TEGA EXPERIMENT DATA RECORD SOFTWARE INTERFACE SPECIFICATION
Version 1.3
October 8, 2008
JPL PH 274-304
D-33227
|
Prepared by:
Susan Slavney PDS Geosciences Node
|
Karl Harshman PhoenixTEGA Team
|
|
Approved by:
William V. Boynton Instrument Co-Investigator, TEGA
|
Leslie Tamppari Phoenix Project Scientist
|
|
Raymond E. Arvidson Director, PDS Geosciences Node
|
Edwin Grayzeck Project Manager, Planetary Data System
|
|
Date |
Description |
Sections affected |
Version |
|
09/7/05 |
Initial Draft |
All |
0.1 |
|
04/3/06 |
Draft |
All |
1.0 |
|
08/31/06 |
Draft |
Removed all RDR references |
1.0a |
|
09/19/06 |
Draft |
Section 5 - Added Data Products |
1.0b |
|
09/28/06 |
Draft |
Section 4.1 - Added Mass Hopping description |
1.0c |
|
09/28/06 |
Draft |
Section 4.4 Standards Used in Generating Data Products (except Coordinate Systems) |
1.0d |
|
3/22/07 |
Draft |
Section 4.3.1 Labeling and Identification - added Table 4-6, TEGA-Specific EDR File Names |
1.1 |
|
3/22/07 |
Draft |
Section 4.3.4 Coordinate System - added standard text supplied by MIPL |
1.1 |
|
3/22/07 |
Draft |
Section 4.3.6, Command Sequence Tracking - added this section to explain TEGA use of OPS_TOKEN keyword; also changed DATA_PRODUCT_TAG to OPS_TOKEN in sample labels |
1.1 |
|
3/23/07 |
Draft |
Table 4-6, TEGA-Specific EDR File Names. Fixed the TBD at location c to be a U. |
1.2 |
|
3/23/07 |
Draft |
Section 4.3.6, Command Sequence Tracking - removed the TBD. TEGA will set bits 17-21 to 0. |
1.2 |
|
10/08/08 |
Draft |
Table 4-3 and Sections 4.1. 5.1.1, 5.2.1, 5.3.1, 5.4.1, 5.5.1, and 5.6.1 - Revision to add Activities folder based on change to the Archive Volume SIS |
1.3 |
TBD LOG
|
Date |
Description |
Section |
|
|
|
|
1. Purpose and Scope of Document.................................................................................... 1
2. Applicable Documents.................................................................................................... 1
3. Relationships with Other Interfaces................................................................................ 1
4. Data Product Characteristics and Environment.............................................................. 2
4.0 Instrument Overview................................................................................................. 2
4.1 EDR and RDR Data Product Overview................................................................... 3
4.2 Data Processing......................................................................................................... 3
4.2.1 Data Processing Level........................................................................................ 3
4.2.2 Data Product Generation.................................................................................... 3
4.2.3 Data Flow........................................................................................................... 9
4.3 Standards Used in Generating Data Products.......................................................... 9
4.3.1 Labeling and Identification................................................................................ 9
4.3.2 PDS Standards................................................................................................. 12
4.3.3 Time Standards................................................................................................. 12
4.3.4 Coordinate Systems.......................................................................................... 12
4.3.5 Data Storage Conventions................................................................................ 13
4.3.6 Command Sequence Tracking.......................................................................... 13
4.4 Data Validation and Peer Review........................................................................... 13
5. Detailed Data Product Specifications........................................................................... 14
5.0 TEGA Labels........................................................................................................... 14
5.1 TEGA Engineering Data EDR (ENGEDR)............................................................ 14
5.1.1 Data Product Structure and Organization........................................................ 14
5.1.2 Data Format...................................................................................................... 15
5.2 TEGA SC Oven Heating Data EDR (SCEDR)...................................................... 15
5.2.1 Data Product Structure and Organization........................................................ 15
5.2.2 Data Format...................................................................................................... 16
5.3 TEGA EGA EDR (EGAEDR)............................................................................... 17
5.3.1 Data Product Structure and Organization........................................................ 17
5.3.2 Data Format...................................................................................................... 17
5.4 TEGA EGA Mass Hopping Counts EDR (EGHEDR).......................................... 19
5.4.1 Data Product Structure and Organization........................................................ 19
5.4.2 Data Format...................................................................................................... 19
5.5 TEGA LED EDR (LEDEDR)................................................................................ 21
5.5.1 Data Product Structure and Organization........................................................ 21
5.5.2 Data Format...................................................................................................... 21
5.6 TEGA Message Log EDR (MSGEDR).................................................................. 22
5.6.1 Data Product Structure and Organization........................................................ 22
5.6.2 Data Format...................................................................................................... 22
6. Applicable Software...................................................................................................... 23
6.0 Utility Programs...................................................................................................... 23
6.1 Applicable PDS Software Tools.............................................................................. 23
6.2 Software Distribution and Update Procedures....................................................... 24
7. Appendices.................................................................................................................... 25
7.0 Definitions of Data Processing Levels.................................................................... 25
7.1 Columns in TEGA Data Products........................................................................... 26
7.2 Example ENGEDR PDS Label............................................................................... 28
7.3 Example SCEDR PDS Label.................................................................................. 88
7.4 Example EGAEDR PDS Label............................................................................... 89
7.5 Example EGHEDR PDS Label............................................................................... 90
7.6 Example LEDEDR PDS Label............................................................................... 91
7.7 Example MSGEDR PDS Label.............................................................................. 93
7.8 TEGA Container Format Files................................................................................ 96
FIGURES AND TABLES
Table 4‑1 TEGA Standard Data Products. 3
Figure 4.1 TEGA_tl data flow diagram.5
Figure 4.2 TEGA Database Ingest data flow diagram.. 6
Table 4‑2 TEGA Engineering Parameters. 7
Table 4‑3 TEGA EDR Data Volume. 9
Table 4‑4 File Naming Template. 10
Table 4‑5 Detailed description of product name components. 10
Table 4‑6 TEGA-specific EDR file names. 11
Table 7‑1 Data Processing Levels. 25
Table 7‑2 Columns in TEGA Data Products. 26
|
BCE |
Bench Checkout Equipment |
|
PEB |
Payload Electronics Box |
|
CODMAC |
Committee on Data Management and Computation |
|
CCSDS |
Spacecraft Data Systems |
|
CHDO |
Compressed Header Data Object |
|
DN |
Digital Number |
|
DSN |
Deep Space Network |
|
EDR |
Experiment Data Record |
|
EGA |
Evolved Gas Analyzer |
|
HTML |
HyperText Markup Language |
|
ICD |
Interface Control Document |
|
JPL |
Jet Propulsion Laboratory |
|
NSSDC |
National Space Science Data Center |
|
PAWG |
Phoenix Archive Working Group |
|
PDS |
Planetary Data System |
|
PECM |
Power Emission Control Module |
|
RDR |
Reduced Data Record |
|
SC |
Scanning Calorimeter |
|
SFDU |
Standard Format Data Unit |
|
SIS |
Software Interface Specification |
|
SOC |
Science Operations Center |
|
SOPC |
Spacecraft Operations Processing Computer |
|
TA |
Thermal Analyzer |
|
TBD |
To Be Determined |
|
TBW |
To Be Written |
|
TDS |
Telemetry Data System |
|
TEGA |
Thermal and Evolved Gas Analyzer |
|
UA |
University of Arizona |
The purpose of this document is to provide users of TEGA Experiment Data Record (EDR) products with a detailed description of the products and a description of how they are generated, including data sources and destinations. The TEGA EDR data products are made up of six un-calibrated data types including, thermal analyzer data, evolved gas analyzer data, evolved gas analyzer mass hopping data, oven fill data, instrument engineering data, and instrument system message log data.
The document is intended to provide enough information to enable users to read and understand the data products. The users for whom this document is intended are the scientists who will analyze the data, including those associated with the Phoenix Project and those in the general planetary science community.
1. Planetary Data System Standards Reference, JPL D-7669 part 2, version 3.7, March 20, 2006.
2. Phoenix Project Archive Generation, Validation and Transfer Plan, JPL D-29392, Rev. 1.0, December 20, 2004.
3. Planetary Data System Archive Preparation Guide, version 0.050503, May 3, 2005.
4. Mars Exploration Program Data Management Plan, Arvidson et al., Rev. 3.0, March 20, 2002.
5. Phoenix TEGA Team and PDS Geosciences Node Interface Control Document (ICD), Version 1.1, July 11, 2005.
6. Phoenix SOC - Instrument Team - PDS Interface Control Document (ICD), JPL D-33225, Prliminary, December 7 2005.
7. Phoenix TEGA Archive Volume Software Interface Specification, TBW.
8. CODMAC "Issues and Recommendations Associated with Distributed Computation and Data Management Systems for the Space Sciences", Committee on Data Management and Computation Space Science Board, National Research Council, National Academy Press, Washington, D.D., 1986
This SIS document and the products it describes could be affected by changes to PDS standards, Phoenix archive plans, the agreement between the TEGA Team and the PDS Geosciences Node, and the agreements among the Phoenix Science Operations Center, Phoenix instrument teams, and the PDS, as described in Applicable Documents 1, 2, 5, and 6. Changes to the design of the EDR products would require this SIS to be updated, and might also require updates to Applicable Document 7.
The TEGA instrument, one of seven instruments aboard the 2007 Phoenix Mars Lander, is a thermal and evolved-gas analyzer. TEGA is designed to analyze ~50 mg of fine grained soil or rock fragments that are loaded into ovens via a funnel. It consists of four basic components: a soil delivery system, an oven/calorimeter, a gas storage and handling system, and an evolved-gas analyzer (EGA).
TEGA will analyze eight soil/rock samples. The samples are acquired from the Martian surface by the Phoenix Robotic Arm. The arm scoops the soil sample up and deposits it in the TEGA soil delivery system. The TEGA soil delivery system is made up of a door release mechanism, a screen, a vibrating solenoid, a tri-bladed soil impeller, and the trough/funnel which delivers soil to the male oven half. A 1 mm grid screen acts to filter out particles too large for the oven. The vibrations of the solenoid are imparted to the entire thermal analyzer (TA) chassis to sift soil through the screen, as well as assist gravity in the movement of the soil down the trough to the funnel area of the TA, which fills the male oven half. A detector and LED pair is located across the collar of the funnel just above the male oven half. The LED/detector pair (LEDEDR) is used to indicate when the oven is filled.
