<?xml version="1.0" encoding="UTF-8"?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1J00.sch"
  schematypens="http://purl.oclc.org/dsdl/schematron"?>
<Product_Observational xmlns="http://pds.nasa.gov/pds4/pds/v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://pds.nasa.gov/pds4/pds/v1    https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1J00.xsd">

  <Identification_Area>
    <logical_identifier>urn:nasa:pds:msl_chemcam_derived:calib:ccam_calibration_compositions</logical_identifier>
    <version_id>1.0</version_id>
    <title>Multivariant Oxides Composition of Chemcam Calibration samples
           data used in the various ChemCam Calibration data sets.</title>
    <information_model_version>1.19.0.0</information_model_version>
    <product_class>Product_Observational</product_class>
    <Modification_History>
      <Modification_Detail>
         <modification_date>2024-04-30</modification_date>
         <version_id>1.0</version_id>
          <description>Initial PDS4 version</description>
      </Modification_Detail>
    </Modification_History>
  </Identification_Area>
  <Observation_Area>
    <Time_Coordinates>
      <start_date_time xsi:nil="true" nilReason="inapplicable"/>
      <stop_date_time xsi:nil="true" nilReason="inapplicable"/>
    </Time_Coordinates>
    <Primary_Result_Summary>
      <purpose>Calibration</purpose>
      <processing_level>Calibrated</processing_level>
    </Primary_Result_Summary>
    <Investigation_Area>
      <name>Mars Science Laboratory</name>
      <type>Mission</type>
      <Internal_Reference>
        <lid_reference>urn:nasa:pds:context:investigation:mission.mars_science_laboratory</lid_reference>
        <reference_type>data_to_investigation</reference_type>
      </Internal_Reference>
    </Investigation_Area>
    <Observing_System>
      <Observing_System_Component>
        <name>Mars Science Laboratory</name>
        <type>Host</type>
        <Internal_Reference>
          <lid_reference>urn:nasa:pds:context:instrument_host:spacecraft.msl</lid_reference>
          <reference_type>is_instrument_host</reference_type>
        </Internal_Reference>
      </Observing_System_Component>
      <Observing_System_Component>
        <name>CHEMISTRY CAMERA LASER INDUCED BREAKDOWN SPECTROMETER</name>
        <type>Instrument</type>
        <Internal_Reference>
          <lid_reference>urn:nasa:pds:context:instrument:chemcam_libs.msl</lid_reference>
          <reference_type>is_instrument</reference_type>
        </Internal_Reference>
      </Observing_System_Component>
    </Observing_System>
    <Target_Identification>
      <name>Mars</name>
      <type>Planet</type>
      <Internal_Reference>
        <lid_reference>urn:nasa:pds:context:target:planet.mars</lid_reference>
        <reference_type>data_to_target</reference_type>
      </Internal_Reference>
    </Target_Identification>
  </Observation_Area>
  <File_Area_Observational>
    <File>
      <file_name>ccam_calibration_compositions.csv</file_name>
      <creation_date_time>2023-02-07T14:52:00</creation_date_time>
    </File>

    <Header>
      <offset unit="byte">0</offset>
      <object_length unit="byte">170</object_length>
      <parsing_standard_id>7-Bit ASCII Text</parsing_standard_id>
          <description>The header records in this file identify the data in each field. The last three columns identify in which calibration data set the sample is used.</description>
    </Header>

