2002-11-08T17:27:52.000 \header System = GRS Author = mward Institution = UofAz Start_time = 11/08/02 16:00 Stop_time = 11/09/02 20:00 Send_time = Fri Nov 08 17:27:52 GMT 2002 \text Purpose: Change the GRS EEPROM sequence 1B to use the PCON register to control the OS secondary heater (with the GPA heater #3 and MR Operational heater on full) at Expected result: The GRS EEPROM sequence will be replaced. Why it is needed: To avoid a too cold condition for the outer stage, the mounting ring, and the Commands to be sent: /home/mward/Deployed_1/c01grs_s01b_startup_htr_c_7.bfl 3101, immediate, CHG_SEQ, 96, B-1, 8 0: immediate, CHG_PARAM, AUTO_BIG_BURST_ON, 0, 0 1: immediate, CHG_PARAM, AUTO_BURST_ON, 0, 0 2: immediate, CHG_ANALOG, CEB_OS_TEMP_A, OUT_OF_RANGE, 0, 0 3: immediate, CHG_ANALOG, CEB_OS_TEMP_A, COLLECTION, 3, 0 4: immediate, CHG_ANALOG, CEB_OS_TEMP_A, LESS_COMPARE_VALUE, 3182, 0 5: immediate, CHG_ANALOG, CEB_OS_TEMP_A, GREATER_COMPARE_VALUE, 3381, 0 6: + 0-1 , EXEC_SEQ, 45, 1, 0 7: + 0-4 , EXEC_SEQ, 41, 0, 0