TEGA is built with eight, single-use thermal analyzer (TA) cells, each of which has its own oven and sample receiving funnel. The TEGA ovens are very small. The inside dimensions are about 2.4 mm diameter and 8 mm long. The male half, which receives the sample material via a funnel, is inserted into the female half, which contains heater and temperature sensors. The TA cells are used to collect calorimetric data, i.e. temperatures and heat flows associated with thermal transitions in a material, on the sample. These data are collected to characterize the thermodynamic and chemical properties of the sample material. Calorimetric data (SCEDR) is obtained by carefully measuring the power applied to the oven to achieve a desired temperature during a programmed temperature ramp.
During the programmed temperature ramp a stream of N2 gas is run over the sample as it is heated from ambient temperatures to about 1000°C. The gas supply serves two purposes; one is to provide a carrier gas that moves the gases evolved from the sample material in the oven to the inlet of the EGA, and the other is to provide an on-surface known composition calibration gas. The gas storage and handling system consists of two tanks, valves to control and distribute the gasses to the eight TA modules and the EGA, and the associated plumbing. Various engineering readings associated with the gas will be recorded in the engineering data products (ENGEDR).
As a sample is heated, various gases are evolved depending on the nature of the sample. The evolved gas is passed through a manifold to the EGA. The EGA is a magnetic-sector mass spectrometer, which can determine both the quantity of the evolved gas and its isotopic composition (EGAEDR, EGHEDR). The detection limit of the EGA is 10 parts per billion. The EGA is synchronized to the temperature of the oven, so the composition of the gases can be correlated to their temperature of evolution. In Mass Hopping mode the EGA only scans certain selected masses. After the top of one mass peak is sampled, the instrument hops to another mass, skipping over insignificant peaks and the empty space between peaks.
TEGA is controlled by flight software that runs on the dedicated TEGA microprocessor. The flight software issues commands to the instrument, and collects housekeeping and science data (SCEDR, EGAEDR, EGHEDR, ENGEDR, MSGEDR, LEDEDR). The TEGA flight software reports TEGA specific information to the Lander command and data handling system. TEGA information collected by the Lander is then returned to Earth via the Deep Space Network.
Table 4‑1 summarizes TEGA standard data products.
Table 4‑1TEGA Standard Data Products
|
Product Type |
NASA Level |
Description |
PDS Data Set ID |
|
ENGEDR |
0 |
Engineering data from instrument sensors as time series (engineering values from EGA and TA) |
PHX-M-TEGA-2-ENGEDR-V1.0 |
|
SCEDR |
0 |
SC oven heating time series of raw values of oven and shield power, current, voltage and pulse |
PHX-M-TEGA-2-SCEDR-V1.0 |
|
EGAEDR |
0 |
EGA detector currents (time series of counts), selected scanned peaks |
PHX-M-TEGA-2-EGAEDR-V1.0 |
|
EGHEDR |
0 |
EGA Mass hopping counts (time series of counts) |
PHX-M-TEGA-2-EGHEDR - V1.0 |
|
LEDEDR |
0 |
Oven fill data (time series of raw and integrated LED readings) |
PHX-M-TEGA-2-LEDEDR-V1.0 |
|
MSGEDR |
0 |
Instrument message log |
PHX-M-TEGA-2-MSGEDR-V1.0 |
All EDR products are time-series data stored as binary tables described by detached PDS labels, with one table perActivity per Martian Sol. Details of the EDR data products are specified by product in Section 5.
This section provides general information about the processing of TEGA data products. Details specific to each data product are found in Section 5.
All TEGA EDR products are considered raw data, the NASA Level 0 (CODMAC Level 2) data processing level as defined in Appendix 7.0.
TEGA data products will be generated by the TEGA Team led by Co-Investigator Boynton at the Lunar and Planetary Laboratory,University of Arizona. Once a TEGA measurement is collected, it is stored on the Lander and held for periodic download. The stored telemetry data are downloaded periodically from the Lander for relay to the Deep Space Network (DSN). Data received from the DSN are inserted into the Jet Propulsion Laboratory's (JPL) Telemetry Data System (TDS). The University of Arizona (UA) queries the TDS for the most recent telemetry dataset. The dataset is output to a spooler that passes data to the UA. Raw telemetry data are received by the UA, and a number of automated computer processes are run to ingest the data into a database, and to transform the data into scientifically useful data products. The following sections describe this process in more detail.
TEGA_tl is the process by which telemetry data down-linked from the Phoenix Lander is transferred from the JPL TDS to the UA and prepared for ingestion into the UA TEGA database. Data packets are wrapped with specifically formatted headers at each phase of data transfer. The TEGA _tl program is designed to remove any or all of the header information and transform data packets to a useable form. TEGA _tl receives input data from any of a number of input sources (e.g. raw telemetry), strips out the TEGA specific data, and outputs that data in the requested format. In the case of telemetry data, a process on the JPL Spacecraft Operations Processing Computer (SOPC) called stot retrieves selected Standard Format Data Unit (SFDU) packets from the TDS via a query server, and sends the retrieved SFDU packets to a socket. A connection is made between the socket and TEGA _tl, and packet data is passed to TEGA _tl.
The stream of SFDU data packets is read in from the socket. The SFDU packet consists of a primary label, an aggregate header (Compressed Header Data Object, CHDO), up to 4 headers (Primary [required], secondary, tertiary, quaternary), and an optional data CHDO. The primary label and headers are stripped from the packet and are written to a file "SFDU.hdr." The remaining information is a Consultative Committee for Spacecraft Data Systems (CCSDS) packet, consisting of header information and data. The CCSDS headers are removed and written to a file "CCSDS.hdr." The remaining data is then in the form of a TEGA packet, and includes the data as output by the TEGA instrument suite. The TEGA data packets consist of a telemetry header structure, a data type specific data structure, and an appended checksum. The last step in the process is to convert the TEGA data packets to BCE (Bench Checkout Equipment) type packets. BCE type packets are a suite of data type specific packet formats with a common header structure that were developed for data transfer and handling during pre-flight tests. The packet definitions were found to work well, and have been modified only slightly during flight. BCE packets are formed by stripping the telemetry header from the TEGA packet and replacing it with the BCE common header structure followed by the data type specific data structure. Any needed regrouping or decompression of data occurs in the translation from TEGA to BCE data format.
Figure 4.1 TEGA_tl data flow diagram.
Data with an invalid telemetry header is flagged as "invalid header." If the checksum is not correct, then the packet is flagged as "bad checksum." The BCE formatted data are sent either to a data spooler (similar to a print spooler) to wait for database ingestion or to be written to files. If BCE output is written to files, it is placed in a Central Electronics Box (CEB) Telemetry structured directory which can then be used for data validation. The CEB telemetry data structure is a top level directory with standard sub-directories categorized by data type.
TEGA _tl can also be used to translate data from one packet type to another (Figure 4.1.) The input data stream can consist of SFDU packets, CCSDS packets or TEGA data packets. The packets are read, parsed, and translated to an output packet format. Output types can be SFDU, CCSDS, TEGA data or BCE formatted packets. The output packets can then be sent to a socket and/or written to a file. The only restrictions on data type transformation are that BCE packets can not be used as TEGA _tl input, and the data types can not be "up converted", for example CCSDS packets can not be transformed into SFDU packets.
The ingest process is the mechanism by which data is ingested into the UA TEGA database. The input data used by ingest are the BCE packet type output from the TEGA_tl program. Ingest receives data from the spooler and inserts it into the appropriate database tables.
Ingest initialization sets up the necessary connections to the SPICE kernel information, the database, and the input data. The SPICE kernel files are opened and loaded, and a connection to the database is established. Once the appropriate connections are made, the data ingestion begins.
Figure 4.2 TEGA Database Ingest data flow diagram
The Ingest function, which waits for the client on the socket, calls the input_open procedure. Input_open initializes the socket on the designated port. Once the socket is open, the proc_pkts function processes each packet of data through the input_next procedure. Input_next reads the socket header to get the total number of bytes in the packet, and then reads the common header to get the sequence bytes. The rest of the packet is then read.
The data type, read from the common header, is returned, determining the next step in the processing. One of eleven different procedures is run to insert packet data into the database (Figure 4.2). The insertion procedure is based on the data type being processed. If the data type returned is less than or equal to 0 an error message is returned stating that the packet was not inserted.
There are approximately ninety-five identically formatted engineering data tables (see Table 4‑2) in the UA database. The ingest process inserts the raw engineering data and TEGA time (tega_time) into each engineering table based on the engineering parameter name. The raw engineering values as received from the spacecraft are in a digital number (DN) format. The DN values are reported in the ENGEDR data product.
