PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "2005-12-11, P. Cavender corrected syntax; 2006-09-18, MRO CRISM:HWT line length fix" DATA_SET_ID = "MRO-M-CRISM-4/6-CDR-V1.0" /* The time string in the prouct ID will increment when a new entry is made */ PRODUCT_ID = "CDR6_2_0811260000_DR_J_0" PRODUCT_TYPE = CDR SPACECRAFT_ID = MRO INSTRUMENT_ID = CRISM /* The start time field will increment when a new entry is made */ START_TIME = 2005-09-15T14:00:00 STOP_TIME = NULL /* The start clock count field will increment when a new entry is made */ SPACECRAFT_CLOCK_START_COUNT = "2/811260000" SPACECRAFT_CLOCK_STOP_COUNT = NULL /* The creation time field will increment when a new entry is made */ PRODUCT_CREATION_TIME = 2005-09-15T14:00:00 MRO:SENSOR_ID = "J" PRODUCT_VERSION_ID = "0" /* CRISM Data Structure History File */ /* */ /* The purpose of this file to provide a time history of the active values */ /* in CRISM's onboard data alarm limit and parameter data structures. The */ /* alarm limit data structure defines the subsystem currents, voltages, and */ /* temperatures that trigger generation of an alarm packets. Some of the */ /* alarms trigger safing of subsystems. The parameters data structure */ /* contains constants that control timeout of lamps and coolers and the */ /* cooler control algorithm. Default values are stored in permanent memory */ /* (EEPROM). From time to time these are overwritten via command or by */ /* execution of macros. */ /* */ /* In this file, alarm limts are in raw digital units */ /* */ /* Time spans over which a set of values is applicable are demarcated by */ /* one of four events: specific commands, execution of specific macros, */ /* writing new defaults to EEPROM, or power cycling of the instrument which */ /* causes defaults to become active. */ OBJECT = FILE /* The time string in the table file name will increment upon a new entry */ ^TABLE = "CDR6_2_0811260000_DR_J_0.TAB" RECORD_TYPE = FIXED_LENGTH FILE_RECORDS = 6 OBJECT = TABLE NAME = "CRISM DATA STRUCTURE HISTORY FILE" INTERCHANGE_FORMAT = "ASCII" /* The rows field will increment by one when a new entry is made */ ROWS = 6 COLUMNS = 102 ROW_BYTES = 1144 DESCRIPTION = "CRISM Data Structure History File" OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = SPACECRAFT_CLOCK_START_COUNT DATA_TYPE = CHARACTER UNIT = NULL START_BYTE = 1 BYTES = 10 DESCRIPTION = "SCLK at the start time of the span during which the data structure values are active" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = START_TIME DATA_TYPE = TIME UNIT = UTC START_BYTE = 12 BYTES = 19 DESCRIPTION = "UTC at the start time of the span during which the data structure values are active" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = STATUS DATA_TYPE = CHARACTER START_BYTE = 32 BYTES = 10 DESCRIPTION = "HISTORICAL if the row of values represents values that nave been active in CRISM. PLANNED if the values represent defaults or macro values anticipated to be used. PROPOSED if the values represent anticipated replacements for the defaults or macro values." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 4 NAME = DPU_BOARD_TEMP_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 43 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_0; DPU power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 5 NAME = DPU_BOARD_TEMP_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 49 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_0; DPU power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 6 NAME = DPU_P5_VOLTAGE_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 55 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_1; DPU +5 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 7 NAME = DPU_P5_VOLTAGE_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 61 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_1; DPU +5 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 8 NAME = DPU_P5_CURRENT_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 67 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_3; DPU +5 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 9 NAME = DPU_P5_CURRENT_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 73 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_3; DPU +5 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 10 NAME = SCAN_MOT_CURR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 79 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_4; Scan motor current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 11 NAME = SCAN_MOT_CURR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 85 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_4; Scan motor current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 12 NAME = IR_BOARD_TEMP_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 91 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_0; IR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 13 NAME = IR_BOARD_TEMP_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 97 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_0; IR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 14 NAME = IR_FPU_P12_VOLTAGE_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 103 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_1; IR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 15 NAME = IR_FPU_P12_VOLTAGE_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 109 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_1; IR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 16 NAME = IR_FPU_P7_VOLTAGE_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 115 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_2; IR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 17 NAME = IR_FPU_P7_VOLTAGE_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 121 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_2; IR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 18 NAME = IR_FPU_CURRENT_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 127 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_3; IR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 19 NAME = IR_FPU_CURRENT_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 133 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_3; IR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 20 NAME = HEATER_34_CURRENT_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 139 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_4; heater 3 & 4 current; on cooler radiator and spectrometer housing" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 21 NAME = HEATER_34_CURRENT_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 145 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_4; heater 3 & 4 current; on cooler radiator and spectrometer housing" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 22 NAME = VNIR_BOARD_TEMP_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 151 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_0; VNIR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 23 NAME = VNIR_BOARD_TEMP_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 157 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_0; VNIR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 24 NAME = VNIR_FPU_P12_VOLTAGE_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 163 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_1; VNIR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 25 NAME = VNIR_FPU_P12_VOLTAGE_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 169 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_1; VNIR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 26 NAME = VNIR_FPU_P7_VOLTAGE_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 175 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_2; VNIR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 27 NAME = VNIR_FPU_P7_VOLTAGE_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 181 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_2; VNIR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 28 NAME = VNIR_FPU_CURRENT_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 187 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_3; VNIR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 29 NAME = VNIR_FPU_CURRENT_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 