2003-06-06T20:13:08.000 \header System = GRS Author = mward Institution = UofAz Start_time = 06/06/03 20:00 Stop_time = 06/09/03 19:00 Send_time = Fri Jun 06 20:13:08 GMT 2003 \text Purpose: Stop the current duty cycle control of the OS Secondary heater and start it on Expected result: The duty cycle control will operate using EEPROM sequences 37b, 38b, 39b, and Why it is needed: To avoid a delayed-command issue that locks the OS Secondary heater full off or locks the duty cycle on without a temperature control, and to perform a Commands to be sent: /home/mward/Deployed_1/c01grs_os_s_a_htr_duty_delta_1.bcf 2027, immediate, CHG_ANALOG, CEB_OS_TEMP_B, COMPARE_SETTING, 0 2400, immediate, CHG_ANALOG, CEB_AGND_SPARE2, COMPARE_SETTING, 0 2349, immediate, CHG_ANALOG, CEB_OS_TEMP_A, COMPARE_SETTING, 0 1139, + 0-1 , EXEC_SEQ, 39, 1 2029, + 0-2 , CHG_ANALOG, CEB_OS_TEMP_B, COMPARE_SETTING, 2 1041, + 0-6 , EXEC_SEQ, 41, 0