PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "2005-12-19, S. Murchie; 2006-09-18, MRO CRISM:HWT line length fix" DATA_SET_ID = "MRO-M-CRISM-4/6-CDR-V1.0" /* The time string in the product ID will increment when a new entry is made*/ PRODUCT_ID = "CDR6_2_0818985600_DC_J_0" PRODUCT_TYPE = CDR SPACECRAFT_ID = MRO INSTRUMENT_ID = CRISM /* The start time field will increment when a new entry is made */ START_TIME = 2005-12-14T00:00:00 STOP_TIME = NULL /* The start clock count field will increment when a new entry is made */ SPACECRAFT_CLOCK_START_COUNT = "2/0818985600" SPACECRAFT_CLOCK_STOP_COUNT = NULL /* The creation time field will increment when a new entry is made */ PRODUCT_CREATION_TIME = 2005-12-19T14:00:00 MRO:SENSOR_ID = "J" PRODUCT_VERSION_ID = "0" /* CRISM Data Structure History File */ /* */ /* The purpose of this file to provide a time history of the active values */ /* in CRISM's onboard data alarm limit and parameter data structures. The */ /* alarm limit data structure defines the subsystem currents, voltages, and */ /* temperatures that trigger generation of an alarm packets. Some of the */ /* alarms trigger safing of subsystems. The parameters data structure */ /* contains constants that control timeout of lamps and coolers and the */ /* cooler control algorithm. Default values are stored in permanent memory */ /* (EEPROM). From time to time these are overwritten via command or by */ /* execution of macros. */ /* */ /* In this file, alarm limts are physical units of volts, amperes, or */ /* degrees Celsius. */ /* */ /* Time spans over which a set of values is applicable are demarcated by */ /* one of four events: specific commands, execution of specific macros, */ /* writing new defaults to EEPROM, or power cycling of the instrument */ /* which causes defaults to become active. */ OBJECT = FILE /* The time string in the table file name will increment upon a new entry */ ^TABLE = "CDR6_2_0818985600_DC_J_0.TAB" RECORD_TYPE = VARIABLE_LENGTH FILE_RECORDS = 5 OBJECT = TABLE NAME = "CRISM DATA STRUCTURE HISTORY FILE" INTERCHANGE_FORMAT = "ASCII" /* The rows field will increment by one when a new entry is made */ ROWS = 7 COLUMNS = 102 ROW_BYTES = 1472 DESCRIPTION = "Calibrated CRISM Data Structure History File" OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = "SPACECRAFT_CLOCK_START_COUNT" DATA_TYPE = CHARACTER UNIT = NULL START_BYTE = 1 BYTES = 12 DESCRIPTION = "SCLK at the start time of the span during which the data structure values are active" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = "START_TIME" DATA_TYPE = TIME UNIT = UTC START_BYTE = 14 BYTES = 19 DESCRIPTION = "UTC at the start time of the span during which the data structure values are active" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = "STATUS" DATA_TYPE = CHARACTER START_BYTE = 34 BYTES = 10 DESCRIPTION = "HISTORICAL if the row of values represents values that nave been active in CRISM. PLANNED if the values represent defaults or macro values anticipated to be used. PROPOSED if the values represent anticipated replacements for the defaults or macro values." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 4 NAME = "DPU_BOARD_TEMP_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 45 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_0; DPU power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 5 NAME = "DPU_BOARD_TEMP_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 55 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_0; DPU power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 6 NAME = "DPU_P5_VOLTAGE_LO" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 65 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_1; DPU +5 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 7 NAME = "DPU_P5_VOLTAGE_HI" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 75 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_1; DPU +5 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 8 NAME = "DPU_P5_CURRENT_LO" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 85 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_3; DPU +5 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 9 NAME = "DPU_P5_CURRENT_HI" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 95 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_3; DPU +5 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 10 NAME = "SCAN_MOT_CURR_LO" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 105 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_4; Scan motor current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 11 NAME = "SCAN_MOT_CURR_HI" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 115 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_4; Scan motor current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 12 NAME = "IR_BOARD_TEMP_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 125 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_0; IR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 13 NAME = "IR_BOARD_TEMP_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 135 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_0; IR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 14 NAME = "IR_FPU_P12_VOLTAGE_LO" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 145 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_1; IR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 15 NAME = "IR_FPU_P12_VOLTAGE_HI" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 155 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_1; IR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 16 NAME = "IR_FPU_P7_VOLTAGE_LO" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 165 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_2; IR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 17 NAME = "IR_FPU_P7_VOLTAGE_HI" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 175 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_2; IR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 18 NAME = "IR_FPU_CURRENT_LO" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 185 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_3; IR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 19 NAME = "IR_FPU_CURRENT_HI" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 135 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_3; IR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 20 NAME = "HEATER_34_CURRENT_LO" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 195 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_4; heater 3 & 4 current; on cooler radiator and spectrometer housing" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 21 NAME = "HEATER_34_CURRENT_HI" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 205 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_4; heater 3 & 4 current; on cooler radiator and spectrometer housing" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 22 NAME = "VNIR_BOARD_TEMP_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 215 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_0; VNIR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 23 NAME = "VNIR_BOARD_TEMP_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 225 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_0; VNIR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 24 NAME = "VNIR_FPU_P12_VOLTAGE_LO" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 235 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_1; VNIR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 25 NAME = "VNIR_FPU_P12_VOLTAGE_HI" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 245 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_1; VNIR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 26 NAME = "VNIR_FPU_P7_VOLTAGE_LO" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 255 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_2; VNIR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 27 NAME = "VNIR_FPU_P7_VOLTAGE_HI" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 265 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_2; VNIR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 28 NAME = "VNIR_FPU_CURRENT_LO" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 275 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_3; VNIR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 29 NAME = "VNIR_FPU_CURRENT_HI" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 285 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_3; VNIR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 30 NAME = "HEATER_12_CURRENT_LO" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 295 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_4; Heater 1 & 2 (on gimbal electronics housing) current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 31 NAME = "HEATER_12_CURRENT_HI" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 305 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_4; Heater 1 & 2 (on gimbal electronics housing) current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 32 NAME = "COOL_BOARD_TEMP_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 315 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_0; Cooler power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 33 NAME = "COOL_BOARD_TEMP_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 325 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_0; Cooler power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 34 NAME = "COOL_P15_VOLTAGE_LO" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 335 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_1; Cooler +15 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 35 NAME = "COOL_P15_VOLTAGE_HI" DATA_TYPE = ASCII_REAL UNIT = VOLTS START_BYTE = 345 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_1; Cooler +15 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 36 NAME = "COOL_CURRENT_LO" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 355 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_3; cooler current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 37 NAME = "COOL_CURRENT_HI" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 365 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_3; cooler current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 38 NAME = "HOP_HEATER_12_CURR_LO" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 375 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_4; HOP heater 1 & 2 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 39 NAME = "HOP_HEATER_12_CURR_HI" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 385 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_4; HOP heater 1 & 2 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 40 NAME = "SHUT_MOTOR_CURR_IR_LO" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 395 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_0; Shutter motor current (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 41 NAME = "SHUT_MOTOR_CURR_IR_HI" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 405 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_0; Shutter motor current (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 42 NAME = "IR_DETECTOR_TEMP1_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 415 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_1; IR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 43 NAME = "IR_DETECTOR_TEMP1_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 425 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_1; IR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 44 NAME = "IR_DETECTOR_TEMP2_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 435 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_2; IR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 45 NAME = "IR_DETECTOR_TEMP2_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 445 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_2; IR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 46 NAME = "COOLER_TEMP1_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 455 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_3; cooler temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 47 NAME = "COOLER_TEMP1_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 465 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_3; cooler temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 48 NAME = "COOLER_TEMP2_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 475 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_4; cooler temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 49 NAME = "COOLER_TEMP2_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 485 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_4; cooler temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 50 NAME = "COOLER_TEMP3_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 495 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_5; cooler temperature 3" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 51 NAME = "COOLER_TEMP3_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 505 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_5; cooler temperature 3" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 52 NAME = "SHUT_MOTOR_TEMP_IR_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 515 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_6; shutter motor temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 53 NAME = "SHUT_MOTOR_TEMP_IR_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 525 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_6; shutter motor temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 54 NAME = "SPHERE_TEMP_IR_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 535 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_7; integrating sphere temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 55 NAME = "SPHERE_TEMP_IR_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 545 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_7; integrating sphere temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 56 NAME = "SPIDER_TEMP_IR_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 555 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_8; telescope spider temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 57 NAME = "SPIDER_TEMP_IR_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 565 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_8; telescope spider temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 58 NAME = "SPECT_CAVITY_TEMP_IR_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 575 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_9; spectral cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 59 NAME = "SPECT_CAVITY_TEMP_IR_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 585 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_9; spectral cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 60 NAME = "OSU_CAVITY_TEMP_IR_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 595 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_10; OSU cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 61 NAME = "OSU_CAVITY_TEMP_IR_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 605 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_10; OSU cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 62 NAME = "IR_FPU_BOARD_TEMP_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 615 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_11; IR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 63 NAME = "IR_FPU_BOARD_TEMP_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 625 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_11; IR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 64 NAME = "IR_SPHERE_CURR_LO" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 635 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_12; IR sphere lamp current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 65 NAME = "IR_SPHERE_CURR_HI" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 645 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_12; IR sphere lamp current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 66 NAME = "HOP_TEMP_IR_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 655 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_13; HOP temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 67 NAME = "HOP_TEMP_IR_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 665 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_13; HOP temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 68 NAME = "SHUT_MOTOR_CURR_VNIR_LO" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 675 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_0; shutter motor current (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 