PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "2005-12-19, S. Murchie; 2006-09-18, MRO CRISM:HWT line length fix" DATA_SET_ID = "MRO-M-CRISM-4/6-CDR-V1.0" /* The time string in the prouct ID will increment when a new entry is made */ PRODUCT_ID = "CDR6_2_0818985600_DR_J_0" PRODUCT_TYPE = CDR SPACECRAFT_ID = MRO INSTRUMENT_ID = CRISM /* The start time field will increment when a new entry is made */ START_TIME = 2005-12-14T00:00:00 STOP_TIME = NULL /* The start clock count field will increment when a new entry is made */ SPACECRAFT_CLOCK_START_COUNT = "2/0818985600" SPACECRAFT_CLOCK_STOP_COUNT = NULL /* The creation time field will increment when a new entry is made */ PRODUCT_CREATION_TIME = 2005-12-19T14:00:00 MRO:SENSOR_ID = "J" PRODUCT_VERSION_ID = "0" /* CRISM Data Structure History File */ /* */ /* The purpose of this file to provide a time history of the active values */ /* in CRISM's onboard data alarm limit and parameter data structures. The */ /* alarm limit data structure defines the subsystem currents, voltages, and */ /* temperatures that trigger generation of an alarm packets. Some of the */ /* alarms trigger safing of subsystems. The parameters data structure */ /* contains constants that control timeout of lamps and coolers and the */ /* cooler control algorithm. Default values are stored in permanent memory */ /* (EEPROM). From time to time these are overwritten via command or by */ /* execution of macros. */ /* */ /* In this file, alarm limts are in raw digital units */ /* */ /* Time spans over which a set of values is applicable are demarcated by */ /* one of four events: specific commands, execution of specific macros, */ /* writing new defaults to EEPROM, or power cycling of the instrument which */ /* causes defaults to become active. */ OBJECT = FILE /* The time string in the table file name will increment upon a new entry */ ^TABLE = "CDR6_2_0818985600_DR_J_0.TAB" RECORD_TYPE = VARIABLE_LENGTH FILE_RECORDS = 5 OBJECT = TABLE NAME = "CRISM DATA STRUCTURE HISTORY FILE" INTERCHANGE_FORMAT = "ASCII" /* The rows field will increment by one when a new entry is made */ ROWS = 7 COLUMNS = 102 ROW_BYTES = 1146 DESCRIPTION = "CRISM Data Structure History File" OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = "SPACECRAFT_CLOCK_START_COUNT" DATA_TYPE = CHARACTER UNIT = NULL START_BYTE = 1 BYTES = 12 DESCRIPTION = "SCLK at the start time of the span during which the data structure values are active" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = "START_TIME" DATA_TYPE = TIME UNIT = UTC START_BYTE = 14 BYTES = 19 DESCRIPTION = "UTC at the start time of the span during which the data structure values are active" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = "STATUS" DATA_TYPE = CHARACTER START_BYTE = 34 BYTES = 10 DESCRIPTION = "HISTORICAL if the row of values represents values that nave been active in CRISM. PLANNED if the values represent defaults or macro values anticipated to be used. PROPOSED if the values represent anticipated replacements for the defaults or macro values." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 4 NAME = "DPU_BOARD_TEMP_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 45 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_0; DPU power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 5 NAME = "DPU_BOARD_TEMP_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 51 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_0; DPU power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 6 NAME = "DPU_P5_VOLTAGE_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 57 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_1; DPU +5 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 7 NAME = "DPU_P5_VOLTAGE_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 63 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_1; DPU +5 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 8 NAME = "DPU_P5_CURRENT_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 69 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_3; DPU +5 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 9 NAME = "DPU_P5_CURRENT_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 75 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_3; DPU +5 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 10 NAME = "SCAN_MOT_CURR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 81 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item DPU_PWR_4; Scan motor current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 11 NAME = "SCAN_MOT_CURR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 87 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item DPU_PWR_4; Scan motor current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 12 NAME = "IR_BOARD_TEMP_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 93 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_0; IR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 13 NAME = "IR_BOARD_TEMP_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 99 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_0; IR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 14 NAME = "IR_FPU_P12_VOLTAGE_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 105 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_1; IR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 15 NAME = "IR_FPU_P12_VOLTAGE_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 111 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_1; IR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 16 NAME = "IR_FPU_P7_VOLTAGE_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 117 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_2; IR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 17 NAME = "IR_FPU_P7_VOLTAGE_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 123 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_2; IR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 18 NAME = "IR_FPU_CURRENT_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 129 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_3; IR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 19 NAME = "IR_FPU_CURRENT_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 135 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_3; IR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 20 NAME = "HEATER_34_CURRENT_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 141 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_PWR_4; heater 3 & 4 current; on cooler radiator and spectrometer housing" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 21 NAME = "HEATER_34_CURRENT_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 147 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_PWR_4; heater 3 & 4 current; on cooler radiator and spectrometer housing" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 22 NAME = "VNIR_BOARD_TEMP_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 153 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_0; VNIR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 23 NAME = "VNIR_BOARD_TEMP_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 159 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_0; VNIR power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 24 NAME = "VNIR_FPU_P12_VOLTAGE_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 165 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_1; VNIR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 25 NAME = "VNIR_FPU_P12_VOLTAGE_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 171 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_1; VNIR FPU +12 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 26 NAME = "VNIR_FPU_P7_VOLTAGE_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 177 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_2; VNIR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 27 NAME = "VNIR_FPU_P7_VOLTAGE_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 183 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_2; VNIR FPU +7 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 28 NAME = "VNIR_FPU_CURRENT_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 189 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_3; VNIR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 29 NAME = "VNIR_FPU_CURRENT_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 195 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_3; VNIR