PDS_VERSION_ID = PDS3 LABEL_REVISION_NOTE = "2008-04-14, Initial" /* File Characteristics */ RECORD_TYPE = FIXED_LENGTH RECORD_BYTES = 198 FILE_RECORDS = 2648 /*Pointers to Data Objects */ ^WCL_HEADER_TABLE = ("ws032c0pt___00___13980000w0.tab",2) ^PT_CALIBRATION_TABLE = ("ws032c0pt___00___13980000w0.tab",17) ^WCL_EVENT_TABLE = ("ws032c0pt___00___13980000w0.tab",24) ^WCL_DATA_HEADER_TABLE = ("ws032c0pt___00___13980000w0.tab",27) ^WCL_DATA_TABLE = ("ws032c0pt___00___13980000w0.tab",30) /* Identification */ DATA_SET_ID = "PHX-M-MECA-4-NIRDR-V1.0" PRODUCT_ID = "WS032C0PT___00___13980000W0" PRODUCT_VERSION_ID = "V1.0" PRODUCT_TYPE = "MECA_WCL_PT" RELEASE_ID = "0002" INSTRUMENT_HOST_NAME = "PHOENIX" INSTRUMENT_NAME = "MECA WET CHEMISTRY LABORATORY" INSTRUMENT_HOST_ID = PHX TARGET_NAME = "MARS" INSTRUMENT_ID = "MECA_WCL" INSTRUMENT_MODE_ID = "PT" MISSION_NAME = "PHOENIX" OPS_TOKEN = 16#13980000# OPS_TOKEN_ACTIVITY = 16#00001398# OPS_TOKEN_PAYLOAD = 16#00000000# OPS_TOKEN_COMMAND = 16#00000000# /* Time information */ MISSION_PHASE_NAME = "PRIMARY MISSION" SPACECRAFT_CLOCK_START_COUNT = "899041649.836" SPACECRAFT_CLOCK_STOP_COUNT = "899050659.344" START_TIME = 2008-06-27T13:46:20.463 STOP_TIME = 2008-06-27T16:16:28.523 EARTH_RECEIVED_START_TIME = "UNK" EARTH_RECEIVED_STOP_TIME = "UNK" PLANET_DAY_NUMBER = 32 LOCAL_TRUE_SOLAR_TIME = "09:51:16" PRODUCT_CREATION_TIME = 2008-12-20T00:01:29.910 /* Data Object Definitions */ OBJECT = WCL_HEADER_TABLE COLUMNS = 2 INTERCHANGE_FORMAT = ASCII ROW_BYTES = 93 ROWS = 13 ROW_SUFFIX_BYTES = 105 DESCRIPTION = "Two column PT header table with 93 bytes of data followed by 105 spare bytes, the last two of which are the characters." OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = "HEADER FIELD NAME" DATA_TYPE = CHARACTER START_BYTE = 2 BYTES = 25 END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = "HEADER FIELD VALUE" DATA_TYPE = CHARACTER START_BYTE = 30 BYTES = 62 END_OBJECT = COLUMN END_OBJECT = WCL_HEADER_TABLE OBJECT = PT_CALIBRATION_TABLE COLUMNS = 4 INTERCHANGE_FORMAT = ASCII ROW_BYTES = 49 ROW_SUFFIX_BYTES = 149 ROWS = 5 DESCRIPTION = "Table of values used to convert sensor DNs to physical units. Pressures in mB, temperature in C. There are 49 bytes of data in this table followed by 149 spare bytes, the last two of which are the characters." OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = "SENSOR_NAME" DATA_TYPE = CHARACTER START_BYTE = 2 BYTES = 15 DESCRIPTION = "Name of sensor reading to be converted." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = "SLOPE_VALUE" DATA_TYPE = ASCII_REAL START_BYTE = 19 BYTES = 11 DESCRIPTION = "SLOPE value used in conversion equation P(mbar) = SLOPE*DN + INTERCEPT for pressure or T(degC) = SLOPE*DN + INTERCEPT temperature." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = "INTERCEPT_VALUE" DATA_TYPE = ASCII_REAL START_BYTE = 31 BYTES = 11 DESCRIPTION = "INTERCEPT value used in conversion equation P(mbar) = SLOPE*DN + INTERCEPT for pressure or T(degC) = SLOPE*DN + INTERCEPT for temperature." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 4 NAME = "PHYSICAL_UNIT" DATA_TYPE = CHARACTER START_BYTE = 44 BYTES = 5 DESCRIPTION = "physical unit of calibrated value" END_OBJECT = COLUMN END_OBJECT = PT_CALIBRATION_TABLE OBJECT = WCL_EVENT_TABLE COLUMNS = 3 INTERCHANGE_FORMAT = ASCII ROW_BYTES = 149 ROW_SUFFIX_BYTES = 49 ROWS = 1 DESCRIPTION = "Three column PT events table." OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = "EVENT_NAME" DATA_TYPE = ASCII_REAL START_BYTE = 2 BYTES = 20 DESCRIPTION = "Name of event - solution dispense, drawer open, drawer close, reagent release" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = "CMD_TIME" DATA_TYPE = ASCII_REAL START_BYTE = 24 BYTES = 14 MISSING_CONSTANT = 99999999999 DESCRIPTION = "SCLK time the event was commanded by