193 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_3; VNIR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 30 NAME = HEATER_12_CURRENT_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 199 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_4; Heater 1 & 2 (on gimbal electronics housing) current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 31 NAME = HEATER_12_CURRENT_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 205 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_4; Heater 1 & 2 (on gimbal electronics housing) current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 32 NAME = COOL_BOARD_TEMP_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 211 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_0; Cooler power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 33 NAME = COOL_BOARD_TEMP_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 217 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_0; Cooler power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 34 NAME = COOL_P15_VOLTAGE_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 223 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_1; Cooler +15 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 35 NAME = COOL_P15_VOLTAGE_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 229 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_1; Cooler +15 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 36 NAME = COOL_CURRENT_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 235 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_3; cooler current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 37 NAME = COOL_CURRENT_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 241 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_3; cooler current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 38 NAME = HOP_HEATER_12_CURR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 247 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_4; HOP heater 1 & 2 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 39 NAME = HOP_HEATER_12_CURR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 253 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_4; HOP heater 1 & 2 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 40 NAME = SHUT_MOTOR_CURR_IR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 259 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_0; Shutter motor current (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 41 NAME = SHUT_MOTOR_CURR_IR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 265 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_0; Shutter motor current (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 42 NAME = IR_DETECTOR_TEMP1_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 271 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_1; IR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 43 NAME = IR_DETECTOR_TEMP1_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 277 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_1; IR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 44 NAME = IR_DETECTOR_TEMP2_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 283 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_2; IR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 45 NAME = IR_DETECTOR_TEMP2_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 289 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_2; IR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 46 NAME = COOLER_TEMP1_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 295 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_3; cooler temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 47 NAME = COOLER_TEMP1_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 301 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_3; cooler temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 48 NAME = COOLER_TEMP2_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 307 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_4; cooler temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 49 NAME = COOLER_TEMP2_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 313 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_4; cooler temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 50 NAME = COOLER_TEMP3_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 319 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_5; cooler temperature 3" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 51 NAME = COOLER_TEMP3_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 325 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_5; cooler temperature 3" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 52 NAME = SHUT_MOTOR_TEMP_IR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 331 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_6; shutter motor temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 53 NAME = SHUT_MOTOR_TEMP_IR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 337 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_6; shutter motor temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 54 NAME = SPHERE_TEMP_IR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 343 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_7; integrating sphere temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 55 NAME = SPHERE_TEMP_IR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 349 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_7; integrating sphere temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 56 NAME = SPIDER_TEMP_IR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 355 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_8; telescope spider temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 57 NAME = SPIDER_TEMP_IR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 361 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_8; telescope spider temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 58 NAME = SPECT_CAVITY_TEMP_IR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 367 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_9; spectral cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 59 NAME = SPECT_CAVITY_TEMP_IR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 373 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_9; spectral cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 60 NAME = OSU_CAVITY_TEMP_IR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 379 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_10; OSU cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 61 NAME = OSU_CAVITY_TEMP_IR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 385 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_10; OSU cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 62 NAME = IR_FPU_BOARD_TEMP_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 391 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_11; IR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 63 NAME = IR_FPU_BOARD_TEMP_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 397 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_11; IR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 64 NAME = IR_SPHERE_CURR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 403 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_12; IR sphere lamp current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 65 NAME = IR_SPHERE_CURR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 409 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_12; IR sphere lamp current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 66 NAME = HOP_TEMP_IR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 415 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_13; HOP temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 67 NAME = HOP_TEMP_IR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 421 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_13; HOP temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 68 NAME = SHUT_MOTOR_CURR_VNIR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 427 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_0; shutter motor current (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 69 NAME = SHUT_MOTOR_CURR_VNIR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 433 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_0; shutter motor current (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 70 NAME = VNIR_DETECTOR_TEMP1_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 439 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_1; VNIR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 71 NAME = VNIR_DETECTOR_TEMP1_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 445 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_1; VNIR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 72 NAME = VNIR_DETECTOR_TEMP2_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 451 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_2; VNIR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 73 NAME = VNIR_DETECTOR_TEMP2_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 457 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_2; VNIR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 74 NAME = TELESCOPE_TEMP_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 463 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_3; telescope temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 75 NAME = TELESCOPE_TEMP_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 469 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_3; telescope temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 76 NAME = OPTICAL_BENCH_TEMP_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 475 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_4; optical bench temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 77 NAME = OPTICAL_BENCH_TEMP_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 481 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_4; optical bench temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 78 NAME = SPIDER_TEMP_VNIR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 487 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_5; telescope spider temp. (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 79 NAME = SPIDER_TEMP_VNIR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 493 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_5; telescope spider temp. (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 80 NAME = SPECT_CAVITY_TEMP_VNIR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 499 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_6; spectral cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 81 NAME = SPECT_CAVITY_TEMP_VNIR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 505 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_6; spectral cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 82 NAME = OSU_CAVITY_TEMP_VNIR_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 511 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_7; OSU cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 83 NAME = OSU_CAVITY_TEMP_VNIR_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 517 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_7; OSU cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 84 NAME = VNIR_FPU_BOARD_TEMP_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 523 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_8; VNIR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 85 NAME = VNIR_FPU_BOARD_TEMP_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 529 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_8; VNIR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 86 NAME = BAFFLETEMP_LO DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 535 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_9; baffle temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 87 NAME = BAFFLETEMP_HI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 541 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_9; baffle temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 88 NAME = COOL_ON DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 547 BYTES = 5 DESCRIPTION = "Time which cooler can remain on before it is shut down by software. 20 seconds allows operation in air without icing. 65535 is forever." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 89 NAME = COOL_OFF DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 553 BYTES = 5 DESCRIPTION = "Time which a single cooler must remain off before it can be powered." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 90 NAME = COOL_SWITCH DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 559 BYTES = 5 DESCRIPTION = "Time which all coolers must remain off before any cooler can be powered. 1800 seconds allows a heat pipe to cease functioning so that before a new cooler is powered, the cooler previously shut down becomes thermally isolated from the detector." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 91 NAME = COOL_MAX DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 565 BYTES = 5 DESCRIPTION = "Maximum valid value of cooler level." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 92 NAME = COOL_ERROR DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 571 BYTES = 5 DESCRIPTION = "Maximum difference between cooler cold tip goal temperature and actual cooler cold tip temperature (in raw counts) at which inner cooler control loop - within in about 10K of goal - is operative." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 93 NAME = COOL_CLAMP DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 577 BYTES = 5 DESCRIPTION = "Value used in inner control loop of cooler. Smallest temperature difference between goal and actual cooler cold tip temperature to feed into control loop." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 94 NAME = COOL_INT DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 583 BYTES = 5 DESCRIPTION = "Value used in inner control loop of cooler. The inner loop integrates the temperature difference between goal and actual cooler cold tip temperature. The integral is what drives how hard the cooler works, i.e. This is the limit to the value of the integral." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 95 NAME = COOL_KP DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 589 BYTES = 5 DESCRIPTION = "Value used in outer control loop of cooler. The outer loop examines the temperature difference between goal and actual cooler cold tip temperature, and drives the cooler to a level related to the temperature difference. This value is a gain in the control algorithm." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 96 NAME = COOL_KI DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 595 BYTES = 5 DESCRIPTION = "Gain used in inner control loop of cooler." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 97 NAME = COOL_OFFSET DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 601 BYTES = 5 DESCRIPTION = "Offset used in inner control loop of cooler." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 98 NAME = CAL_ON DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 607 BYTES = 5 DESCRIPTION = "Maximum amount of time in seconds that a calibration lamp may remain on before it is powered down by software." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 99 NAME = CAL_OFF DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 613 BYTES = 5 DESCRIPTION = "Minimum amount of time in seconds that a single calibration lamp must remain off until software allows it to be turned on." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 100 NAME = CAL_BOTH DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 619 BYTES = 5 DESCRIPTION = "Minimum amount of time in seconds that both VNIR focal plane lamps or both IR focal plane lamps must remain off until software allows either to be turned on." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 101 NAME = HOP_ON DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 625 BYTES = 5 DESCRIPTION = "Maximum amount of time in seconds that the high output paraffin actuator (HOP) that opens the cover may remain on until software powers it off." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 102 NAME = COMMENT DATA_TYPE = CHARACTER START_BYTE = 631 BYTES = 512 DESCRIPTION = "Description of reason for change in current values in data structures." END_OBJECT = COLUMN END_OBJECT = TABLE END_OBJECT = FILE END