FPU current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 30 NAME = "HEATER_12_CURRENT_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 201 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_PWR_4; Heater 1 & 2 (on gimbal electronics housing) current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 31 NAME = "HEATER_12_CURRENT_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 207 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_PWR_4; Heater 1 & 2 (on gimbal electronics housing) current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 32 NAME = "COOL_BOARD_TEMP_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 213 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_0; Cooler power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 33 NAME = "COOL_BOARD_TEMP_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 219 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_0; Cooler power board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 34 NAME = "COOL_P15_VOLTAGE_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 225 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_1; Cooler +15 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 35 NAME = "COOL_P15_VOLTAGE_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 231 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_1; Cooler +15 voltage" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 36 NAME = "COOL_CURRENT_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 237 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_3; cooler current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 37 NAME = "COOL_CURRENT_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 243 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_3; cooler current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 38 NAME = "HOP_HEATER_12_CURR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 249 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item COOL_PWR_4; HOP heater 1 & 2 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 39 NAME = "HOP_HEATER_12_CURR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 255 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item COOL_PWR_4; HOP heater 1 & 2 current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 40 NAME = "SHUT_MOTOR_CURR_IR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 261 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_0; Shutter motor current (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 41 NAME = "SHUT_MOTOR_CURR_IR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 267 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_0; Shutter motor current (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 42 NAME = "IR_DETECTOR_TEMP1_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 273 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_1; IR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 43 NAME = "IR_DETECTOR_TEMP1_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 279 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_1; IR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 44 NAME = "IR_DETECTOR_TEMP2_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 285 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_2; IR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 45 NAME = "IR_DETECTOR_TEMP2_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 291 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_2; IR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 46 NAME = "COOLER_TEMP1_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 297 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_3; cooler temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 47 NAME = "COOLER_TEMP1_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 303 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_3; cooler temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 48 NAME = "COOLER_TEMP2_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 309 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_4; cooler temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 49 NAME = "COOLER_TEMP2_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 315 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_4; cooler temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 50 NAME = "COOLER_TEMP3_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 321 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_5; cooler temperature 3" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 51 NAME = "COOLER_TEMP3_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 327 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_5; cooler temperature 3" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 52 NAME = "SHUT_MOTOR_TEMP_IR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 333 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_6; shutter motor temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 53 NAME = "SHUT_MOTOR_TEMP_IR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 339 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_6; shutter motor temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 54 NAME = "SPHERE_TEMP_IR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 345 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_7; integrating sphere temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 55 NAME = "SPHERE_TEMP_IR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 351 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_7; integrating sphere temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 56 NAME = "SPIDER_TEMP_IR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 357 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_8; telescope spider temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 57 NAME = "SPIDER_TEMP_IR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 363 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_8; telescope spider temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 58 NAME = "SPECT_CAVITY_TEMP_IR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 369 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_9; spectral cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 59 NAME = "SPECT_CAVITY_TEMP_IR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 375 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_9; spectral cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 60 NAME = "OSU_CAVITY_TEMP_IR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 381 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_10; OSU cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 61 NAME = "OSU_CAVITY_TEMP_IR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 387 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_10; OSU cavity temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 62 NAME = "IR_FPU_BOARD_TEMP_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 393 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_11; IR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 63 NAME = "IR_FPU_BOARD_TEMP_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 399 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_11; IR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 64 NAME = "IR_SPHERE_CURR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 405 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_12; IR sphere lamp current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 65 NAME = "IR_SPHERE_CURR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 411 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_12; IR sphere lamp current" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 66 NAME = "HOP_TEMP_IR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 417 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item IR_FP_13; HOP temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 67 NAME = "HOP_TEMP_IR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 423 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item IR_FP_13; HOP temperature (IR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 68 NAME = "SHUT_MOTOR_CURR_VNIR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 429 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_0; shutter motor current (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 69 NAME = "SHUT_MOTOR_CURR_VNIR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 