Table 4‑2TEGA Engineering Parameters
|
Engineering Parameter Name |
Description |
|
TA_MANIFOLD_PRES |
Manifold Pressure |
|
TA_PLUS_5_VREF |
+5V REF |
|
TA_OUTLET_PRES |
Outlet Pressure |
|
TA_MANIFOLD_TEMP |
TA Manifold Temperature |
|
TA_EGA_PLUMB_TEMP |
MS Plumbing Temperature |
|
TA_EGA_BAKEOUT_TEMP |
Bakeout temperature |
|
TA_PLUMBING_1_TEMP |
Plumbing 1 Temperature |
|
TA_PLUMBING_2_TEMP |
Plumbing 2 Temperature |
|
TA_EGA_MAN_TEMP |
MS Manifold Temperature |
|
TA_CAL_TANK_TEMP |
Cal Tank Temperature |
|
TA_CPU_TEMP |
CPU Temperature |
|
TA_PWR_SPLY_1_TEMP |
Power Supply 1 Temperature |
|
TA_PWR_SPLY_2_TEMP |
Power Supply 2 Temperature |
|
TA_PWR_CNTL_1_TEMP |
Power Control 1 Temperature |
|
TA_PWR_CNTL_2_TEMP |
Power Control 2 Temperature |
|
TA_A2D_TEMP |
ADC Temperature |
|
TA_COVER_1_TEMP |
cover 1 temperature |
|
TA_IN_FNL_1_LO_TEMP |
Funnel 1 Temperature |
|
TA_PRES_SENSE_FD_BK |
Pres Sense Exc. Feedback |
|
TA_IN_FNL_2_LO_TEMP |
Funnel 2 Temperature |
|
TA_OVEN_TEMP |
Oven Temperature |
|
TA_SHLD_TEMP |
Shield Temperature |
|
TA_EGA_ELECT_BOX_TEMP |
TEB Temperature |
|
TA_T_HEATER_TEMP |
"T" Heater Temperature |
|
TA_TRANS_TUBE_TEMP |
Transfer Tube Temperature |
|
TA_EGA_GEC_TEMP |
GEC Temperature |
|
TA_BUS_A_VOLT |
Bus A Voltage |
|
TA_AGD_0_1 |
AGD_0_3 ground |
|
TA_AGD_3_1 |
AGD_3_1 ground |
|
TA_CPU_PLUS_5_VOLT |
CPU Voltage |
|
TA_ANLG_PLUS_12_VOLT |
Analog +12V Voltage |
|
TA_ANLG_MINUS_12_VOLT |
Analog -12V Voltage |
|
TA_OVEN_PLUS_15_VOLT |
Oven Voltage |
|
TA_SHIELD_PLUS_30_VOLT |
Shield Voltage |
|
TA_BUS_A_CUR |
Bus A Current |
|
TA_BUS_B_CUR |
Bus B Current |
|
TA_EGA_CUR |
EGA Current |
|
TA_CPU_PLUS_5_CUR |
CPU Current |
|
TA_ANLG_PLUS_12_CUR |
Analog +12V Current |
|
TA_ANLG_MINUS_12_CUR |
Analog -12V Current |
|
TA_OVEN_PLUS_15_CUR |
Oven Current |
|
TA_SHIELD_PLUS_30_CUR |
Shield Current |
|
TA_FULL_DETECT |
Full Detect Integrated |
|
TA_FULL_DETECT_RAW |
Full Detect Raw |
|
TA_OVEN_ERR |
Oven Error |
|
TA_SHLD_ERR |
Shield Error |
|
TA_CAL_TANK_COLD_TEMP |
Cal Tank Cold Temperature |
|
TA_COVER_2_TEMP |
cover 2 Temperature |
|
MEM_OVEN_INT_LO |
Oven integrator value low bytes |
|
MEM_OVEN_INT_HI |
Oven integrator value high bytes |
|
MEM_SHLD_INT_LO |
Shield integrator value low bytes |
|
MEM_SHLD_INT_HI |
Shield integrator value high bytes |
|
MEM_OVEN_VOLT |
Oven voltage |
|
MEM_OVEN_CUR |
Oven current |
|
MEM_SHLD_VOLT |
Shield voltage |
|
MEM_SHLD_CUR |
Shield current |
|
MEM_MANIFOLD_PRES |
Manifold pressure |
|
MEM_OVEN_ERR |
Oven error |
|
MEM_SHLD_ERR |
Shield error |
|
MEM_T_WIDTH |
T pulse width |
|
COVER1_DONE |
Cover1 Limit Switch |
|
COVER2_DONE |
Cover2 Limit Switch |
|
MEM_OVEN_WIDTH |
Oven pulse width |
|
MEM_SHLD_WIDTH |
Shield pulse width |
|
EGA_STATUS_BITS |
Status bits value |
|
EGA_TRAP_CUR |
Trap current monitor |
|
EGA_EMISSION_CUR |
Emission current monitor |
|
EGA_FILAMENT_1 |
Filament 1 in use |
|
EGA_FILAMENT_2 |
Filament 2 in use |
|
EGA_PLUS_5_VOLT |
+5 volt monitor |
|
EGA_PLUS_12_VOLT |
+12 volt monitor |
|
EGA_MINUS_12_VOLT |
-12 volt monitor |
|
EGA_FILAMENT_CUR_1 |
Filament 1 current monitor |
|
EGA_FILAMENT_CUR_2 |
Filament 2 current monitor |
|
EGA_MULTIPLIER_VOLT |
Multiplier voltage monitor |
|
EGA_ION_PUMP_VOLT |
Ion Pump voltage monitor |
|
EGA_ION_PUMP_CUR |
Ion Pump Current monitor |
|
EGA_SWEEP_VOLT |
Sweep voltage monitor |
|
EGA_GEC_CUR |
GEC current monitor |
|
EGA_MAGNET_TEMP_1 |
Magnet 1 temperature |
|
EGA_MAGNET_TEMP_2 |
Magnet 2 temperature |
|
EGA_PROC_TEMP |
CPU temperature |
|
EGA_AVG_CALLS |
Average # of calls to Task Queue |
|
EGA_MIN_CALLS |
Minimum # of calls to Task Queue |
|
EGA_SPARE_3 |
Spare |
|
EGA_SPARE_4 |
Spare |
|
ANALOG_CAL_TANK |
Caltank heater |
|
ANALOG_TA_MANIFOLD |
TA manifold heater |
|
ANALOG_TA_PLUMB_1 |
TA plumbing 1 heater |
|
ANALOG_TA_PLUMB_2 |
TA plumbing 2 heater |
|
ANALOG_ EGA_MANIFOLD |
EGA manifold heater |
|
ANALOG_EGA_SPARE |
EGA spare heater |
|
ANALOG_EGA_BOX |
EGA electronics box heater |
|
ANALOG_EGA_BAKE |
EGA bake out heater |
|
ANALOG_HI_PWR_SPARE |
Spare |
|
ANALOG_TRANS_TUBE |
Transfer Tube heater |
|
ANALOG_T |
T heater |
Once all telemetry values have been inserted into the TEGA database at UA, EDR data products can be generated. After EDR data product generation, advanced processing can be done that will result in the Reduced Data Record (RDR) data products.
The TEGA EDR are then generated from the TEGA data that has been stored in the TEGA database, as discussed in Section 4.2.2. Table 4.3 lists the time span covered by each data product, the data product generation interval, the expected size of each of the EDR data products, and the total expected data volume for each product.
Table 4‑3TEGA EDR Data Volume
|
Product Type |
Time span covered |
Generation Interval |
Expected Size of Product (bytes) |
Total Data Volume (bytes) |
|
ENGEDR |
1 Activity on 1 Sol |
90 sols* |
2,600,000 |
117,000,000 |
|
SCEDR |
1 Activity on 1 Sol |
90 sols |
560,000 |
25,200,000 |
|
EGAEDR |
1 Activity on 1 Sol |
90 sols |
46,000 |
2,070,000 |
|
EGHEDR |
1 Activity on 1 Sol |
90 sols |
1,600,000 |
72,000,000 |
|
LEDEDR |
1 Activity on 1 Sol |
90 sols |
16,000 |
720,000 |
|
MSGEDR |
1 Activity on 1 Sol |
90 sols |
270,000 |
12,150,000 |
* TEGA will only be running for approximately 45 sols
The TEGA EDR products are assembled into archive volumes at the UA and then delivered to the Phoenix Science Operations Center (SOC) where they are made available to other Phoenix science teams. The SOC will then deliver the TEGA archive volumes to the PDS Geosciences Node for release to the public. This data flow is governed by Applicable Document 6.
This section specifies various standards that apply to TEGA data products.
The file naming scheme defined for the Phoenix Lander instrument products adheres to, and is compliant with the PDS Level II 27.3 filename standards. The file naming convention described here divides the filename into two parts (none consecutive). The first part is instrument-independent, or generic, containing a minimal set of fields, which apply to all instruments aboard the Phoenix Lander. The second part is reserved for instrument-specific fields.
Each product name must be uniquely identifiable throughout the mission by incorporating a combination of relevant fields such as Spacecraft Clock count (SCLK), instrument identifier, data source, observation identifier, product token, etc.
The generic portion of the file name as described here, is not sufficient for uniqueness. The information saved in the instrument-specific portion, in conjunction with the generic portion, must guarantee uniqueness.
The file naming rules are as follows:
I. Only letters A-Z, digits 0-9 and the underscore ("_") may be used.
II. All characters must be in upper case.
III. The full length of product name must be 31 characters, 27 for the filename followed by a "." and a three-character file extension.
IV. All fields and sub-fields must be filled or padded with "_" (ASCII underscore) as needed to maintain proper length. For number fields, zeros should be used instead.
V. The convention used for/by instrument must guarantee uniqueness throughout the whole mission.
.
A template for general filename is shown below, and the table that follows provides additional detail for individual fields.
Table 4‑4 File Naming Template
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
23 |
24 |
25 |
26 |
27 |
28 |
29 |
30 |
31 |
|
Instrument |
Source/Epic |
Sol |
Product Type |
Instrument Specific |
Producer |
Version |
. |
Extension |
||||||||||||||||||||||
The "Instrument Specific" portion is reserved for each instrument/team to use as needed, within the boundaries stated by the above rules.
Table 4‑5 Detailed description of product name components
|
Position |
Name |
Description/value |
|
1 |
Instrument |
S SSI R RAC T TEGA A RA O MECA-OM P MECA-TECP F MECA-AFM W MECA-WCE X MECA-Misc M MET-P&T L MET-LIDAR D MARDI E ASE |
|
2 |
Source/Epic |
Spacecraft S Surface, flight model T Test-bed C Cruise, flight model |
|
3-5 |
SOL |
Solar days since first full day on Mars. Landing day is Sol zero. If Source/Epic is T, day of year should be used (ERT or SCET). For cruise phase, always set to "_C_". |
|
6-8 |
Product Type |
These 3-char identifiers are differentiated as either EDR (Level 0) or RDR (Level 1+) products. If the identifier begins with an "E", then the product is a type of EDR. Otherwise, it is a type of RDR.
See applicable instrument SIS documents for detailed descriptions of all valid product types for each instrument. |
|
9-25 |
Reserved |
Reserved, and required, for instrument-specific fields. See applicable instrument EDR/RDR SIS documents for details. Unused positions are filled with "_" (ASCII underscore) |
|
26 |
Producer (Reserved) |
Producer's id, although part of the reserved portion for instrument-specific field, this field to be used to identify the generating entity of the product. M MIPL T TEGA
|
|
27 |
Version |
Version number, 0-9,A-Z (36 total) |
|
28 |
Period |
Always set to "." (ASCII period) |
|
29-31 |
File Extension |
PDS file extension, instrument specific. IMG Imaging/Camera data DAT Non-imaging instrument data QUB Multi-layer, cube products TAB Table/tabular data
See table 10-1 in the PDS Standards Ref. for complete list of acceptable extensions |
Table 4‑6 TEGA-specific EDR file names
|
Character Position |
1-8 |
9-27 |
28-31 |
|
ENGEDR Product |
TSnnnEDR |
_aa_bbb_yyyymmdd_cv |
.DAT |
|
ENGEDR Examples |
TS020EDR |
_TA_MAN_20080501_U1 |
.DAT |
|
All other EDR products |
TSnnnEDR |
_aaa_yyyy_mm_dd__cv |
.DAT |
|
SCEDR Example |
TS020EDR |
__SC_2008_05_01__U1 |
.DAT |
|
EGAEDR Example |
TS020EDR |
_EGA_2008_05_01__U1 |
.DAT |
|
EGHEDR Example |
TS020EDR |
_EGH_2008_05_01__U1 |
.DAT |
|
LEDEDR Example |
TS020EDR |
_LED_2008_05_01__U1 |
.DAT |
|
MSGEDR Example |
TS020EDR |
_MSG_2008_05_01__U1 |
.DAT |
TEGA EDR data products comply with Planetary Data System standards as specified in the PDS Standards Reference (Applicable Document 1). All filenames, by definition, will be PDS compliant. Additional identification information will be contained in the PDS label as described in Appendix 7 starting on page 25.
