goal and actual cooler cold tip temperature, and drives the cooler to a level related to the temperature difference. This value is a gain in the control algorithm." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 96 NAME = COOL_KI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 921 BYTES = 5 DESCRIPTION = "Gain used in inner control loop of cooler." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 97 NAME = COOL_OFFSET DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 927 BYTES = 5 DESCRIPTION = "Offset used in inner control loop of cooler." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 98 NAME = CAL_ON DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 933 BYTES = 5 DESCRIPTION = "Maximum amount of time in seconds that a calibration lamp may remain on before it is powered down by software." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 99 NAME = CAL_OFF DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 939 BYTES = 5 DESCRIPTION = "Minimum amount of time in seconds that a single calibration lamp must remain off until software allows it to be turned on." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 100 NAME = CAL_BOTH DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 945 BYTES = 5 DESCRIPTION = "Minimum amount of time in seconds that both VNIR focal plane lamps or both IR focal plane lamps must remain off until software allows either to be turned on." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 101 NAME = HOP_ON DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 951 BYTES = 5 DESCRIPTION = "Maximum amount of time in seconds that the high output paraffin actuator (HOP) that opens the cover may remain on until software powers it off." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 102 NAME = COMMENT DATA_TYPE = CHARACTER START_BYTE = 957 BYTES = 512 DESCRIPTION = "Description of reason for change in current values in data structures." END_OBJECT = COLUMN END_OBJECT = TABLE END_OBJECT = FILE END