2009-12-18T18:56:26.000 \header System = GRS Author = cfellows Institution = UofAz Start_time = 12/21/09 16:00 Stop_time = 12/23/09 00:20 Send_time = Fri Dec 18 18:56:26 GMT 2009 \text Purpose: Shut down pulser transmission to minimize bandwidth. Expected result: GRS will stop sending pulser packet Why it is needed: With Gamma subsystem HV off the pulser packets are empty and simply taking Commands to be sent: /export/home/cfellows/commands/c01grs_pulser_tran_disable.bcf 2010, immediate, CHG_CLCT, Pulser, OFF 1041, + 20 , EXEC_SEQ, 41, 0  2009-12-18T19:00:04.000 \header System = GRS Author = cfellows Institution = UofAz Start_time = 12/21/09 16:00 Stop_time = 12/23/09 00:20 Send_time = Fri Dec 18 19:00:04 GMT 2009 \text Purpose: Change OS heater setpoints to -98C. Place MR under temperature control. Expected result: OS temperature will drop to -98, MR will be placed under temperature control Why it is needed: Modified Return to science left instrument in slightly different configuration than nominal return to science that requires more power than is necessary Commands to be sent: /export/home/cfellows/commands/c01grs_saf_mod_htr_cleanup.bcf 1325, immediate, OP_HTR, OFF 2082, immediate, CHG_ANALOG, CEB_MNT_RNG_TEMP_A, COMPARE_SETTING, 0 2805, immediate, CHG_ANALOG, CEB_MNT_RNG_TEMP_A, LESS_COMPARE_VALUE, 2552 2491, immediate, CHG_ANALOG, CEB_MNT_RNG_TEMP_A, GREATER_COMPARE_VALUE, 2488, immediate, CHG_ANALOG, CEB_MNT_RNG_TEMP_A, OUT_OF_RANGE, 2 1023, + 20 , EXEC_SEQ, 23, 0 2349, + 20 , CHG_ANALOG, CEB_OS_TEMP_A, COMPARE_SETTING, 0 1305, + 40 , ANNEAL_PWR_CNTRL, 1, OFF 2749, + 60 , CHG_ANALOG, CEB_OS_TEMP_A, LESS_COMPARE_VALUE, 2913 2500, + 60 , CHG_ANALOG, CEB_OS_TEMP_A, GREATER_COMPARE_VALUE, 2914 1045, + 80 , EXEC_SEQ, 45, 0 1041, + 100 , EXEC_SEQ, 41, 0