The following time standards and conventions are used throughout this document, as well as the Phoenix project, for planning activities and identification of events:
SCET Spacecraft event time: The time when an even occurred on-board, in UTC.
SCLK Spacecraft Clock: An on-board 64-bit counter, in units of nano-seconds, which increments once every 100 milliseconds, with origin, set to zero, at midnight on
1-Jan-1980.
ERT Earth Received Time (UTC): The time when the first bit of the packet containing the current data was received at the Deep Space (DSN) station.
Local Solar Time: LST is the local solar time expressed by the number of local solar days (SOLs) from a landing date and using a "24-hour" clock readout within the current local solar day (HR:MN:SC); LST is a true local solar time and computed using positions of the Sun and the landing site from SPICE kernels specified in CHRONOS setup file; if a landing date is unknown to the program it cannot convert input LST to any other time system and can compute LST only without SOL number for the output; LST examples: SOL 12 12:00:01 SOL 132 01:22:32.498 SOL 2 9.
The following coordinate systems are used within the project to refer to the position of the Lander and its instruments.
|
Coordinate System |
Origin |
Orientatioin |
|
Local Level |
Same as payload frame, and it moves with the Lander |
+X North +Z down along gravity vector +Y East |
|
Payload Frame |
At the shoulder of the Robotic Arm. Attached and moves with the Lander |
+X along Lander -X ( point out into the work space) +Z down along Lander (vertical axis) +Y along Lander -Y
|
|
Site Frame |
Same as payload frame when first defined and never moves relative to Mars. Possible to define multiple site frames in case the Lander moves/slips. |
Same as local level |
Phoenix imaging product conventions are as follows.
TEGA products will be stored as ASCII text files having variable length records, with each record terminated by ASCII carriage-return and line-feed characters. Each EDR file will be described by a detached PDS label in another file with the same .LBL. EDR products are defined as PDS spreadsheet objects. See Table 7‑2 Columns in TEGA Data Products on page 26.
Each TEGA data product label includes the Phoenix-specific keyword OPS_TOKEN.
The OPS_TOKEN is a code associated with a Phoenix data product that provides information about the command sequence that caused the product to be acquired. The value is a 32-bit unsigned hexadecimal integer expressed in a PDS label as 16#AAAAPCCC#, where:
The combination of OPS_TOKEN and sol number should uniquely identify a Phoenix data product.
For TEGA products, the payload ID field (bits 17-20) is defined as 0.
Validation of the TEGA product during production will be done according to specifications in the Phoenix Archive Plan and the TEGA - Geosciences Node ICD. The TEGA Team will validate the science content of the data products, and the Geosciences Node will validate the products for compliance with PDS standards and for conformance with the design specified in this SIS.
The TEGA data product has detached PDS labels stored as ASCII text. A PDS label is object-oriented and describes the objects in the data file. The PDS label contains the keywords for product identification and for data object definitions. The label also contains descriptive information needed to interpret or process the data objects in the file.
PDS labels are written in Object Description Language (ODL) [4]. PDS label statements have the form of "keyword = value". Each label statement is terminated with a carriage return character (ASCII 13) and a line feed character (ASCII 10) sequence to allow the label to be read by many operating systems. Pointer statements with the following format are used to indicate the location of data objects:
^object = location
where the carat character (^, also called a pointer) is followed by the name of the specific data object. The location is the name of the file that contains the data object.
The ENGEDR (TEGA Engineering Data) are raw engineering data packets collected from 92 engineering sensors aboard the TEGA instrument. The data product is structured as 92, 3-column, time ordered data files. Each data file corresponds to a single engineering parameter. (See, Table 4‑2 TEGA Engineering Parameters, on page 7 for the list of engineering parameters.)
This product is organized as 92 binary data files containing raw engineering data collected over a single activity during a measurement days, with a detached ASCII text PDS label file (See Appendix 7.2, Example ENGEDR PDS Label, on page 28) for each binary data file. Each engineering data file will be labeled in a format of a 27 character string with a .DAT file extension. The first eight characters indicate instrument and product level. The second eight characters indicate engineering parameters. The third eight characters indicate the date of collection. The last three characters indicate the location where data were produced. These 92 data files will be grouped together by activity on a measurement day. The data folders will be labeled by activity and grouped by Sol.
The data format for the ENGEDR is a 3 column binary table that varies in width from 2 to 8 bytes. Column structure and start byte are described in Appendix 7.2, Example ENGEDR PDS Label, on page 28. The number of rows in a data table will depend on the number of collection intervals during the measurement period. We would expect approximately 1000 data records per file, but there may be some variations due to short data gaps. The following is the contents of the TEGA_ENG.FMT file.
OBJECT = COLUMN
COLUMN_NUMBER = 1
NAME = SC_TIME
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 8
START_BYTE = 1
DESCRIPTION = "Spacecraft time when this engineering reading was taken, in ticks (256 per second)."
END_OBJECT = COLUMN
OBJECT = COLUMN
COLUMN_NUMBER = 2
NAME = TEGA_TIME
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 4
START_BYTE = 9
UNIT = MILLISECOND
DESCRIPTION = "The TEGA time, in milliseconds when the reading was taken."
END_OBJECT = COLUMN
OBJECT = COLUMN
COLUMN_NUMBER = 3
NAME = RAW_VAL
DATA_TYPE = INTEGER
BYTES = 2
START_BYTE = 13
DESCRIPTION = "The raw digital value of the reading as output from the analog-to-digital converter in the Software."
END_OBJECT = COLUMN
The SCEDR (TEGA Scanning Calorimeter Data Records) are scanning calorimetry data packets from the TA that contain raw values for oven and shield power, current, voltage and pulse. The data product is structured as a time series, 6-column data table. See Appendix 7.3, Example SCEDR PDS Label, on page 88 for the table structure.
This product is organized as a binary data file containing SC data collected over a single activity during a measurement day, with a detached ASCII text PDS label file (see Appendix 7.3, Example SCEDR PDS Label, on page 88) for each binary data file. The data folders will be labeled by activity and grouped by Sol.
The data format for the SCEDR is a 6 column binary table that varies in width from 2 to 66 bytes. Column structure and start byte are described in Appendix. The number of rows in a data table will depend on the number of collection intervals during the measurement period. We would expect approximately 50 data records per file, but there may be some variations due to short data gaps. The following is the contents of the TEGA_SC.FMT file.
OBJECT = COLUMN
COLUMN_NUMBER = 1
NAME = SC_TIME
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 8
START_BYTE = 1
DESCRIPTION = "
Spacecraft time when these reading was taken, in ticks
(256 per second).
"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEGA_START_TIME
COLUMN_NUMBER = 2
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 9
DESCRIPTION = "TEGA time at the beginning of the collection,
in milliseconds"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEGA_END_TIME
COLUMN_NUMBER = 3
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 13
DESCRIPTION = "TEGA time at the end of the collection, in
milliseconds"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SUM_COUNT
COLUMN_NUMBER = 4
BYTES = 2
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 17
DESCRIPTION = "Number of 3 msec readings that are summed in each
record"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = NUM_RECORDS
COLUMN_NUMBER = 5
BYTES = 2
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 19
DESCRIPTION = "The number of SC records to follow"
END_OBJECT = COLUMN
OBJECT = CONTAINER
NAME = SC_RECORDS
START_BYTE = 21
BYTES = 66
REPETITIONS = 60
^STRUCTURE = "SC_REC.FMT"
DESCRIPTION = "."
END_OBJECT = CONTAINER
The EGAEDR (TEGA Evolved Gas Analyzer Data Record) are raw EGA detector current data packets. The data product is structured as a time series, 6-column data table. See Appendix 7.4, Example EGAEDR PDS Label, on page 89 for the table structure.
This product is organized as a binary data file containing EGA data collected over a single activity during a measurement day, with a detached ASCII text PDS label file (see Appendix 7.4, Example EGAEDR PDS Label, on page 89) for each binary data file. The data folders will be labeled by activity and grouped by sol.
The data format for the EGAEDR is an 8-column binary table that varies in width from 8 to 24 bytes. Column structure and start byte are described in Appendix 7.4. The number of rows in a data table will depend on the number of collection intervals during the measurement period. We would expect approximately 50 data records per file, but there may be some variations due to short data gaps. The following is the contents of the TEGA_EGA.FMT file.
OBJECT = COLUMN
COLUMN_NUMBER = 1
NAME = SC_TIME
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 8
START_BYTE = 1
DESCRIPTION = "Spacecraft time when this engineering reading
was taken, in ticks (256 per second)."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEGA_START_TIME
COLUMN_NUMBER = 2
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 9
DESCRIPTION = "TEGA time at the beginning of the collection in
milliseconds"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEGA_END_TIME
COLUMN_NUMBER = 3
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 13
DESCRIPTION = "TEGA time at the end of the collection in
milliseconds"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = EGA_TIME
COLUMN_NUMBER = 4
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 17
DESCRIPTION = "EGA time of the collection in seconds"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SCAN_TYPE
COLUMN_NUMBER = 5
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 21
DESCRIPTION = "Type of scan that is being sent, 1 sweep,
4 calibration"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = PACKET_NUM
COLUMN_NUMBER = 6
BYTES = 2
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 22
DESCRIPTION = "number of the packet in the set, MSB set if last"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = REC_COUNTS
COLUMN_NUMBER = 7
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 24
DESCRIPTION = "Number of valid records in the record container"
END_OBJECT = COLUMN
OBJECT = CONTAINER
NAME = EGA_RECORDS
START_BYTE = 25
BYTES = 22
REPETITIONS = 54
^STRUCTURE = "EGA_REC.FMT"
DESCRIPTION = "."
END_OBJECT = CONTAINER
The EGHEDR (TEGA EGA Mass Hopping Data Record) are raw EGA mass hopping data packets (selected mass peaks). The data product is structured as a time series, 8-column data table. See Appendix 7.5, Example EGHEDR PDS Label, on page 90 for the table structure.
This product is organized as a binary data file containing EGA mass hopping data collected over a single activity during a measurement day, with a detached ASCII text PDS label file (see page 90) for each binary data file. The data folders will be labeled by activity and grouped by sol.