69 NAME = "SHUT_MOTOR_CURR_VNIR_HI" DATA_TYPE = ASCII_REAL UNIT = AMPERES START_BYTE = 685 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_0; shutter motor current (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 70 NAME = "VNIR_DETECTOR_TEMP1_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 695 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_1; VNIR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 71 NAME = "VNIR_DETECTOR_TEMP1_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 705 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_1; VNIR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 72 NAME = "VNIR_DETECTOR_TEMP2_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 715 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_2; VNIR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 73 NAME = "VNIR_DETECTOR_TEMP2_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 725 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_2; VNIR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 74 NAME = "TELESCOPE_TEMP_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 735 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_3; telescope temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 75 NAME = "TELESCOPE_TEMP_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 745 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_3; telescope temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 76 NAME = "OPTICAL_BENCH_TEMP_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 755 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_4; optical bench temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 77 NAME = "OPTICAL_BENCH_TEMP_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 765 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_4; optical bench temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 78 NAME = "SPIDER_TEMP_VNIR_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 775 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_5; telescope spider temp. (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 79 NAME = "SPIDER_TEMP_VNIR_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 785 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_5; telescope spider temp. (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 80 NAME = "SPECT_CAVITY_TEMP_VNIR_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 795 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_6; spectral cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 81 NAME = "SPECT_CAVITY_TEMP_VNIR_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 805 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_6; spectral cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 82 NAME = "OSU_CAVITY_TEMP_VNIR_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 815 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_7; OSU cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 83 NAME = "OSU_CAVITY_TEMP_VNIR_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 825 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_7; OSU cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 84 NAME = "VNIR_FPU_BOARD_TEMP_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 835 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_8; VNIR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 85 NAME = "VNIR_FPU_BOARD_TEMP_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 845 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_8; VNIR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 86 NAME = "BAFFLETEMP_LO" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 855 BYTES = 9 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_9; baffle temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 87 NAME = "BAFFLETEMP_HI" DATA_TYPE = ASCII_REAL UNIT = CELSIUS START_BYTE = 865 BYTES = 9 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_9; baffle temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 88 NAME = "COOL_ON" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 875 BYTES = 5 DESCRIPTION = "Time which cooler can remain on before it is shut down by software. 20 seconds allows operation in air without icing. 65535 is forever." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 89 NAME = "COOL_OFF" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 881 BYTES = 5 DESCRIPTION = "Time which a single cooler must remain off before it can be powered." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 90 NAME = "COOL_SWITCH" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 887 BYTES = 5 DESCRIPTION = "Time which all coolers must remain off before any cooler can be powered. 1800 seconds allows a heat pipe to cease functioning so that before a new cooler is powered, the cooler previously shut down becomes thermally isolated from the detector." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 91 NAME = "COOL_MAX" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 893 BYTES = 5 DESCRIPTION = "Maximum valid value of cooler level." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 92 NAME = "COOL_ERROR" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 899 BYTES = 5 DESCRIPTION = "Maximum difference between cooler cold tip goal temperature and actual cooler cold tip temperature (in raw counts) at which inner cooler control loop - within in about 10K of goal - is operative." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 93 NAME = "COOL_CLAMP" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 905 BYTES = 5 DESCRIPTION = "Value used in inner control loop of cooler. Smallest temperature difference between goal and actual cooler cold tip temperature to feed into control loop." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 94 NAME = "COOL_INT" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 911 BYTES = 5 DESCRIPTION = "Value used in inner control loop of cooler. The inner loop integrates the temperature difference between goal and actual cooler cold tip temperature. The integral is what drives how hard the cooler works, i.e. This is the limit to the value of the integral." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 95 NAME = "COOL_KP" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 917 BYTES = 5 DESCRIPTION = "Value used in outer control loop of cooler. The outer loop examines the temperature difference between goal and actual cooler cold tip temperature, and drives the cooler to a level related to the temperature difference. This value is a gain in the control algorithm." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 96 NAME = "COOL_KI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 923 BYTES = 5 DESCRIPTION = "Gain used in inner control loop of cooler." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 97 NAME = "COOL_OFFSET" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 929 BYTES = 5 DESCRIPTION = "Offset used in inner control loop of cooler." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 98 NAME = "CAL_ON" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 935 BYTES = 5 DESCRIPTION = "Maximum amount of time in seconds that a calibration lamp may remain on before it is powered down by software." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 99 NAME = "CAL_OFF" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 941 BYTES = 5 DESCRIPTION = "Minimum amount of time in seconds that a single calibration lamp must remain off until software allows it to be turned on." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 100 NAME = "CAL_BOTH" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 947 BYTES = 5 DESCRIPTION = "Minimum amount of time in seconds that both VNIR focal plane lamps or both IR focal plane lamps must remain off until software allows either to be turned on." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 101 NAME = "HOP_ON" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 953 BYTES = 5 DESCRIPTION = "Maximum amount of time in seconds that the high output paraffin actuator (HOP) that opens the cover may remain on until software powers it off." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 102 NAME = "COMMENT" DATA_TYPE = CHARACTER START_BYTE = 959 BYTES = 512 DESCRIPTION = "Description of reason for change in current values in data structures." END_OBJECT = COLUMN END_OBJECT = TABLE END_OBJECT = FILE END