    <Table_Delimited>
      <local_identifier>TABLE</local_identifier>
      <offset unit="byte">170</offset>
      <parsing_standard_id>PDS DSV 1</parsing_standard_id>
          <description>This data product is a ChemCam
    Multivariant Oxides Composition Table for data used in the MSL LIBS
    calibration.</description>
      <records>744</records>
      <record_delimiter>Carriage-Return Line-Feed</record_delimiter>
      <field_delimiter>Comma</field_delimiter>
      <Record_Delimited>
        <fields>16</fields>
        <groups>0</groups>
        <Field_Delimited>
          <name>TARGET_NAME</name>
          <field_number>1</field_number>
          <data_type>ASCII_String</data_type>
          <maximum_field_length unit="byte">20</maximum_field_length>
          <description>Name of the target or sample</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>SPECTRUM_NAME</name>
          <field_number>2</field_number>
          <data_type>ASCII_String</data_type>
          <maximum_field_length unit="byte">20</maximum_field_length>
          <description>Target name in filename</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>SAMPLE_NAME</name>
          <field_number>3</field_number>
          <data_type>ASCII_String</data_type>
          <maximum_field_length unit="byte">20</maximum_field_length>
          <description>Official Sample Name</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>SIO2</name>
          <field_number>4</field_number>
          <data_type>ASCII_Real</data_type>
          <maximum_field_length unit="byte">12</maximum_field_length>
          <unit>wt%</unit>
          <description>Predicted composition SiO2</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>TIO2</name>
          <field_number>5</field_number>
          <data_type>ASCII_Real</data_type>
          <maximum_field_length unit="byte">12</maximum_field_length>
          <unit>wt%</unit>
          <description>Predicted composition TiO2</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>AL203</name>
          <field_number>6</field_number>
          <data_type>ASCII_Real</data_type>
          <maximum_field_length unit="byte">12</maximum_field_length>
          <unit>wt%</unit>
          <description>Predicted composition Al203</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>FEOT</name>
          <field_number>7</field_number>
          <data_type>ASCII_Real</data_type>
          <maximum_field_length unit="byte">12</maximum_field_length>
          <unit>wt%</unit>
          <description>Predicted composition FeOT</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>MnO</name>
          <field_number>8</field_number>
          <data_type>ASCII_Real</data_type>
          <maximum_field_length unit="byte">12</maximum_field_length>
          <unit>wt%</unit>
          <description>Predicted composition MnO</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>MGO</name>
          <field_number>9</field_number>
          <data_type>ASCII_Real</data_type>
          <maximum_field_length unit="byte">12</maximum_field_length>
          <unit>wt%</unit>
          <description>Predicted composition MgO</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>CAO</name>
          <field_number>10</field_number>
          <data_type>ASCII_Real</data_type>
          <maximum_field_length unit="byte">12</maximum_field_length>
          <unit>wt%</unit>
          <description>Predicted composition CaO</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>NA20</name>
          <field_number>11</field_number>
          <data_type>ASCII_Real</data_type>
          <maximum_field_length unit="byte">12</maximum_field_length>
          <unit>wt%</unit>
          <description>Predicted composition Na20</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>K20</name>
          <field_number>12</field_number>
          <data_type>ASCII_Real</data_type>
          <maximum_field_length unit="byte">12</maximum_field_length>
          <unit>wt%</unit>
          <description>Predicted composition K2O</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>MOC_TOTAL</name>
          <field_number>13</field_number>
          <data_type>ASCII_Real</data_type>
          <maximum_field_length unit="byte">12</maximum_field_length>
          <unit>wt%</unit>
          <description>The sum of the major oxides</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>CALIB_2015</name>
          <field_number>14</field_number>
          <data_type>ASCII_Integer</data_type>
          <maximum_field_length unit="byte">1</maximum_field_length>
          <unit>wt%</unit>
          <description>Used in 2015 calibration data set
                            0 = NO 1 = Yes</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>CALIB_2021_MN</name>
          <field_number>15</field_number>
          <data_type>ASCII_Integer</data_type>
          <maximum_field_length unit="byte">1</maximum_field_length>
          <unit>wt%</unit>
          <description>Used in 2021 Mn calibration data set
                            0 = NO 1 = Yes</description>
        </Field_Delimited>
        <Field_Delimited>
          <name>CALIB_2022_Li</name>
          <field_number>16</field_number>
          <data_type>ASCII_Integer</data_type>
          <maximum_field_length unit="byte">1</maximum_field_length>
          <unit>wt%</unit>
          <description>Used in 2022 Li calibration data set
                               0 = NO 1 = Yes</description>
        </Field_Delimited>
       </Record_Delimited>
    </Table_Delimited>
  </File_Area_Observational>
  <File_Area_Observational_Supplemental>
    <File>
      <file_name>ccam_calibration_compositions.lbl</file_name>
    </File>
    <Stream_Text>
      <offset unit="byte">0</offset>
      <parsing_standard_id>PDS3</parsing_standard_id>
      <description>Original PDS3 label</description>
      <record_delimiter>Carriage-Return Line-Feed</record_delimiter>
    </Stream_Text>
  </File_Area_Observational_Supplemental>
</Product_Observational>