The data format for the EGHEDR is a 6-column binary table that varies in width from 1 to 8 bytes. Column structure and start byte are described in Appendix 7.5, Example EGHEDR PDS Label, on page 90. The number of rows in a data table will depend on the number of collection intervals during the measurement period. We would expect approximately 50 data records per file, but there may be some variations due to short data gaps. The following is the contents of the TEGA_EGH.FMT file.
OBJECT = COLUMN
COLUMN_NUMBER = 1
NAME = SC_TIME
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 8
START_BYTE = 1
DESCRIPTION = "
Spacecraft time when this engineering reading was taken, in ticks
(256 per second).
"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEGA_START_TIME
COLUMN_NUMBER = 2
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 9
DESCRIPTION = "TEGA time at the beginning of the collection, in
milliseconds"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEGA_END_TIME
COLUMN_NUMBER = 3
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 13
DESCRIPTION = "TEGA time at the end of the collection, in
milliseconds"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = EGA_TIME
COLUMN_NUMBER = 4
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 17
DESCRIPTION = "EGA time of the collection, in seconds"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SCAN_TYPE
COLUMN_NUMBER = 5
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 21
DESCRIPTION = "bits 0 through 2 indicate type of scan that
is being sent, 2 mass mode, 3 super mode. If super mode bits
3 through 7 indicate the super mode number"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = PACKET_NUM
COLUMN_NUMBER = 6
BYTES = 2
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 22
DESCRIPTION = "number of the packet in the set, MSB set if last
packet"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = REC_COUNTS
COLUMN_NUMBER = 7
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 24
DESCRIPTION = "Number of valid records in the record container"
END_OBJECT = COLUMN
OBJECT = CONTAINER
NAME = EGH_RECORDS
START_BYTE = 25
BYTES = 11
REPETITIONS = 109
^STRUCTURE = "EGH_REC.FMT"
DESCRIPTION = "."
END_OBJECT = CONTAINER
The LEDEDR (TEGA LED Data Records) are raw and integrated oven fill data packets. The data product is structured as a time series, 6-column data table. See Appendix 7.6, Example LEDEDR PDS Label, on page 91 for the table structure.
This product is organized as a binary data file containing LED data collected over a single activity during a measurement day, with a detached ASCII text PDS label file (see Appendix 7.6, Example LEDEDR PDS Label, on page 91) for each binary data file. The data folders will be labeled by activity and grouped by sol.
The data format for the LEDEDR is a 6-column binary table that varies in width from 1 to 8 bytes. Column structure and start byte are described in Appendix 7.6, Example LEDEDR PDS Label, on page 91. The number of rows in a data table will depend on the number of collection intervals during the measurement period. We would expect approximately 50 data records per file, but there may be some variations due to short data gaps. The following is the contents of the TEGA_LED.FMT file.
OBJECT = COLUMN
COLUMN_NUMBER = 1
NAME = SC_TIME
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 8
START_BYTE = 1
DESCRIPTION = "
Spacecraft time when this engineering reading was taken, in ticks
(256 per second)."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEGA_START_TIME
COLUMN_NUMBER = 2
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 9
DESCRIPTION = "TEGA time at the beginning of the collection, in
milliseconds"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEGA_END_TIME
COLUMN_NUMBER = 3
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 13
DESCRIPTION = "TEGA time at the end of the collection, in
milliseconds"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TYPE
COLUMN_NUMBER = 4
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 17
DESCRIPTION = "type of packet, fast = 0, or slow = 1"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = COUNT
COLUMN_NUMBER = 5
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 18
DESCRIPTION = "Number of records in the container"
END_OBJECT = COLUMN
OBJECT = CONTAINER
NAME = LED_RECORDS
START_BYTE = 19
BYTES = 4
REPETITIONS = 1000
^STRUCTURE = "LED_REC.FMT"
DESCRIPTION = "."
END_OBJECT = CONTAINER
The MSGEDR (TEGA Message Data Records) are raw instrument message data packets. The data product is structured as a time series, 4-column data table. See Appendix 7.7, Example MSGEDR PDS Label, on page 93 for the table structure.
This product is organized as a binary data file containing message data collected over a single activity during a measurement day, with a detached ASCII text PDS label file (see Appendix 7.7, Example MSGEDR PDS Label, on page 93) for each binary data file. The data folders will be labeled by activity and grouped by sol.
The data format for the MSGEDR is a 4-column binary table that varies in width from 1 to 128 bytes. Column structure and start byte are described in Appendix 7.7, Example MSGEDR PDS Label, on page 93. The number of rows in a data table will depend on the number of collection intervals during the measurement period. We would expect approximately 5000 data records per file, but there may be some variations due to short data gaps. The following is the contents of the TEGA_MSG.FMT file.
OBJECT = COLUMN
COLUMN_NUMBER = 1
NAME = SC_TIME
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 8
START_BYTE = 1
DESCRIPTION = "
The spacecraft time this message was generated, in ticks (256 per
second).
"
END_OBJECT = COLUMN
OBJECT = COLUMN
COLUMN_NUMBER = 2
NAME = MSG_ID
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 2
START_BYTE = 9
DESCRIPTION = "
Identifies type of message. See Label for details.
"
END_OBJECT = COLUMN
OBJECT = COLUMN
COLUMN_NUMBER = 3
NAME = ORIGIN
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 1
START_BYTE = 11
DESCRIPTION = "
Origin of execution (loader or flight software).
"
END_OBJECT = COLUMN
OBJECT = COLUMN
COLUMN_NUMBER = 4
NAME = MESSAGE_TEXT
DATA_TYPE = CHARACTER
BYTES = 128
START_BYTE = 12
DESCRIPTION = "
More verbose description of message.
"
END_OBJECT = COLUMN
There is no software being supplied with this product.
The only utility program being used with this product is NASAView which is described in the Applicable PDS Software Tools section below.
PDS-labeled images and tables can be viewed with the program NASAView, developed by the PDS and available for a variety of computer platforms from the PDS web site http://pds.nasa.gov/tools/software_download.cfm. There is no charge for NASAView.
There are no software distribution or update procedures associated with this product.
Table 7‑1 shows definitions of processing levels as defined by NASA and by CODMAC, the Committee on Data Management and Computation (Applicable Document 8.)
Table 7‑1Data Processing Levels
|
NASA |
CODMAC |
Description |
|
Packet data |
Raw - Level 1 |
Telemetry data stream as received at the ground station, with science and engineering data embedded. |
|
Level-0 |
Edited - Level 2 |
Instrument science data (e.g., raw voltages, counts) at full resolution, time ordered, with duplicates and transmission errors removed. |
|
Level 1A |
Calibrated - Level 3 |
Level 0 data that have been located in space and may have been transformed (e.g., calibrated, rearranged) in a reversible manner and packaged with needed ancillary and auxiliary data (e.g., radiances with the calibration equations applied). |
|
Level 1B |
Resampled - Level 4 |
Irreversibly transformed (e.g., resampled, remapped, calibrated) values of the instrument measurements (e.g., radiances, magnetic field strength). |
|
Level 1C |
Derived - Level 5 |
Level 1A or 1B data that have been resampled and mapped onto uniform space-time grids. The data are calibrated (i.e., radiometrically corrected) and may have additional corrections applied (e.g., terrain correction). |
|
Level 2 |
Derived - Level 5 |
Geophysical parameters, generally derived from Level 1 data, and located in space and time commensurate with instrument location, pointing, and sampling. |
|
Level 3 |
Derived - Level 5 |
Geophysical parameters mapped onto uniform space-time grids. |
|
|
Ancillary - Level 6 |
Data needed to generate calibrated or resampled data sets. |
All TEGA data products are stored as binary tables. Table 7‑2 lists the columns in TEGA EDR data products in alphabetical order. The format of each type of data product, including column positions, sizes, data types, units, and full descriptions, can be found in the format files (*.FMT) in the LABEL directory of the data archive.
