urn:nasa:pds:xas_synthesized_glasses:data:cr_xas_j062
1.0
Cr XAS Spectra of Synthesized Glass Sample J062
1.17.0.0
Product_Observational
2021-07-13
1.0
Initial version.
2018-02-10Z
2018-02-13Z
Science
Partially Processed
Investigation of XAS Spectra of Synthesized Glasses
Individual Investigation
urn:nasa:pds:context:investigation:individual.xas_synthesized_glasses
data_to_investigation
Advanced Photon Source
Host
urn:nasa:pds:context:facility:laboratory.aps
is_facility
Beamline 13-ID-E (with Si311 Detector)
Instrument
urn:nasa:pds:context:instrument:aps.beamline13ide
is_instrument
J062
Laboratory Analog
J062
Glass Sample J062
Sample J062: SiO2 wt% = 49.1, Mg# = 67.6, Na2O+K2O = 2.0
Y
Laboratory Sample
The University of Tennessee, Knoxville, Department of Earth and Planetary Sciences
Molly McCanta
Synthetic Sample
Synthetic
Entirely Synthetic
Solid
Inorganic
Amorphous
Nonparticulate
1
1
Beamline 13-ID-E (with Si311 Detector)
urn:nasa:pds:context:instrument:aps.beamline13ide
is_instrument
X-Ray Absorption Near-Edge Structure
Energy
5909
6203
eV
Molly McCanta
Molly McCanta
66
10.2138/am-2016-5555
M. Darby Dyar, Molly McCanta, Elly Breves, C.J. Carey, Antonio Lanzirotti, Accurate predictions
of iron redox state in silicate glasses: A multivariate approach using X-ray absorption spectroscopy,
American Mineralogist, 101(3): 744–747, doi: https://doi.org/10.2138/am-2016-5555.
cr_xas_j062.csv
2021-07-13
0
40
7-Bit ASCII Text
The first row of the table contains column headings.
40
PDS DSV 1
449
Carriage-Return Line-Feed
Comma
4
0
Spectral Energy
1
ASCII_Real
Electron Volts
Cr Run 1 Normalized Intensity
2
ASCII_Real
Normalized intensity of sample J062 Cr analysis 1.
Cr Run 2 Normalized Intensity
3
ASCII_Real
Normalized intensity of sample J062 Cr analysis 2.
Cr Run 3 Normalized Intensity
4
ASCII_Real
Normalized intensity of sample J062 Cr analysis 3.