OBJECT = COLUMN COLUMN_NUMBER = 12 NAME = "CURRENT TIP" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 1 BYTES = 1 DESCRIPTION = "Current tip (0-7)." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 13 NAME = "INITIAL VAP" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 2 BYTES = 1 DESCRIPTION = "Initial Vap (volts = value/25.5)." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 14 NAME = "PAD 1" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 3 BYTES = 2 DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 15 NAME = "INITIAL FREQUENCY IN HZ" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 5 BYTES = 4 DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 16 NAME = "VAP VALUES PASS 1" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 9 BYTES = 9 ITEMS = 9 ITEM_BYTES = 1 DESCRIPTION = "Vap values for pass1, phases 0, 20, ..., 160 deg (volts = value/25.5)." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 17 NAME = "VAP VALUES PASS 2" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 18 BYTES = 9 ITEMS = 9 ITEM_BYTES = 1 DESCRIPTION = "Vap values for pass2, phases 180, 200, ..., 340 deg (volts = value/25.5)." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 18 NAME = "PAD 2" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 27 BYTES = 2 DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 19 NAME = "CENTER FREQUENCY PASS 1" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 29 BYTES = 36 ITEMS = 9 ITEM_BYTES = 4 DESCRIPTION = "Vap values for pass 1, phases 0, 20, ..., 160 deg (volts = value/25.5)." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 20 NAME = "CENTER FREQUENCY PASS 2" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 65 BYTES = 36 ITEMS = 9 ITEM_BYTES = 4 DESCRIPTION = "Vap values for pass 2, phases 180, 200, ..., 340 deg (volts = value/25.5)." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 21 NAME = "LOWEST VAP" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 101 BYTES = 1 DESCRIPTION = "Lowest Vap found in this test (volts = value/25.5)." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 22 NAME = "NEW PHASE" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 102 BYTES = 1 DESCRIPTION = "Phase where lowest Vap found (0=0 deg, 1=20, ...)." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 23 NAME = "NEW LOWEST VAP" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 103 BYTES = 1 DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 24 NAME = "PAD 3" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 104 BYTES = 1 DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 25 NAME = "NEW AMPLITUDE IN MV" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 105 BYTES = 4 DESCRIPTION = "New amplitude (signed - if negative, add 180 deg to phase." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 26 NAME = "NEW CENTER FREQUENCY IN HZ" DATA_TYPE = MSB_UNSIGNED_INTEGER START_BYTE = 109 BYTES = 4 DESCRIPTION = "New center frequency." END_OBJECT = COLUMN