Table 7‑2Columns in TEGA Data Products
|
Column Name |
Data Type |
Length in bytes |
Description |
Appears In |
COUNT |
MSB_UNSIGNED INTEGER |
1 byte |
Number of records in the container |
LEDEDR |
|
EGA_TIME |
MSB_UNSIGNED_INTEGER |
4 bytes |
EGA time of the collection |
EGAEDR, EGHEDR |
|
MSG_ID |
MSB_UNSIGNED_INTEGER |
9 bytes |
Identifies type of message. See Label for details. |
MSGEDR |
|
ORIGIN |
MSB_UNSIGNED_INTEGER |
1 byte |
Origin of execution (loader or flight software). |
MSGEDR |
|
PACKET_NUM |
MSB_UNSIGNED_INTEGER |
2 bytes |
Number of packets in the set, MSB set if last |
EGAEDR, EGHEDR |
|
REC_COUNTS |
MSB_UNSIGNED_INTEGER |
1 byte |
Number of valid records in the record container |
EGAEDR, EGHEDR |
|
SC _TIME |
MSB_UNSIGNED_INTEGER |
8 bytes |
Spacecraft time when reading was taken, in ticks (256 per second). |
ENEDR, MSGEDR, EGAEDR, EGHEDR, LEDEDR |
|
SCAN_TYPE |
MSB_UNSIGNED_INTEGER |
1 byte |
Type of scan that is being sent, 1 sweep, 4 calibration |
EGAEDR, EGHEDR |
|
SUM_COUNT |
MSB_UNSIGNED_INTEGER |
2 bytes |
Number of 3 msec readings that are summed in each record |
SCEDR |
|
TEGA_TIME |
INTEGER |
2 bytes |
The TEGA time when the reading was taken |
ENEDR |
|
TEGA_START_TIME |
MSB_UNSIGNED_INTEGER |
4 bytes |
Time at the start of the collection interval |
SCEDR, EGAEDR, LEDEDR, EGHEDR, MSGEDR |
|
TEGA_END_TIME |
MSB_UNSIGNED_INTEGER |
4 bytes |
Time at the end of the collection interval |
SCEDR, EGAEDR, LEDEDR, EGHEDR, MSGEDR |
|
TYPE |
MSB_UNSIGNED_INTEGER |
1 byte |
Type of packet, fast or slow |
LEDEDR |
PDS_VERSION_ID = PDS3
/* IDENTIFICATION DATA ELEMENTS */
DATA_SET_NAME = "PHX MARS THERMAL EVOLVED GAS
ANALYZER 1 EDR V1.0"
DATA_SET_ID = "PHX-M-TEGA-1-EDR-V1.0"
PRODUCT_VERSION_ID = "1.0"
RELEASE_ID = "0001"
OPS_TOKEN = 16#40406720#
/* DESCRIPTIVE DATA ELEMENTS */
INSTRUMENT_HOST_NAME = "2007 MARS PHOENIX"
INSTRUMENT_NAME = "THERMAL EVOLVED GAS ANALYZER"
SPACECRAFT_ID = PHX
TARGET_NAME = MARS
MISSION_PHASE_NAME = "PRIMARY MISSION"
START_TIME = 2008-05-01T14:14:32.890
STOP_TIME = 2008-05-01T20:09:44.149
SPACECRAFT_CLOCK_START_COUNT = 208023626065
SPACECRAFT_CLOCK_STOP_COUNT = 208035731925
PRODUCT_CREATION_TIME = 2008-09-15T10:54:47.894
/* DATA OBJECT DEFINITION */
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_MAN_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_MAN_20080501_U1.DAT"
PRODUCT_TYPE = "TA_MANIFOLD_PRES"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal analyzer manifold pressure,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_P5R_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_P5R_20080501_U1.DAT"
PRODUCT_TYPE = "TA_PLUS_5_VREF"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Plus 5 Voltage
Reference, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_OUT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_OUT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_OUTLET_PRES"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Outlet pressure,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_MAT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_MAT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_MANIFOLD_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Manifold
temperature,in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_EPT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_EPT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_EGA_PLUMB_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer Plumbing
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_EBT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_EBT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_EGA_BAKEOUT_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer bake out
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_P1T_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_P1T_20080501_U1.DAT"
PRODUCT_TYPE = "TA_PLUMBING_1_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Plumbing 1
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_P2T_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_P2T_20080501_U1.DAT"
PRODUCT_TYPE = "TA_PLUS_5_VREF"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Plumbing 2
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_EMT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_EMT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_EGA_MAN_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer manifold
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_CTT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_CTT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_CAL_TAMP_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Calibration Gas
Tank temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_CPT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_CPT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_CPU_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer CPU temperature,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_PS1_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_PS1_20080501_U1.DAT"
PRODUCT_TYPE = "TA_PWR_SPLY_1_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Power supply 1
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_PS2_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_PS2_20080501_U1.DAT"
PRODUCT_TYPE = "TA_PWR_SPLY_2_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Power supply 2
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_PC1_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_PC1_20080501_U1.DAT"
PRODUCT_TYPE = "TA_PWR_CNTL_1_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Control board temp
1, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_PC2_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_PC2_20080501_U1.DAT"
PRODUCT_TYPE = "TA_PWR_CNTL_2_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Power control
board temp 2, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_ADT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_ADT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_A2D_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Analog to digital
converter temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_C1T_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_C1T_20080501_U1.DAT"
PRODUCT_TYPE = "TA_COVER_1_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Cover 1
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_FL1_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_FL1_20080501_U1.DAT"
PRODUCT_TYPE = "TA_IN_FNL_1_LO_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer input funnel 1 low
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_PSC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_PSC_20080501_U1.DAT"
PRODUCT_TYPE = "TA_PRES_SENSE_FD_BK"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Pressure sensor,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_FL2_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_FL2_20080501_U1.DAT"
PRODUCT_TYPE = "TA_IN_FNL_2_LO_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer input funnel 2 low
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_OVT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_OVT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_OVEN_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Oven temperature,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_SHT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_SHT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_SHLD_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Shield
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_EGT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_EGT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_EGA_ELECT_BOX_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved gas analyzer electronics
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_THT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_THT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_T_HEATER_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer T heater
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_TTT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_TTT_20080501_U1.DAT"
PRODUCT_TYPE = "TA_TRANS_TUBE_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Transfer tube
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_GEC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_GEC_20080501_U1.DAT"
PRODUCT_TYPE = "TA_EGA_GEC_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Gas enrichment cell temperature,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_BAV_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_BAV_20080501_U1.DAT"
PRODUCT_TYPE = "TA_BUS_A_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Bus A voltage, in
DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_G03_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_G03_20080501_U1.DAT"
PRODUCT_TYPE = "TA_AGD_3_0"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Analog ground 0.3,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_G31_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_G31_20080501_U1.DAT"
PRODUCT_TYPE = "TA_AGD_3_1"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer analog ground 3.1,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_P5V_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_P5V_20080501_U1.DAT"
PRODUCT_TYPE = "TA_CPU_PLUS_5_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer CPU plus 5 volt,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_APV_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_APV_20080501_U1.DAT"
PRODUCT_TYPE = "TA_ANLG_PLUS_12_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer analog plus 12
voltage, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_AMV_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_AMV_20080501_U1.DAT"
PRODUCT_TYPE = "TA_ANLG_MINUS_12_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Oven temperature,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_OPV_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_OPV_20080501_U1.DAT"
PRODUCT_TYPE = "TA_OVNE_PLUS_15_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Oven plus 15
voltage, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_SPV_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_SPV_20080501_U1.DAT"
PRODUCT_TYPE = "TA_SHLD_PLUS_30_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer shield plus 30
voltage, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_BAC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_BAC_20080501_U1.DAT"
PRODUCT_TYPE = "TA_BUS_A_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Bus A current,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_BBC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_BBC_20080501_U1.DAT"
PRODUCT_TYPE = "TA_BUS_B_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Bus B current, in
DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_EGC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_EGC_20080501_U1.DAT"
PRODUCT_TYPE = "TA_EGA_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer current, in
DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_P5C_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_P5C_20080501_U1.DAT"
PRODUCT_TYPE = "TA_CPU_PLUS_5_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer CPU plus 5 current,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_APC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_APC_20080501_U1.DAT"
PRODUCT_TYPE = "TA_ANLG_PLUS_12_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer analog plus 12
current, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_AMC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_AMC_20080501_U1.DAT"
PRODUCT_TYPE = "TA_ANLG_MINUS_12_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer anolog minus 12
current, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_OPC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_OPC_20080501_U1.DAT"
PRODUCT_TYPE = "TA_OVEN_PLUS_15_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Oven plus 15
current, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_SPC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_SPC_20080501_U1.DAT"
PRODUCT_TYPE = "TA_SHLD_PLUS_30_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer shield plus 30
current, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_FDE_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_FDE_20080501_U1.DAT"
PRODUCT_TYPE = "TA_FULL_DETECT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Full detect
integrated diode sensor, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_FDR_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_FDR_20080501_U1.DAT"
PRODUCT_TYPE = "TA_FULL_DETECT_RAW"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer full detect raw
diode sensor reading, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_OER_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_OER_20080501_U1.DAT"
PRODUCT_TYPE = "TA_OVEN_ERR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Oven error, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_SER_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_SER_20080501_U1.DAT"
PRODUCT_TYPE = "TA_SHLD_ERR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Shield error, in
DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_CTC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_CTC_20080501_U1.DAT"
PRODUCT_TYPE = "TA_CAL_TANK_COLD_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Calibration gas
cold temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_C2T_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_C2T_20080501_U1.DAT"
PRODUCT_TYPE = "TA_COVER_2_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Cover 2
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_OIL_20080501_U1.DAT"
99
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_OIL_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_OVEN_INT_LO"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer oven integrator
low word, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_OIH_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_OIH_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_OVEN_INT_HI"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer oven integrator
high word, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_SIL_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_SIL_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_SHLD_INT_LO"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer shiled integrator
low word, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_SIH_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_SIH_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_SHLD_INT_LO"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer shield integrator
high word, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_MOV_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_MOV_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_OVEN_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Oven voltage, in
DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_MOC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_MOC_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_OVEN_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Oven current, in
DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_MSV_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_MSV_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_SHLD_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Shield voltage, in
DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_MSC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_MSC_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_SHLD_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Shield current, in
DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_MMP_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_MMP_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_MANIFOLD_PRES"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer manifold pressure,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_MOE_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_MOE_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_OVEN_ERR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Oven error, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_MSE_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_MSE_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_SHLD_ERR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Shield error, in
DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_MTW_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_MTW_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_T_WIDTH"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer T heater pulse
width, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_MOW_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_MOW_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_OVEN_WIDTH"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Oven pulse width,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_ME_MSW_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_ME_MSW_20080501_U1.DAT"
PRODUCT_TYPE = "MEM_SHLD_WIDTH"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer shield pulse width,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_C1D_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_C1D_20080501_U1.DAT"
PRODUCT_TYPE = "COVER1_DONE"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Cover 1 and
Puncture 1 end of stroke indicator,
in binary."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_TA_C2D_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_TA_C2D_20080501_U1.DAT"
PRODUCT_TYPE = "COVER2_DONE"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Thermal Analyzer Cover 2 and
Puncture 2 end of stroke indicator,
in binary."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_ESB_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_ESB_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_STATUS_BITS"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer status, in
bits."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_ETC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_ETC_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_TRAP_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer trap current,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_EEC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_EEC_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_EMISSION_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer emission
current, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_EF1_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_EF1_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_FILAMENT_1"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer filament 1,
boolean."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_EF2_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_EF2_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_FILAMENT_2"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer filament 2,
boolean."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_EP5_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_EP5_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_PLUS_5_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer plus 5 voltage,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_EP2_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_EP2_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_PLUS_12_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer plus 12
voltage, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_M12_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_M12_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_MINUS_12_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer minus 12
voltage, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_FC1_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_FC1_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_FILAMENT_CUR_1"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer filament 1
current, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_FC2_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_FC2_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_FILAMENT_CUR_2"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer filament 2
current, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_EMV_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_EMV_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_MULTIPIER_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer multipier
voltage, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_EIV_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_EIV_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_ION_PUMP_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer ion pump
voltage, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_EIC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_EIC_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_ION_PUMP_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer ion pump
current, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_ESV_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_ESV_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_SWEEP_VOLT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer sweep voltage,
in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_EGC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_EGC_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_GEC_CUR"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer gas enrichment
cell current, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_M1T_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_M1T_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_MAGNET_TEMP_1"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer magnet 1
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_M2T_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_M2T_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_MAGNET_2_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer magnet 2
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_ECT_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_ECT_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_PROC_TEMP"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer processor
temperature, in DN."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_EAC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_EAC_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_AVG_CALLS"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer average times
through background task per second,
in counts."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
OBJECT = FILE
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 14
FILE_RECORDS = 1000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EG_EMC_20080501_U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
PRODUCT_ID = "TS020EDR_EG_EMC_20080501_U1.DAT"
PRODUCT_TYPE = "EGA_MIN_CALLS"
/* DESCRIPTIVE data elements */
DESCRIPTION = "Evolved Gas Analyzer minimum calls
per second, in counts."