435 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_0; shutter motor current (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 70 NAME = "VNIR_DETECTOR_TEMP1_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 441 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_1; VNIR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 71 NAME = "VNIR_DETECTOR_TEMP1_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 447 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_1; VNIR detector temperature 1" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 72 NAME = "VNIR_DETECTOR_TEMP2_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 453 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_2; VNIR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 73 NAME = "VNIR_DETECTOR_TEMP2_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 459 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_2; VNIR detector temperature 2" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 74 NAME = "TELESCOPE_TEMP_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 465 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_3; telescope temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 75 NAME = "TELESCOPE_TEMP_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 471 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_3; telescope temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 76 NAME = "OPTICAL_BENCH_TEMP_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 477 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_4; optical bench temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 77 NAME = "OPTICAL_BENCH_TEMP_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 483 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_4; optical bench temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 78 NAME = "SPIDER_TEMP_VNIR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 489 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_5; telescope spider temp. (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 79 NAME = "SPIDER_TEMP_VNIR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 495 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_5; telescope spider temp. (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 80 NAME = "SPECT_CAVITY_TEMP_VNIR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 501 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_6; spectral cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 81 NAME = "SPECT_CAVITY_TEMP_VNIR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 507 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_6; spectral cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 82 NAME = "OSU_CAVITY_TEMP_VNIR_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 513 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_7; OSU cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 83 NAME = "OSU_CAVITY_TEMP_VNIR_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 519 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_7; OSU cavity temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 84 NAME = "VNIR_FPU_BOARD_TEMP_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 525 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_8; VNIR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 85 NAME = "VNIR_FPU_BOARD_TEMP_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 531 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_8; VNIR FPU board temperature" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 86 NAME = "BAFFLETEMP_LO" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 537 BYTES = 5 DESCRIPTION = "Lower alarm limit for analog housekeeping item VNIR_FP_9; baffle temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 87 NAME = "BAFFLETEMP_HI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 543 BYTES = 5 DESCRIPTION = "Upper alarm limit for analog housekeeping item VNIR_FP_9; baffle temperature (VNIR)" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 88 NAME = "COOL_ON" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 549 BYTES = 5 DESCRIPTION = "Time which cooler can remain on before it is shut down by software. 20 seconds allows operation in air without icing. 65535 is forever." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 89 NAME = "COOL_OFF" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 555 BYTES = 5 DESCRIPTION = "Time which a single cooler must remain off before it can be powered." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 90 NAME = "COOL_SWITCH" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 561 BYTES = 5 DESCRIPTION = "Time which all coolers must remain off before any cooler can be powered. 1800 seconds allows a heat pipe to cease functioning so that before a new cooler is powered, the cooler previously shut down becomes thermally isolated from the detector." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 91 NAME = "COOL_MAX" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 567 BYTES = 5 DESCRIPTION = "Maximum valid value of cooler level." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 92 NAME = "COOL_ERROR" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 573 BYTES = 5 DESCRIPTION = "Maximum difference between cooler cold tip goal temperature and actual cooler cold tip temperature (in raw counts) at which inner cooler control loop - within in about 10K of goal - is operative." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 93 NAME = "COOL_CLAMP" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 579 BYTES = 5 DESCRIPTION = "Value used in inner control loop of cooler. Smallest temperature difference between goal and actual cooler cold tip temperature to feed into control loop." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 94 NAME = "COOL_INT" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 585 BYTES = 5 DESCRIPTION = "Value used in inner control loop of cooler. The inner loop integrates the temperature difference between goal and actual cooler cold tip temperature. The integral is what drives how hard the cooler works, i.e. This is the limit to the value of the integral." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 95 NAME = "COOL_KP" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 591 BYTES = 5 DESCRIPTION = "Value used in outer control loop of cooler. The outer loop examines the temperature difference between goal and actual cooler cold tip temperature, and drives the cooler to a level related to the temperature difference. This value is a gain in the control algorithm." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 96 NAME = "COOL_KI" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 597 BYTES = 5 DESCRIPTION = "Gain used in inner control loop of cooler." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 97 NAME = "COOL_OFFSET" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 603 BYTES = 5 DESCRIPTION = "Offset used in inner control loop of cooler." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 98 NAME = "CAL_ON" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 609 BYTES = 5 DESCRIPTION = "Maximum amount of time in seconds that a calibration lamp may remain on before it is powered down by software." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 99 NAME = "CAL_OFF" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 615 BYTES = 5 DESCRIPTION = "Minimum amount of time in seconds that a single calibration lamp must remain off until software allows it to be turned on." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 100 NAME = "CAL_BOTH" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 621 BYTES = 5 DESCRIPTION = "Minimum amount of time in seconds that both VNIR focal plane lamps or both IR focal plane lamps must remain off until software allows either to be turned on." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 101 NAME = "HOP_ON" DATA_TYPE = ASCII_INTEGER UNIT = NULL START_BYTE = 627 BYTES = 5 DESCRIPTION = "Maximum amount of time in seconds that the high output paraffin actuator (HOP) that opens the cover may remain on until software powers it off." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 102 NAME = "COMMENT" DATA_TYPE = CHARACTER START_BYTE = 633 BYTES = 512 DESCRIPTION = "Description of reason for change in current values in data structures." END_OBJECT = COLUMN END_OBJECT = TABLE END_OBJECT = FILE END