Phoenix" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = "EVENT_NOTES" DATA_TYPE = CHARACTER START_BYTE = 40 BYTES = 108 DESCRIPTION = "Description of the event." END_OBJECT = COLUMN END_OBJECT = WCL_EVENT_TABLE OBJECT = WCL_DATA_HEADER_TABLE COLUMNS = 9 INTERCHANGE_FORMAT = ASCII ROW_BYTES = 113 ROWS = 1 ROW_SUFFIX_BYTES = 85 DESCRIPTION = "Nine column pressure, temperature and heater state data header table with 113 bytes of data followed by 85 spare bytes, the last two of which are the characters." OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = "TIME_HEADER" DATA_TYPE = ASCII_REAL START_BYTE = 2 BYTES = 4 END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = "PRESSURE_HEADER" DATA_TYPE = ASCII_REAL START_BYTE = 9 BYTES = 8 END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = "T_BEAKER_HEADER" DATA_TYPE = ASCII_REAL START_BYTE = 20 BYTES = 8 END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 4 NAME = "T_TANK_HEADER" DATA_TYPE = ASCII_REAL START_BYTE = 31 BYTES = 6 END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 5 NAME = "T_DRAWER_HEADER" DATA_TYPE = ASCII_REAL START_BYTE = 40 BYTES = 8 END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 6 NAME = "T_STAGE_HEADER" DATA_TYPE = ASCII_REAL START_BYTE = 51 BYTES = 7 END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 7 NAME = "BEAKER_HTR_STATE_HEADER" DATA_TYPE = ASCII_REAL START_BYTE = 61 BYTES = 16 END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 8 NAME = "TANK_HTR_STATE_HEADER" DATA_TYPE = ASCII_REAL START_BYTE = 80 BYTES = 14 END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 9 NAME = "DRAWER_HTR_STATE_HEADER" DATA_TYPE = ASCII_REAL START_BYTE = 97 BYTES = 16 END_OBJECT = COLUMN END_OBJECT = WCL_DATA_HEADER_TABLE OBJECT = WCL_DATA_TABLE COLUMNS = 9 INTERCHANGE_FORMAT = ASCII ROW_BYTES = 81 ROWS = 2619 ROW_SUFFIX_BYTES = 117 DESCRIPTION = "Nine column pressure and temperature data table with 79 bytes of data followed by 119 spare bytes, the last two of which are the characters." OBJECT = COLUMN COLUMN_NUMBER = 1 NAME = "TIME" DATA_TYPE = ASCII_REAL START_BYTE = 1 BYTES = 14 DESCRIPTION = "series of SCLK read times" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 2 NAME = "PRESSURE" DATA_TYPE = ASCII_REAL START_BYTE = 16 BYTES = 11 DESCRIPTION = "series of pressure measurements for the selected WCL cell in millibars." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 3 NAME = "T_BEAKER" DATA_TYPE = ASCII_REAL START_BYTE = 28 BYTES = 11 DESCRIPTION = "series of beaker temperature measurements for the selected WCL cell in C." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 4 NAME = "T_TANK" DATA_TYPE = ASCII_REAL START_BYTE = 40 BYTES = 11 DESCRIPTION = "series of tank temperature measurements for the selected WCL cell in C." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 5 NAME = "T_DRAWER" DATA_TYPE = ASCII_REAL START_BYTE = 52 BYTES = 11 DESCRIPTION = "series of drawer temperature measurements for the selected WCL cell in C." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 6 NAME = "T_STAGE" DATA_TYPE = ASCII_REAL START_BYTE = 64 BYTES = 11 DESCRIPTION = "series of microscopy stage temperature measurements." END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 7 NAME = "BEAKER_HEATER_STATE" DATA_TYPE = BOOLEAN START_BYTE = 76 BYTES = 1 DESCRIPTION = "State of the beaker heater. 0-heater off, 1-heater on" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 8 NAME = "TANK_HEATER_STATE" DATA_TYPE = BOOLEAN START_BYTE = 78 BYTES = 1 DESCRIPTION = "State of the tank heater. 0-heater off, 1-heater on" END_OBJECT = COLUMN OBJECT = COLUMN COLUMN_NUMBER = 9 NAME = "DRAWER_HEATER_STATE" DATA_TYPE = BOOLEAN START_BYTE = 80 BYTES = 1 DESCRIPTION = "State of the drawer heater. 0-heater off, 1-heater on" END_OBJECT = COLUMN END_OBJECT = WCL_DATA_TABLE END