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 1000
ROW_BYTES = 14
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
/* The complete column definitions are contained in an */
/* externalfile found in the LABEL directory of the archive */
/* disk. */
COLUMNS = 3
^STRUCTURE = "TEGA_ENG.FMT"
END_OBJECT = TIME_SERIES
END_OBJECT = FILE
END
PDS_VERSION_ID = PDS3
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 3978
FILE_RECORDS = 50
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR__SC_2008_05_01__U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
DATA_SET_NAME = "PHX MARS THERMAL EVOLVED GAS
ANALYZER 1 EDR V1.0"
DATA_SET_ID = "PHX-M-TEGA-1-EDR-V1.0"
PRODUCT_ID = "TS030EDR__SC_2008_05_01__U1"
PRODUCT_TYPE = "TEGA_SC"
PRODUCT_VERSION_ID = "1.0"
RELEASE_ID = "0001"
OPS_TOKEN = 16#40406720#
/* DESCRIPTIVE DATA ELEMENTS */
INSTRUMENT_HOST_NAME = "2007 MARS PHOENIX"
INSTRUMENT_NAME = "THERMAL EVOLVED GAS ANALYZER"
SPACECRAFT_ID = PHX
TARGET_NAME = MARS
MISSION_PHASE_NAME = "PRIMARY MISSION"
START_TIME = 2008-05-01T14:14:32.890
STOP_TIME = 2008-05-01T20:09:44.149
SPACECRAFT_CLOCK_START_COUNT = 208023626065
SPACECRAFT_CLOCK_STOP_COUNT = 208035731925
PRODUCT_CREATION_TIME = 2008-09-15T10:54:47.894
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 50
ROW_BYTES = 3978
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
COLUMNS = 6
^STRUCTURE = "TEGA_SC.FMT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "
"
END_OBJECT = TIME_SERIES
END
PDS_VERSION_ID = PDS3
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 3978
FILE_RECORDS = 50
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EGA_2008_05_01__U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
DATA_SET_NAME = "PHX MARS THERMAL EVOLVED GAS
ANALYZER 1 EDR V1.0"
DATA_SET_ID = "PHX-M-TEGA-1-EDR-V1.0"
PRODUCT_ID = "TS030EDR_EGA_2008_05_01__U1"
PRODUCT_TYPE = "TEGA_EGA"
PRODUCT_VERSION_ID = "1.0"
RELEASE_ID = "0001"
OPS_TOKEN = 16#40406720#
/* DESCRIPTIVE DATA ELEMENTS */
INSTRUMENT_HOST_NAME = "2007 MARS PHOENIX"
INSTRUMENT_NAME = "THERMAL EVOLVED GAS ANALYZER"
SPACECRAFT_ID = PHX
TARGET_NAME = MARS
MISSION_PHASE_NAME = "PRIMARY MISSION"
START_TIME = 2008-05-01T14:14:32.890
STOP_TIME = 2008-05-01T20:09:44.149
SPACECRAFT_CLOCK_START_COUNT = 208023626065
SPACECRAFT_CLOCK_STOP_COUNT = 208035731925
PRODUCT_CREATION_TIME = 2008-09-15T10:54:47.894
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 50
ROW_BYTES = 3978
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
COLUMNS = 6
^STRUCTURE = "TEGA_EGA.FMT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "
"
END_OBJECT = TIME_SERIES
END
PDS_VERSION_ID = PDS3
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 3978
FILE_RECORDS = 50
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_EGH_2008_05_01__U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
DATA_SET_NAME = "PHX MARS THERMAL EVOLVED GAS
ANALYZER 1 EDR V1.0"
DATA_SET_ID = "PHX-M-TEGA-1-EDR-V1.0"
PRODUCT_ID = "TS030EDR_EGH_2008_05_01__U1"
PRODUCT_TYPE = "TEGA_EGH"
PRODUCT_VERSION_ID = "1.0"
RELEASE_ID = "0001"
OPS_TOKEN = 16#40406720#
/* DESCRIPTIVE DATA ELEMENTS */
INSTRUMENT_HOST_NAME = "2007 MARS PHOENIX"
INSTRUMENT_NAME = "THERMAL EVOLVED GAS ANALYZER"
SPACECRAFT_ID = PHX
TARGET_NAME = MARS
MISSION_PHASE_NAME = "PRIMARY MISSION"
START_TIME = 2008-05-01T14:14:32.890
STOP_TIME = 2008-05-01T20:09:44.149
SPACECRAFT_CLOCK_START_COUNT = 208023626065
SPACECRAFT_CLOCK_STOP_COUNT = 208035731925
PRODUCT_CREATION_TIME = 2008-09-15T10:54:47.894
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 50
ROW_BYTES = 3978
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
COLUMNS = 6
^STRUCTURE = "TEGA_EGH.FMT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "
"
END_OBJECT = TIME_SERIES
END
PDS_VERSION_ID = PDS3
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 3978
FILE_RECORDS = 50
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_LED_2008_05_01__U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
DATA_SET_NAME = "PHX MARS THERMAL EVOLVED GAS
ANALYZER 1 EDR V1.0"
DATA_SET_ID = "PHX-M-TEGA-1-EDR-V1.0"
PRODUCT_ID = "TS030EDR_LED_2008_05_01__U1"
PRODUCT_TYPE = "TEGA_LED"
PRODUCT_VERSION_ID = "1.0"
RELEASE_ID = "0001"
OPS_TOKEN = 16#40406720#
/* DESCRIPTIVE DATA ELEMENTS */
INSTRUMENT_HOST_NAME = "2007 MARS PHOENIX"
INSTRUMENT_NAME = "THERMAL EVOLVED GAS ANALYZER"
SPACECRAFT_ID = PHX
TARGET_NAME = MARS
MISSION_PHASE_NAME = "PRIMARY MISSION"
START_TIME = 2008-05-01T14:14:32.890
STOP_TIME = 2008-05-01T20:09:44.149
SPACECRAFT_CLOCK_START_COUNT = 208023626065
SPACECRAFT_CLOCK_STOP_COUNT = 208035731925
PRODUCT_CREATION_TIME = 2008-09-15T10:54:47.894
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 50
ROW_BYTES = 3978
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
COLUMNS = 6
^STRUCTURE = "TEGA_LED.FMT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "
"
END_OBJECT = TIME_SERIES
END
PDS_VERSION_ID = PDS3
/* FILE CHARACTERISTICS */
RECORD_TYPE = FIXED_LENGTH
RECORD_BYTES = 140
FILE_RECORDS = 5000
/* POINTERS TO DATA OBJECTS */
^TIME_SERIES = "TS020EDR_MSG_2008_05_01__U1.DAT"
/* IDENTIFICATION DATA ELEMENTS */
DATA_SET_NAME = "PHX MARS THERMAL EVOLVED GAS
ANALYZER 1 EDR V1.0"
DATA_SET_ID = "PHX-M-TEGA-1-EDR-V1.0"
PRODUCT_ID = "TS030EDR_MSG_20080501____U1"
PRODUCT_TYPE = "TEGA_MSG"
PRODUCT_VERSION_ID = "1.0"
RELEASE_ID = "0001"
OPS_TOKEN = 16#40406720#
/* DESCRIPTIVE DATA ELEMENTS */
INSTRUMENT_HOST_NAME = "2007 MARS PHOENIX"
INSTRUMENT_NAME = "THERMAL EVOLVED GAS ANALYZER"
SPACECRAFT_ID = PHX
TARGET_NAME = MARS
MISSION_PHASE_NAME = "PRIMARY MISSION"
START_TIME = 2008-05-01T14:14:32.890
STOP_TIME = 2008-05-01T20:09:44.149
SPACECRAFT_CLOCK_START_COUNT = 208023626065
SPACECRAFT_CLOCK_STOP_COUNT = 208035731925
PRODUCT_CREATION_TIME = 2008-09-15T10:54:47.894
/* DATA OBJECT DEFINITION */
OBJECT = TIME_SERIES
INTERCHANGE_FORMAT = BINARY
ROWS = 5000
ROW_BYTES = 140
SAMPLING_PARAMETER_NAME = TIME
SAMPLING_PARAMETER_UNIT = TICKS
SAMPLING_PARAMETER_INTERVAL = "N/A"
COLUMNS = 4
^STRUCTURE = "TEGA_MSG.FMT"
/* DESCRIPTIVE data elements */
DESCRIPTION = "
Messages returned by TEGA.
Possible message id's are as follows:
0 MSG_SC_DATA_NOT_READ error, data from SC not read
1 MSG_EGA_DATA_NOT_READ error, data from MS not read
2 MSG_DATA_NOT_SENT error, data packet not sent
3 MSG_TABLE_UNKNOWN error, unknown analog table parameter
4 MSG_TABLE_SETTING error, unknown analog setting
5 MSG_TABLE_VALUE error, analog value is out of range
6 MSG_2_MANY_CMDS error, too many commands in delayed
list
7 MSG_SEQ_WONT_FIT error, command seq won't fit in delay
list
8 MSG_BAD_CHECKSUM error, bad checksum
9 MSG_NOT_READ_SCBUF error, incorrect data in sc buffer
10 MSG_NOT_READ_EGABUF error, incorrect data in ega buffer
11 MSG_CRC_EGABUF error, crc error in ega buffer
12 MSG_OLD_COMMAND error, command is old
13 MSG_ANALOG_READ_FULL error, analog read list full
14 MSG_DUMP_TOO_LONG error, requested memory dump is too
long
15 MSG_DUMP_ADDRESS error, address is out of memory range
16 MSG_UNDEF_CODE_INTER error, undefined code interrupt
17 MSG_DIV_ZERO_INTER error, divide by zero interrupt
18 MSG_INVALID_CMD error, command not in list
19 MSG_HTR_INVALID_CMD error, heater command not in list
20 MSG_VLV_INVALID_CMD error, valve command not in list
21 MSG_AKR_INVALID_CMD error, aker valve command not in list
22 MSG_EEPROM_WRITE_FAIL error, write to eeprom did not work
23 MSG_CHG_SEQ_FAILED error, updating cmd sequence failed
24 MSG_NO_CMD_IN_SEQ error, no commands in a sequence
25 MSG_COM_ERR error, communication problem
26 MSG_NOT_ADD_UTIL error, task not added to util timers
27 MSG_INVALID_INDEX error, invalid parameter index
28 MSG_FUNC_CHECKSUM error, function checksum calc failed
29 MSG_RAMP_ABORT error, ramp abortted
30 MSG_ADDR_CHECKSUM error, function address and size
31 MSG_EEPROM_NOT_ENABLED error, attmpt chng eeprom state w/o
enable
32 MSG_BAD_SEQ_NUM error, invalid sequence number
33 MSG_BAD_RAMP_SEG_NUM error, invalid ramp segment number
34 MSG_RAMP_SEG_FAILED error, invalid ramp segment number
35 MSG_NOT_PUNCT_ENABLE error, puncture not enabled
36 MSG_EGA_CMD_ARRAY_FULL error, there is no room left for ega
command
37 MSG_SC_CNT_ERR error, invalid number of SC records
38 MSG_NOT_GETTER_ENABLE error, getter is not enabled
39 MSG_GETTER_ON error, getter is on when trying to
disable
40 MSG_UNKNOWN_EGA_DATA error, data rcv from EGA is unknown
type
41 MSG_ALREADY_RAMP error, can't fill oven when baking
already
42 MSG_NO_LED_DIFF error, no diff between light and dark
43 MSG_UNKNOWN_OVEN error, incorrect oven number selected
44 MSG_UNKNOWN_PWR error, unknown number from dma
register
45 MSG_CMD_NOT_FOUND error, command not in delayed list
46 MSG_BAD_EGA_REQ error, unknown request from EGA
47 MSG_INVALID_SEQ error, request to exec invalid
sequence
48 MSG_ANALOG_READ_NO_ADD error, analog read list full
70 MSG_RAM_CHECK_FAIL error, RAM check failed
71 MSG_FSW_EEPROM_CHECK_FAIL error, FSW EEPROM checksum check
failed
72 MSG_MINI_MEM_CHECK_FAIL error, found error in mini memory
check
73 MSG_NOT_LOADER_CMD error, valid cmd but not handled by
loader
74 MSG_INVALID_MEM_ADDRESS error, invalid memory
75 MSG_BAD_SIDE_PATTERN error, bad side pattern
76 MSG_LDR_FSW_UNAVAIL ldr doesn't recognize FSW jump
instruction
77 MSG_RAM_WRITE_OVER memload starts in RAM spills into
EEPROM
78 MSG_LDR_CP_EEP_INVALID Invalid RAM/EE address in FSW func
table
79 MSG_FSW_FGV_TBL_INVALID Invalid FSW func table entries
80 MAX_ERR_MSG end of error messages
81 MSG_TABLE_CHANGE analog table has been changed
82 MSG_SC_TIME1 spacecraft time was sent
83 MSG_SC_TIME2 spacecraft time was sent
84 MSG_CMD_DONE command has been executed
85 MSG_INTER_CNT number of times and interrupt has been
run
86 MSG_VERSION current fsw version
87 MSG_ADDED_DELAYED cmd added to delayed list
88 MSG_SHUTDOWN shutdown command received from S/C
89 MSG_HEARTBEAT the number of hearbeat sent so far
90 MSG_ACTION_COMPLETE a delayed action has been completed
91 MSG_POWER_CHANGE heater power changed
92 MSG_VALVE_CHANGE valve state changed
93 MSG_AKER_CHANGE aker valve state changed
94 MSG_SEQ_EXEC a sequence is being executed
95 MSG_PARAM_CHANGE parameter has been changed
96 MSG_EGA_TIME ega/peb time synch
97 MSG_SWITCH_TO_SLOW LED collection switched to slow rate
98 MSG_OVEN_FULL OVEN full indicator true
99 MSG_OVEN_NOT_FULL OVEN full indicator false
100 MSG_EGA_REQ request received from EGA
101 MSG_START_RAMP_TEMP starting ramp temps
102 MSG_EGA_CMD_ARRAY_ADD added ega command to command queue
103 MSG_EGA_CMD_ARRAY_SEND sent ega command from command queue
130 MSG_FSW_EEPROM_PASSED ldr passed FSW EEPROM checksum
checking
131 MSG_LDR_MEM_PASSED ldr passed memory checking
132 MSG_LDR_INIT_DONE ldr finished initialization
133 MSG_LDR_CHECKPOINT ldr checkpoint message (for debugging)
150 MSG_EGA_CMD_DONE ega command was executed
151 MSG_EGA_COM_ERROR ega communication error
152 MSG_EGA_COM_RPT ega communication report
153 MSG_EGA_FPGA_EE0_VER ega version numbers for FPGA & EE0
154 MSG_EGA_PROM_EE1_VER ega version numbers for PROM & EE1
155 MSG_EGA_SUPER_MODE ega mode deleted from super mode
156 MSG_EGA_MODE_TABLE ega mode table ID
157 MSG_EGA_MAGNETIC ega base magnetic field
158 MSG_EGA_CALIBRATION ega calibration results
159 MSG_EGA_INFO ega informational
160 MSG_EGA_UNK_CMD ega error, unknown command
161 MSG_EGA_BAD_CONST ega error, bad constant location
162 MSG_EGA_CRC_RAM_ERR ega error, CRC error on RAM device
163 MSG_EGA_CRC_LOC ega error, CRC location error
164 MSG_EGA_ILL_MODE ega error, illegal mode
165 MSG_EGA_UNK_MODE ega error, unknown mode
166 MSG_EGA_UNK_MASS ega error, undefined mass
167 MSG_EGA_EEPROM_FAIL ega error, EEPROM programing failure
168 MSG_EGA_CRC_CMD_ERR ega error, CRC error on command
169 MSG_EGA_UNDEF_MODE ega error, undefined mode
170 MSG_EGA_INCOMP_MODE ega error, incomplete mode
171 MSG_EGA_ERR_MODE ega error, mode error
172 MSG_EGA_ERR_FATAL ega error, fatal
173 MSG_EGA_ERR_SERIOUS ega error, serious
"
END_OBJECT = TIME_SERIES
END
EGA_REC.FMT
OBJECT = COLUMN
COLUMN_NUMBER = 1
NAME = VOLTAGE
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 2
START_BYTE = 1
DESCRIPTION = "voltage during this set of readings"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = COUNTS1
COLUMN_NUMBER = 2
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 3
DESCRIPTION = "counts at sensor 1"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = COUNTS2
COLUMN_NUMBER = 3
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 7
DESCRIPTION = "counts at sensor 2"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = COUNTS3
COLUMN_NUMBER = 4
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 11
DESCRIPTION = "counts at sensor 3"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = COUNTS4
COLUMN_NUMBER = 5
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 15
DESCRIPTION = "counts at sensor 4"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = DWELL_TIME
COLUMN_NUMBER = 6
BYTES = 2
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 19
DESCRIPTION = "dwell time at this voltage"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = MODE
COLUMN_NUMBER = 7
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 21
DESCRIPTION = "mode number and EEPROM side mode is from"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = PARAMS
COLUMN_NUMBER = 8
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 22
DESCRIPTION = "emission energy and emission level"
END_OBJECT = COLUMN
EGH_REC.FMT
OBJECT = COLUMN
COLUMN_NUMBER = 1
NAME = VOLTAGE
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 2
START_BYTE = 1
DESCRIPTION = "voltage during this set of readings"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = COUNTS
COLUMN_NUMBER = 2
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 3
DESCRIPTION = "counts at sensor"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = DWELL_TIME
COLUMN_NUMBER = 3
BYTES = 2
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 7
DESCRIPTION = "dwell time at this voltage"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = MODE
COLUMN_NUMBER = 4
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 9
DESCRIPTION = "mode number an EEPROM side mode is from"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = PARAMS
COLUMN_NUMBER = 5
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 10
DESCRIPTION = "emission energy and emission level"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = CHANNEL
COLUMN_NUMBER = 6
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 11
DESCRIPTION = "channel counts are taken from"
END_OBJECT = COLUMN
SC_REC.FMT
OBJECT = COLUMN
COLUMN_NUMBER = 1
NAME = OVEN_RAMP
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 2
START_BYTE = 1
DESCRIPTION = "oven ramp average over readings in this period"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SHIELD_RAMP
COLUMN_NUMBER = 2
BYTES = 2
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 3
DESCRIPTION = "shield ramp average over readings in this period"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = T_HTR_RAMP
COLUMN_NUMBER = 3
BYTES = 2
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 5
DESCRIPTION = "T heater ramp average over readings in this period"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = OVEN_PULSE
COLUMN_NUMBER = 4
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 7
DESCRIPTION = "oven pulse"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SHIELD_PULSE
COLUMN_NUMBER = 5
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 11
DESCRIPTION = "shield pulse"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = OVEN_PWR_LO
COLUMN_NUMBER = 6
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 15
DESCRIPTION = "oven power low word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = OVEN_PWR_HI
COLUMN_NUMBER = 7
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 19
DESCRIPTION = "oven power high word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = OVEN_CUR_LO
COLUMN_NUMBER = 8
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 23
DESCRIPTION = "oven current low word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = OVEN_CUR_HI
COLUMN_NUMBER = 9
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 27
DESCRIPTION = "oven current high word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = OVEN_VOLT_LO
COLUMN_NUMBER = 10
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 31
DESCRIPTION = "oven voltage low word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = OVEN_VOLT_HI
COLUMN_NUMBER = 11
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 35
DESCRIPTION = "oven voltage high word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SHIELD_PWR_LO
COLUMN_NUMBER = 12
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 39
DESCRIPTION = "shield power low word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SHIELD_PWR_HI
COLUMN_NUMBER = 13
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 43
DESCRIPTION = "shield power high word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SHIELD_CUR_LO
COLUMN_NUMBER = 14
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 47
DESCRIPTION = "shield current low word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SHIELD_CUR_HI
COLUMN_NUMBER = 15
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 51
DESCRIPTION = "shield current high word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SHIELD_VOLT_LO
COLUMN_NUMBER = 16
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 55
DESCRIPTION = "shield voltage low word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = SHIELD_VOLT_HI
COLUMN_NUMBER = 17
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 59
DESCRIPTION = "shield voltage high word"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = DSC_TIME
COLUMN_NUMBER = 18
BYTES = 4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 63
DESCRIPTION = "TEGA time when set was summed"
END_OBJECT = COLUMN
LED_REC.FMT
OBJECT = COLUMN
COLUMN_NUMBER = 1
NAME = READING_TYPE
DATA_TYPE = MSB_UNSIGNED_INTEGER
BYTES = 1
START_BYTE = 1
DESCRIPTION = "type of reading, raw (43) or integrated (42)"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = READ_TIME
COLUMN_NUMBER = 2
BYTES = 1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 2
DESCRIPTION = "low byte of the TEGA clock"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = READING_VAL
COLUMN_NUMBER = 3
BYTES = 2
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 3
DESCRIPTION = "The value of the sensor"
END_OBJECT = COLUMN